Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 18 of 18 for “"Resonance frequency analysis"”.

  1. Resonance Frequency Analysis as a Determinant of Implant Initial Stability

    … insertion resistance torque and post-insertion resonance frequency are currently the only objective methods of measurement establishing initial stability. Purpose: A study was designed to measure resonance frequency of root form dental implants placed in cadaver jaws. The resonance frequency …

    loma-linda Repository record for Resonance Frequency Analysis as a Determinant of Implant Initial Stability (opens in a new tab)

  2. Correlation Of Preoperative Analysis Of Cbct Gray Value With Implant Primary Stability

    … by measuring insertion torque value (ITV) and Resonance Frequency Analysis (ISQ). Materials and Methods: Thirty-eight patients planned to receive a total of 102 dental implants (Straumann Bone Level Tapered) were enrolled in the study. At time of implant placement, ITV in Ncm with a Bien-Air …

    uab Repository record for Correlation Of Preoperative Analysis Of Cbct Gray Value With Implant Primary Stability (opens in a new tab)

  3. Assessing the Initial Primary Stability of Dental Implants via Various Osteotomy Preparation Techniques: An Ex Vivo Comparative Study Utilizing Two Distinct Non-Invasive Methods

    … Periotest® (Siemens AG, Bensheim, Germany) and resonance frequency analysis (RFA) (Osstell Mentor) (Integration Diagnostics AB, Göteborg, Sweden) have been introduced to measure implant primary stability. The aim of this study is to assess and compare the primary stability of dental implants …

    buffalo Repository record for Assessing the Initial Primary Stability of Dental Implants via Various Osteotomy Preparation Techniques: An Ex Vivo Comparative Study Utilizing Two Distinct Non-Invasive Methods (opens in a new tab)

  4. Assessment of Alveolar Bone Density Using Implant Insertion Resistance Torque

    … Fixture stabilization can be measured by resonance frequency analysis or implant insertion resistance torque measurement. The aim of this study is to correlate pre-operative radiographic bone density to implant insertion resistance torque in human cadaver jaw bone. Materials & Methods: …

    loma-linda Repository record for Assessment of Alveolar Bone Density Using Implant Insertion Resistance Torque (opens in a new tab)

  5. Assessment and Interpretation of Dental Implant Stability: A Narrative Review and Prospective Cohort Study

    Resonance frequency analysis, which is commonly recorded as the implant stability quotient (ISQ), provides a non-invasive method for monitoring implant stability over time. Previous studies have suggested that insertion torque, bone density, implant design, and healing duration may influence ISQ …

    penn Repository record for Assessment and Interpretation of Dental Implant Stability: A Narrative Review and Prospective Cohort Study (opens in a new tab)

  6. Relationship between Implant Geometry and Primary Stability in Variant Bone Densities: An In Vitro Pilot Study

    … and primary stability was measured using resonance frequency analysis (RFA) through the Implant Stability Quotient (ISQ). Descriptive statistics and a two-way ANOVA were applied to assess the main effects of implant geometry and bone density on primary stability, as well as their …

    buffalo Repository record for Relationship between Implant Geometry and Primary Stability in Variant Bone Densities: An In Vitro Pilot Study (opens in a new tab)

  7. The Effect of Using Worn Osseodensification Drills on Bone An Ex-Vivo Study

    … and primary implant stability measured with resonance frequency analysis. A non-inferiority study design was utilized, with preset clinically acceptable margins. (2.0°C, 4.0s, 0.2mm, 5 ISQ). The t-test was conducted for the outcome of temperature, and time-to-complete, whereas the …

    tamu Repository record for The Effect of Using Worn Osseodensification Drills on Bone An Ex-Vivo Study (opens in a new tab)

  8. The Osseointegration of Magnesium Oxidized Implant

    … Implant stability was estimated by RFA (Resonance frequency analysis) method in installation to 2, 4 & 6 weeks. Statistical analyses of RFA values were performed with time and between groups using repeated measure ANOVA and turkey's multiple comparison test. After healing time of 6 weeks, …

    ajou Repository record for The Osseointegration of Magnesium Oxidized Implant (opens in a new tab) Embargoed until 9999-12-31

