Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 203 for “"Resolving Power"”.

  1. Spatial Vision in Birds: Anatomical investigation of spatial resolving power

    Avian eyes are big both in relative and absolute terms, thus the importance of vision to birds is obvious. Even though the general eye plan is rather conservative throughout the group, there is a great variation in visual capabilities. In this thesis I present four studies on different aspects of …

    lund Repository record for Spatial Vision in Birds: Anatomical investigation of spatial resolving power (opens in a new tab) Download PDF for Spatial Vision in Birds: Anatomical investigation of spatial resolving power (opens in a new tab)

  2. Design and construction of a medium resolving, power scanning, grating spectrometer

    … Future work includes optimization of the resolving power and of the fore optics. Upon completion, the spectrometer will prove to be a very useful instructional aid in the optics and optoelectronics classes taught at the school, and as a medium resolving power visible and near ultraviolet …

    nps Repository record for Design and construction of a medium resolving, power scanning, grating spectrometer (opens in a new tab)

  3. Magnetic field study for a new generation high resolution mass separator

    … The required separation is expressed in terms of resolving power defined as the inverse of the relative mass difference between two isotopes that need to be separated. The higher the mass the greater the resolving power required. The challenge is the separation of two isobars rather than two …

    ubc Repository record for Magnetic field study for a new generation high resolution mass separator (opens in a new tab) Download PDF for Magnetic field study for a new generation high resolution mass separator (opens in a new tab)

  4. The effect of structuring aids on the quality and quantity of solutions generated to ill-structured problems: A comparison of expert and novice performance

    … structuring aid, objectives, on the quantity and resolving power of solutions to ill-structured problems generated by experts and novices. Resolving power was defined as the extent to which a problem solution resolved conflicting facets of the problem. The expert subjects were 57 MBA students, the …

    nebraska Repository record for The effect of structuring aids on the quality and quantity of solutions generated to ill-structured problems: A comparison of expert and novice performance (opens in a new tab)

  5. Development of Ion Mirror and Detection Region Configurations for Distance-of-Flight Mass Spectrometry

    … used in glow discharge (GD)-DOFMS. Mass resolving power attained in DOFMS is governed by the fact that ions of the same m/z will possess a range of initial energies at the start of the experiment. If left uncorrected, differences in initial energy will lead to different flight distances, …

    buffalo Repository record for Development of Ion Mirror and Detection Region Configurations for Distance-of-Flight Mass Spectrometry (opens in a new tab)

  6. Design and Development of an Electrospray Ionization Zoom Time-of-Flight Mass Spectrometer

    … full mass spectral coverage with modest mass resolving power, while the CMA-TOFMS mode offers enhanced mass resolving power over a narrow mass range. Constant momentum acceleration is confirmed experimentally using retarding potential analysis (RPA). RPA is also used to estimate the initial …

    buffalo Repository record for Design and Development of an Electrospray Ionization Zoom Time-of-Flight Mass Spectrometer (opens in a new tab)

  7. Massenspektrometrische Untersuchungen und Simulationen zur Verbesserung des Auflösungsvermögens und der Weiterentwicklung einer Cassini-Ionenfalle

    … working Cas-sinian ion traps and increasing its resolving power. To achieve this goal the capabilities and characteristics of the existing design need to be evaluated. The first part of this work presents the results of this characterization by determining the ideal setup and by giving examples …

    cau-kiel Repository record for Massenspektrometrische Untersuchungen und Simulationen zur Verbesserung des Auflösungsvermögens und der Weiterentwicklung einer Cassini-Ionenfalle (opens in a new tab)

  8. Integration of a multi reflection time of flight isobar separator into the TITAN experiment at TRIUMF

    … MR-ToF internal ion source to demonstrate the resolving power of the MR-ToF. Mass measurements were performed at a resolving power of 200 000, exceeding performance expectations by a factor of 2. Isobar separation was used to remove either Ar or K, requiring a mass resolving power ≥ 25 000. The …

    ubc Repository record for Integration of a multi reflection time of flight isobar separator into the TITAN experiment at TRIUMF (opens in a new tab) Download PDF for Integration of a multi reflection time of flight isobar separator into the TITAN experiment at TRIUMF (opens in a new tab)

