Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 143 for “"Respirator"”.

  1. Toward a Respirator Control System

    Made available in DSpace on 2014-12-12T20:54:21Z (GMT). No. of bitstreams: 1 7616189.pdf: 4199070 bytes, checksum: d44d955ea9f8b6737a855d1ce04b105f (MD5) Previous issue date: 1976

    uiuc Repository record for Toward a Respirator Control System (opens in a new tab)

  2. Factors that affect respirator fit-testing programs

    Respirators are used to minimize the exposure to air contaminants. A good fit is essential for the effective functioning of a respirator. The Occupational Safety and Health Administration (OSHA) requires an annual respirator fit testing. Respirator fit can be assessed either qualitatively or …

    arizona-thes Repository record for Factors that affect respirator fit-testing programs (opens in a new tab)

  3. Simulation-based assessment for N95 filtering facepiece respirator

    N95 filtering facepiece respirators (FFRs) are most commonly used for personal protection from exposures to respirable aerosol particles. FFR comfort and fit are two important parameters for FFR designers, manufacturers, users, and standards developers. Although experimental approaches for assess …

    ttu Repository record for Simulation-based assessment for N95 filtering facepiece respirator (opens in a new tab)

  4. The B Respirator Respiratory Protection for the Bearded Man

    The news today is filled with stories of respiratory illnesses. The health risks to people are everywhere. Dangerous health situations are created by nature and they are also man made. One thing stands between people and breathing contaminated air and that is a variety of different types of dust …

    rit Repository record for The B Respirator Respiratory Protection for the Bearded Man (opens in a new tab)

  5. Quantitative Respirator Fit Testing: Probed Facepiece versus Probed Cartridge

    … Four subjects were tested on four different respirators. The respirators used were MSA & 3M full and half face respirator. Each subject performed each method five times per respirator. The results indicated no correlation between the two fit testing methods overall. However, a moderate …

    odu Repository record for Quantitative Respirator Fit Testing: Probed Facepiece versus Probed Cartridge (opens in a new tab)

  6. Performance Study of Respirator Filter Media and Wall Flow Filters

    … of ambient PM has been found to aggravate the respiratory symptoms, decrease lung functions, and increase the cardiovascular morbidity and mortality. Filtration is the dominant technique used to protect both humans and environment from the pollutants including PM and gases. Among the particle …

    vcu Repository record for Performance Study of Respirator Filter Media and Wall Flow Filters (opens in a new tab)

  7. A Model for Determining Induced Physiological Stress During Respirator Wear

    … the increased physiological effort of wearing a respiratory protective device. Specifically, the model was designed to predict the effects of varying ventilatory demands on eleven respiratory variables of the man-respirator system, breath frequency (f_b), tidal volume (V_t), inspiratory flow …

    unt Repository record for A Model for Determining Induced Physiological Stress During Respirator Wear (opens in a new tab)

  8. Penetration through the staple punctures on five N95 respirator models

    … medium reduce the protection offered by the respirators. Total penetrations were measured with the staple punctures intact and when stretching the head straps a distance equivalent to a 95% male head circumference. Filter penetration were measured by sealing the staple punctures. Aerosols of …

    usf Repository record for Penetration through the staple punctures on five N95 respirator models (opens in a new tab)

  9. Analysis of 3D facial anthropometric measurements for respirator fit outcomes

    … contextual application in the development of respirators and facemasks. More than 2,000 3D facial scans were analyzed to assess measurement reliability and the dimensions of 27 facial features. This research represents the largest sample of 3D facial anthropometrics assessed to date. The three …

    colostate Repository record for Analysis of 3D facial anthropometric measurements for respirator fit outcomes (opens in a new tab)

  10. EVALUATION OF TRANSIENT COGNITIVE CHANGES FROM MAXIMAL EXERTION AND RESPIRATOR WEAR

    A comprehensive occupational respiratory protection program is mandated by federal law to protect workers exposed to breathing hazardous atmospheres. Those wearing respirators and/or performing high-intensity physical work may endure physiological and/or psychological impairment from …

    montana Repository record for EVALUATION OF TRANSIENT COGNITIVE CHANGES FROM MAXIMAL EXERTION AND RESPIRATOR WEAR (opens in a new tab)

