Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 65 for “"Resistance to fracture"”
-
Resistance to Fracture of 0.018-Inch Slot Ceramic Brackets with Bucco-Lingual Torque
With the introduction of ceramic brackets to orthodontics many clinicians have met with frustration when attempting torquing movements of the dentition treated with ceramic brackets. The occurrence of ceramic bracket fracture from archwire torsion has been deemed excessive. The purpose of this …
-
SODIUM HYPOCHLORITE'S EFFECT ON NICKEL-TITANIUM ROTARY INSTRUMENTS AND ITS EFFECT ON RESISTANCE TO FRACTURE
The purpose of this study was to examine the effect of partial and total immersion in sodium hypochlorite on nickel-titanium rotary files and to determine whether resistance to fracture was influenced by the immersion time. One hundred K3 and 100 ProFile® rotary files were either partially or …
-
The Effect of Sodium Hypochlorite on Nickel Titanium Rotary Instruments and its Effect on Resistance to Fracture
The purpose of this study was to examine the effect of immersion in sodium hypochlorite on nickel titanium rotary files and determine whether resistance to fracture was influenced by the immersion time. 70 ISO size 25 0.04 taper nickel titanium K3 and Profile rotary instruments were immersed in …
-
A COMPARISON OF RESISTANCE TO FRACTURE AND DEFORMATION BETWEEN ONE AND TWO-PIECE SMALL DIAMETER DENTAL IMPLANTS
… diameter dental implants have been developed to overcome clinical settings of limited bone and dental spacing. These small diameter implants are available as a two-piece implant and prosthetic abutment or a one-piece implant. A concern with small diameter implants is an increased …
-
Long-term stability and resistance to fracture: Different abutments of the SIC implant system in the artificial mouth
Abstract<br>Objective<br>To investigate the survival rate, fracture strength, bending moments, loading to fracture and fracture modes of different designs of zirconia abutments after dynamic loading with thermocycling, and compare these values to titanium abutments.<br><br>Methods<br>A total of 80 …
-
Peculiarities of ultrastructure of tooth root canals treated with resorcinol formaldehyde resin, evaluation of influence of endodontic retreatment procedures and resistance to fracture. Study in vitro /
… Consequently, dentists are still struggling to resolve endodontic retreatment problems related to the use of this material in clinical practice. The present study gives an in-depth analysis of the overall impact of the combination of both machine-driven and ultrasound instruments on root …
-
Mechanical resistance to fracture of narrow platform dental implants with hexagonal external connection submitted to implantoplasty with different bone levels and crown/implant ratios. An in vitro study.
… INTRODUCTION: Peri-implantitis is an inflammatory condition that affects soft and hard tissues around dental implants and that can lead to implant failure. Implantoplasty is a procedure that allows implant surface decontamination by removing the implant threads and smoothening its surface, …
-
Stress Analysis of Post and Crown Restorations of Endodontically Treated Teeth
… lateral incisor teeth were randomly divided into four equal groups to test their resistance to fracture. Group 1 teeth were the controls, no treatment was done. Group 2 teeth consisted of endodontically treated teeth, restored with composite resin in the access opening. Group 3 teeth were …
-
Thermal shock resistance parameters for the industrial lining problem
… heating rate thermoelastic model has been used to develop design and selection criteria for refractory components of linings of high-temperature furnaces and process vessels. The criteria are in the form of resistance to fracture initiation and resistance to damage parameters which account for …
-
The Effect of NaOCl, Ca(OH)2, MTA and MTAD on Root Dentin Fracture Resistance
… of immature teeth that have been subjected to trauma or decay. It is not well established what effect these materials may have on the immature root dentin. A concern would be the resistance to fracture of the remaining root dentin. The purpose of this study was to compare the resistance of …
-
Fracture Resistance of Immature Permanent Incisors using a Pendulum Impact Device
Introduction:Traumatic injuries to immature permanent teeth that lead to pulpal necrosis present a unique clinical challenge. These teeth are left with thin root walls which are susceptible to fracture. Attempts to fortify these roots include obturation with restorative materials or regenerative …
-
Experimental study of deformation and microcracking in human cortical bone
… bone is a complex biological material with up to seven levels of hierarchical structure. Due to this complexity, it is still not fully understood how the various structures contribute to the macroscopic mechanical response. Such understanding is important to assess the mechanical contributions …
-
COMPARISON OF FRACTURE RESISTANCE BETWEEN TRADITIONAL ENDODONTIC ACCESS AND MINIMAL ENDODONTIC ACCESS IN 3D-PRINTED MANDIBULAR FIRST MOLARS
… (TEA), which involves a straight-line access to root canals and a complete removal of the roof of the pulp chamber, whereas others advocate the minimal endodontic access (MEA) to minimize the removal of tooth structure. Several studies have compared the fracture resistance of TEA to that of …
-
Rezorcino formalinu gydytų dantų šaknų kanalų ultrastruktūros ypatumai, endodontinio pergydymo procedūrų poveikio ir atsparumo skilimui vertinimas. Tyrimas in vitro /
… Consequently, dentists are still struggling to resolve endodontic retreatment problems related to the use of this material in clinical practice. The present study gives an in-depth analysis of the overall impact of the combination of both machine-driven and ultrasound instruments on root …
-
Estudo da viabilidade do processo de reciclagem do material descartado do sistema Zirkonzanh® de produção de próteses dentárias
… the machining of blocks of zirconia in the laboratory to prepare the various types of prostheses, much of the material is given off in the form of powder, which is subsequently discarded. The waste of this material results in financial loss, reflecting higher final cost treatment for patients, as …
-
Efeitos do treinamento resistido na morfologia, propriedades e marcadores de remodelamento de matriz extracelular óssea em modelo de ratas ovariectomizadas
Absence of estrogen on menopause leads to detrimental consequences, including osteoporosis, which is characterized by unbalanced bone extracellular matrix (ECM) remodeling. Bone resistance to fracture is related to bone mass, structure and architecture including bone ECM changes. Resistance …
-
Development Of Hybrid Coating Materials To Improve The Success Of Titanium Implants
… titanium (Ti) and its alloys have become ubiquitous within implantology as materials to restore or augment the function of human tissues, their success is plagued by complications associated with infection and aseptic implant loosening. These two risks account for the majority of implant …
-
An In-Vitro Study Evaluating the Fracture Resistance and Insertion Torque of Self-Drilling Mini-Implants Upon Insertion Into Synthetic High Density Mandibular Bone.
… but there is little information regarding their fracture resistance in areas of high density bone without pre-drilling. Purpose: To determine the peak fracture torques of six commonly used self-drilling mini-implants, and to examine how each performs in extreme conditions without pre-drilling. …
-
Characterization of bone structural, geometric, and material properties in the TallyHO mouse model of type 2 diabetes mellitus
Patients with type 2 diabetes (T2DM) have higher fracture risk compared to patients without T2DM despite having comparable to higher bone mineral density (BMD). Thus, T2DM might alter other aspects of resistance to fracture beyond BMD such as bone geometry, microarchitecture, and tissue material …
Page 1 of 4