  9. Vergleich von zwei modifizierten dentalen Titanoberflächen mit gleichem Makrodesign im Hinblick auf ihre osseointegrativen Eigenschaften : eine histologische und biomechanische Analyse im Schafmodell

    … was measured after 0, 2, 4 and 8 weeks by Resonance Frequency Analysis (RFA). Both implants proved excellent quality regarding osseointegration although there were differences concerning biomechanical properties that could not be confirmed by histological assessment. Comparing the 2 …

    zurich

  10. Assessing the Effects of Lateral Orthodontic Forces on Dental Implant Stability: A Pilot Study

    … Tech implants were placed into the ribs and resonance frequency analysis (RFA) was used to measure the Implant Stability Quotient (ISQ) for each sample immediately following implant placement. ISQ is a surrogate measurement of implant stability. This served as the control values for the …

    buffalo Repository record for Assessing the Effects of Lateral Orthodontic Forces on Dental Implant Stability: A Pilot Study (opens in a new tab)

  11. Inverse analysis of dental implant systems using finite element method

    … Motivated by its application in stress analysis, finite element analysis (FEA) is used to study implant-bone structure biomechanics in this dissertation. After reviewing basic concepts/applications of FEA in implant dentistry, it investigates the biomechanics of various implant designs …

    nus Repository record for Inverse analysis of dental implant systems using finite element method (opens in a new tab) Download file for Inverse analysis of dental implant systems using finite element method (opens in a new tab)

  12. Effect of a Modified Stepped Osteotomy on the Primary Stability of Dental Implants in Type D4 Bone: A Cadaver Study

    … Diagnostics AB, Goteborg, Sweden) via resonance frequency analysis. Significant differences insertion torques (IT) and Implant Stability Quotient (ISQ) were analyzed with a Wilcoxon Signed Rank Test. Correlations were analyzed with the Pearson Correlation Test.;Results. Maxillary …

    wvu Repository record for Effect of a Modified Stepped Osteotomy on the Primary Stability of Dental Implants in Type D4 Bone: A Cadaver Study (opens in a new tab)

  13. Untersuchung zur Primärstabilität zweier dentaler Implantatsysteme mittels Resonanz-Frequenz-Analyse in vivo

    Ziel: Die Primärstabilität ist besonders im Hinblick auf eine prothetische Sofortversorgung ein wichtiger Parameter für die Implantatprognose. Ziel dieser Studie war es zu überprüfen, ob die Primärstabilität gemessen anhand der Resonanz-Frequenz-Analyse (RFA) bei einem selbstschneidenden sowie …

    fu-berlin Repository record for Untersuchung zur Primärstabilität zweier dentaler Implantatsysteme mittels Resonanz-Frequenz-Analyse in vivo (opens in a new tab)

  14. Estabilidade primária de implantes imediatos em comparação com implantes instalados em áreas edêntulas : uma revisão sistemática e metanálise

    Implantes imediatos instalados em alvéolos frescos são uma opção alternativa para a instalação tardia de implantes, que visa reduzir tempo de tratamento, além de promover maior satisfação e conforto do paciente. Entretanto, em função de um aporte ósseo reduzido, alguns pré-requisitos devem ser …

    brazil-ufrgs Repository record for Estabilidade primária de implantes imediatos em comparação com implantes instalados em áreas edêntulas : uma revisão sistemática e metanálise (opens in a new tab)

  15. Ανατομική και συγκριτική μελέτη της σταθερότητας των οστεοενσωματούμενων εμφυτευμάτων των γνάθων με τη χρήση συσκευής ανάλυσης συχνότητας συντονισμού

    … device in modern times for this purpose is a resonance frequency analyzing device (OSSTELL™).The OSSTELL™ device allows the clinician to reliably measure the stability of implants during the surgical stage, the time of the osseointegration process, as well as before the final prosthetic …

    greece Repository record for Ανατομική και συγκριτική μελέτη της σταθερότητας των οστεοενσωματούμενων εμφυτευμάτων των γνάθων με τη χρήση συσκευής ανάλυσης συχνότητας συντονισμού (opens in a new tab)