  11. EVALUATION OF TRANSIENT COGNITIVE CHANGES FROM MAXIMAL EXERTION AND RESPIRATOR WEAR

    A comprehensive occupational respiratory protection program is mandated by federal law to protect workers exposed to breathing hazardous atmospheres. Those wearing respirators and/or performing high-intensity physical work may endure physiological and/or psychological impairment from …

    montana-tech Repository record for EVALUATION OF TRANSIENT COGNITIVE CHANGES FROM MAXIMAL EXERTION AND RESPIRATOR WEAR (opens in a new tab)

  12. Modeling and control of a pressure-limited respirator and lung mechanics

    … vulnerable to acute, critical illness. Respiratory failure can result not only from primary lung pathology, such as pneumonia, but also as a secondary consequence of heart failure or inflammatory illness, such as sepsis or trauma. When this occurs, it is essential to support patients …

    gatech Repository record for Modeling and control of a pressure-limited respirator and lung mechanics (opens in a new tab)

  13. THE CORRELATION BETWEEN PSYCHOLOGICAL TYPE AND PERFORMANCE TIME WHILE WEARING A RESPIRATOR

    … that individuals perform better if not wearing a respirator than with wearing a respirator. This study examined the degree of performance reduction attributable to specific dominant character traits. The subjects performed on a treadmill at a constant speed and grade resulting in 80-85% of maximum …

    maryland Repository record for THE CORRELATION BETWEEN PSYCHOLOGICAL TYPE AND PERFORMANCE TIME WHILE WEARING A RESPIRATOR (opens in a new tab)

  14. Mass Flow Measurement of Gaseous Breathing Air Through the Liquid Air Pack Respirator

    The Kennedy Space Center Liquid Air Pack respirator currently uses an electronic timer to control the service life of the respirator during operation. The pre-set timer cannot sense the remaining air supply in the respirator and is not programmed to account for changes in human respiration rates. A …

    ucf Repository record for Mass Flow Measurement of Gaseous Breathing Air Through the Liquid Air Pack Respirator (opens in a new tab)

  15. Use of Spirometry for Medical Clearance and Surveillance in Occupations Requiring Respirator Use

    Medical certification of workers for respirator use is an important activity of occupational medicine health professionals. Spirometry is a diagnostic tool to evaluate respiratory distress/insufficiency that may affect respirator use. In this study, we analyzed the pulmonary function data of 337 …

    usf Repository record for Use of Spirometry for Medical Clearance and Surveillance in Occupations Requiring Respirator Use (opens in a new tab)

  16. Dental Hygiene Students Reported Physiological Symptoms Associated With Wearing an N95 Respirator Mask

    … symptoms and comfort levels while wearing an N95 respiratory mask has not been examined with dental hygienists. The purpose of this study was to investigate dental hygiene students reported physiological symptoms and comfort perception while wearing an N95 respirator mask during patient care …

    odu Repository record for Dental Hygiene Students Reported Physiological Symptoms Associated With Wearing an N95 Respirator Mask (opens in a new tab)

  17. DETERMINATION OF BREATHING RESISTANCE ACROSS ACTIVATED CARBON FIBER RESPIRATOR CARTRIDGES USING SINUSOIDAL AIRFLOW

    … are considered good alternative adsorbents in respirators because of their high adsorption capacities, light weight, and fabric form. In order to further assess such application, the pressure drop across Activated carbon fibers in respirators must be adequately low to allow comfortable …

    ecu Repository record for DETERMINATION OF BREATHING RESISTANCE ACROSS ACTIVATED CARBON FIBER RESPIRATOR CARTRIDGES USING SINUSOIDAL AIRFLOW (opens in a new tab)

Page 1 of 8