  9. Re-evaluation of reflection seismology for archaeological investigation

    … methods were inappropriate due to restricted resolving power and the relatively small-scale nature of archaeological features. Unfortunately, this self-fulfilling prophesy endures and has largely discouraged subsequent attempts to exploit seismic methods for archaeological reconnaissance. …

    ubc Repository record for Re-evaluation of reflection seismology for archaeological investigation (opens in a new tab) Download PDF for Re-evaluation of reflection seismology for archaeological investigation (opens in a new tab)

  10. Design and Construction of a Vacuum-Grating Spectrograph for the Infrared

    … possible without restricting the versatility and resolving power of the instruments. The plan was to construct parts for both single and double pass instruments in so far as the parts were alike, and then to complete the single pass instrument and determine its characteristics before completing …

    utk-theses Repository record for Design and Construction of a Vacuum-Grating Spectrograph for the Infrared (opens in a new tab)

  11. NARROW OPEN TUBULAR LIQUID CHROMATOGRAPHY: SEPARATION OPTIMIZATION AND COLUMN IMPROVEMENT

    … encountered an unprecedented demand for enhanced resolving power and lower detection level. Open tubular (OT) column had been theoretically predicted to offer the greatest potential for extremely high separation efficiency in LC and produce superior resolving power in the bioanalytical studies …

    oklahoma-thes Repository record for NARROW OPEN TUBULAR LIQUID CHROMATOGRAPHY: SEPARATION OPTIMIZATION AND COLUMN IMPROVEMENT (opens in a new tab)

  12. A Fresnel Half-Period Zone Plate for Focusing Electromagnetic Energy in the One Meter Wave-Length Region

    … of zones in a given aperture, (3) and that the resolving power is a function of the aperture dimension and of the wavelength of the radiation.

    unm Repository record for A Fresnel Half-Period Zone Plate for Focusing Electromagnetic Energy in the One Meter Wave-Length Region (opens in a new tab)

  13. Atomic Masses and Neutron Separation Energies for Some Isotopes of Cadmium

    … mass spectrometer operating at its theoretical resolving power of more than 100,000 at the base of the peaks has been used to measure five mass spectral doublets. The resulting single and double neutron separation energies for some cadmium nuclides are much more precise than those from previous …

    mcmaster Repository record for Atomic Masses and Neutron Separation Energies for Some Isotopes of Cadmium (opens in a new tab)

  14. SI3N4/SIO2 ARRAYED WAVEGUIDE GRATINGS AND PEROVSKITE BASED SOLAR CELLS

    … the lengths of arrayed waveguides. For a lower resolving power design with V-shaped structure, the peak transmission reaches -1.9 dB and the highest resolving power is around 5,300. For the higher resolving power design with crossover structure, the peak transmission is -2.0 dB and the maximum …

    maryland Repository record for SI3N4/SIO2 ARRAYED WAVEGUIDE GRATINGS AND PEROVSKITE BASED SOLAR CELLS (opens in a new tab)

  15. An Experimental Investigation of the Dead Time of Geiger-Mueller Counters

    … Counters, especially in cosmic ray research, the resolving power of these instruments assumes an ever increasing importance. With the present perfection of electronic circuitry, this resolving time has become largely a function of the dead time of the Geiger counter tube itself. It was therefore …

    unm Repository record for An Experimental Investigation of the Dead Time of Geiger-Mueller Counters (opens in a new tab)

  16. A Soft X-Ray Emission Endstation for the Canadian Light Source

    … Rowland circle geometry to achieve a theoretical resolving power in excess of 2,500 in our range of interest. In addition, a novel optical design for a larger extremely high resolution spectrometer has been completed to provide theoretical resolving powers exceeding 10,000 throughout the higher …

    sask Repository record for A Soft X-Ray Emission Endstation for the Canadian Light Source (opens in a new tab)

  17. Multiframe restoration methods for image synthesis and recovery

    … short-exposure images to improve the resolving power of estimation algorithms. Specifically, we examine the performance of using frame selection to extract the least degraded subset of images from an ensemble for processing. Several measures of image quality are compared against …

    arizona-thes Repository record for Multiframe restoration methods for image synthesis and recovery (opens in a new tab)

  18. Axial alignment in a ring-collection beta-ray spectrometer

    … noticeably poorer performance. Using a gathering power of .70%, a resolving power of .94% was obtained for the 661.6 Kev. K-conversion peak of Cs ¹³⁷.

    ubc Repository record for Axial alignment in a ring-collection beta-ray spectrometer (opens in a new tab) Download PDF for Axial alignment in a ring-collection beta-ray spectrometer (opens in a new tab)

Page 1 of 11