Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 22 for “"Respiratory motion correction"”

  1. Respiratory motion correction in positron emission tomography

    In this thesis, we develop a motion correction method to overcome the degradation of image quality introduced by respiratory motion in positron emission tomography (PET), so that diagnostic performance for lung cancer can be improved. Lung cancer is currently the most common cause of cancer death …

    oxford Repository record for Respiratory motion correction in positron emission tomography (opens in a new tab) Restricted access

  2. Respiratory motion correction in PET/CT imaging

    In dual modality PET-CT imaging, respiratory motion can introduce blurring in PET images and create a spatial mismatch between the PET and CT datasets. Attenuation correction errors can result from this mismatch, which can produce severe artefacts that potentially alter the clinical interpretation …

    kings Repository record for Respiratory motion correction in PET/CT imaging (opens in a new tab)

  3. PET Respiratory Motion Correction in Simultaneous PET/MR

    … Emission Tomography (PET) imaging, patient motion due to respiration can lead to artefacts and blurring, in addition to quantification errors. The integration of PET imaging with Magnetic Resonance (MR) imaging in PET/MR scanners provides spatially aligned complementary clinical information, …

    ucl Repository record for PET Respiratory Motion Correction in Simultaneous PET/MR (opens in a new tab)

  4. Patient-specific prospective respiratory motion correction in cardiovascular MRI.

    Motion in MRI is a significant issue, leading to long scan times and loss of diagnostic quality. Motion in cardiovascular MRI is especially complex, as it contains both respiratory and cardiac motion in addition to general bulk motion. Cardiac motion is effectively gated with an electrocardiogram …

    ohiolink Repository record for Patient-specific prospective respiratory motion correction in cardiovascular MRI. (opens in a new tab)

  5. Deep Learning-Based Respiratory Motion Correction for Positron Emission Tomography

    … is often compromised by artifacts caused by respiratory motion during ongoing data acquisition. These motion-related artifacts reduce spatial resolution, impair quantification accuracy, and can compromise diagnostic accuracy. In the past, different strategies have been developed to compensate …

    qucosa-diss Repository record for Deep Learning-Based Respiratory Motion Correction for Positron Emission Tomography (opens in a new tab)

  6. Assessment of New Innovations In Pet/Ct For Respiratory Motion Correction

    … However, due to the long acquisition times, respiratory motion blur is unavoidable in PET images especially in the lower lung and upper abdomen. This leads to reductions in measured radiotracer concentration and lesion detectability all of which can potentially result in incorrect management …

    uthsc Repository record for Assessment of New Innovations In Pet/Ct For Respiratory Motion Correction (opens in a new tab)

  7. Respiratory motion correction techniques in positron emission tomography/computed tomography (PET/CT) imaging

    … thesis is to design, implement, and evaluate respiratory motion correction techniques that can overcome respiratory motion artifacts in PET/CT imaging. The thesis is composed of three main sections. The first section introduces a novel approach (free-breathing amplitude gating (FBAG) …

    rice Repository record for Respiratory motion correction techniques in positron emission tomography/computed tomography (PET/CT) imaging (opens in a new tab)

  8. A control system approach to subject specific prospective respiratory motion correction in cardiac MRI

    Respiratory motion of the heart is a problem for high-resolution cardiac MRI. Diaphragmatic navigator gating with a 5mm acceptance window is most commonly used to address this but has an inherently low respiratory efficiency that is further compromised by respiratory drift. A novel method is …

    cape-town Repository record for A control system approach to subject specific prospective respiratory motion correction in cardiac MRI (opens in a new tab)

  9. Motion Field Integrated Reconstruction Using Deep Learning for MR and PET/MR Respiratory Motion Correction

    Since motion is unavoidable in clinical human imaging studies, motion correction in PET and MRI has long been of interest for the liver/lung imaging community. Respiratory motion, the most crucial source of motion in body imaging, affects thoracic organs and the upper/lower abdomen. In MRI, motion …

    wustl Repository record for Motion Field Integrated Reconstruction Using Deep Learning for MR and PET/MR Respiratory Motion Correction (opens in a new tab)

  10. Prospective Respiratory Motion Correction for Cardiac Magnetic Resonance Imaging using Machine Learning and Pilot Tone (PROMPT)

    … tissue abnormalities, and more. However, motion-induced artifacts remain a significant challenge in cardiac imaging. For patients with limited breath-holding capacity, respiratory motion correction techniques are essential for obtaining artifact-free images during free breathing. Pilot …

    ohiolink Repository record for Prospective Respiratory Motion Correction for Cardiac Magnetic Resonance Imaging using Machine Learning and Pilot Tone (PROMPT) (opens in a new tab)

  11. The impact of respiratory motion correction methods on tumour detection and quantification in Positron Emission Tomography

    Respiratory motion degrades PET spatial resolution and image quality limiting the potential benefits from increased resolution. Motion correction is complicated by limitations of the poor statistical quality of PET data and there is still not a robust method available. Motion correction can be …

    kings Repository record for The impact of respiratory motion correction methods on tumour detection and quantification in Positron Emission Tomography (opens in a new tab)

  12. Improved Quantification for Respiratory Gated PET/CT: Data-Driven Algorithms for Respiratory Motion Correction in PET/CT

    Respiratory motion is a significant general problem in Positron Emission Tomography (PET) imaging, affecting both image quality and quantitative accuracy. Respiratory motion not only blurs lesions and other anatomical features in the lungs, but also complicates the application of attenuation …

    ucl Repository record for Improved Quantification for Respiratory Gated PET/CT: Data-Driven Algorithms for Respiratory Motion Correction in PET/CT (opens in a new tab)

  13. Development and optimization of methods for quantitative Magnetic Resonance Imaging: QSM and DCE-MR

    … were tested. (ii) implementation of a non-rigid respiratory motion correction (MC) framework for dynamic contrast enhanced MR (DCE-MR) imaging of the liver. DCE-MRI data was acquired at 3T during free breathing for 5 min, using a 3D T1-weighted Golden Angle Radial Phase Encoding (GRPE) sequence. …

    fu-berlin Repository record for Development and optimization of methods for quantitative Magnetic Resonance Imaging: QSM and DCE-MR (opens in a new tab)

  14. Accelerating Multi‐Dimensional Magnetic Resonance Imaging of Blood Flow and Turbulence in the Cardiovascular System

    … of blood velocity vector fields. To address respiratory motion artifacts, retrospective non‐rigid respiratory motion correction incorporated into an iterative parallel imaging reconstruction algorithm is proposed. Furthermore, optimized k‐t sampling patterns are derived for combined parallel …

    kings Repository record for Accelerating Multi‐Dimensional Magnetic Resonance Imaging of Blood Flow and Turbulence in the Cardiovascular System (opens in a new tab)

  15. A Simultaneous Multicontrast PET-MR Sequence for Comprehensive Cardiac MRI

    … and cardiac sarcoidosis. However, respiratory motion and misregistration between free-breathing 3D PET and 2D breath-held MR images are key challenges that have hindered their clinical translation. This thesis introduces a cutting-edge framework for simultaneous motion-compensated …

    kings Repository record for A Simultaneous Multicontrast PET-MR Sequence for Comprehensive Cardiac MRI (opens in a new tab)

  16. Design of Pulse Sequences for Low-Field Cardiac MRI Using Bloch Simulations

    … navigators (iNAVs) were employed for non-rigid respiratory motion correction to enable 100% respiratory scan efficiency, while patch-based denoising techniques were used to mitigate the reduced signal-to-noise ratio at 0.55T and accelerate the scans. As explained, for both sequences, the …

    kings Repository record for Design of Pulse Sequences for Low-Field Cardiac MRI Using Bloch Simulations (opens in a new tab)

  17. Motion-Corrected Simultaneous Cardiac PET-MR Imaging

    … examination. However, image degradation due to respiratory and cardiac motion during data acquisition remains a major challenge that has hindered the adoption of PET-MR in the clinical setting. State-of-the-art PET-MR technical developments have focused on using MR information for improving PET …

    kings Repository record for Motion-Corrected Simultaneous Cardiac PET-MR Imaging (opens in a new tab)

  18. Qualitative and Quantitative Improvements for Positron Emission Tomography Using Different Motion Correction Methodologies

    … quantitative accuracy due to different kinds of motion of patients during imaging. Hardware-based motion correction is currently the standard; however, is limited by several constraints, the most important of which is retroactive data correction. Data-driven techniques to perform motion …

    utk-theses Repository record for Qualitative and Quantitative Improvements for Positron Emission Tomography Using Different Motion Correction Methodologies (opens in a new tab)

  19. Advanced Motion Corrected Reconstruction Techniques for Magnetic Resonance Imaging

    … Sensing reconstructions. <br/><br/>Patient motion is one of the major obstacles in clinical MRI, as physiological motion is typically faster than the acquisition process. Motion occurring during a scan will corrupt the acquired data and introduce image artefacts in the reconstructed image. …

    kings Repository record for Advanced Motion Corrected Reconstruction Techniques for Magnetic Resonance Imaging (opens in a new tab)

Page 1 of 2