Showing 1 to 20 of 416 for “"Respiratory rate"”.
-
Microcomputer-controlled respiratory rate monitor
… Indirect Calorimetry, which measures metabolic rate by sampling the inlet and outlet concentrations of respiratory gases (oxygen and carbon dioxide) of the chamber. The system is controlled by an IBM PC which will control six chambers or twelve chambers simultaneously.</p><p>The system assesses …
-
Measuring Respiratory Rate in Children
Respiratory rate is an important vital sign used in the initial and ongoing assessment of all children in hospital. It is also used as a predictor of serious deterioration in a patient's clinical condition. Measuring respiratory rate in children can be difficult to perform and time consuming, …
-
The respiratory rate and volume of the guinea pig
The present methods for the measurement of respiratory rate and volume of laboratory animals have been reviewed. The review suggests that these methods leave much to be desired. For this reason an apparatus has been developed in the hope that it may overcome the difficulties associated with those …
-
Neonatal Respiratory Rate Monitoring Using a Pressure-Sensitive Mat
… patient vital signs such as respiration rate (RR) and heart rate (HR). Non-contact patient monitoring in Neonatal Intensive Care Units (NICU) can improve the quality of patient care and reduce patient discomfort. A clinical trial was conducted with the Children's Hospital of Eastern …
-
Contactless extraction of respiratory rate from depth and thermal sensors
… deficits. The current methods of estimating the respiratory rate such as Pneumograph, Capnograph, Photo-plethysmograph (PPG), Respiratory inductance plethysmography (RIP), involve sensors that are in contact with the patient. However, we have a few scenarios such as in hospitals and senior …
-
Derivation of the respiratory rate signal from a single lead ECG
… that respiration has an influence on heart rate, and this effect is called respiratory sinus arrhythmia. As a result, two inferences can be postulated: first respiration information can be derived from cardiac activity, and second this effect offers the potential of removing the respiration …
-
Continuous respiratory rate monitoring to detect clinical deteriorations using wearable sensors
… sensors for continuous physiological monitoring. Respiratory rate (RR) is not commonly monitored by wearable sensors, despite being a sensitive marker of deteriorations. This thesis presents investigations to identify an algorithm suitable for estimating RR from two signals commonly acquired by …
-
An investigation into what influences nurses' practice to not take and record respiratory rate
… Nurses (RNs) to not take and record patients’ respiratory rate. It was an exploratory descriptive qualitative study based on semi-structured telephone interviews with ten RNs working in three hospitals within New Zealand. The interviews aimed to investigate their experiences around the practice …
-
A Machine Learning-Based Non-Contact Respiratory Rate Monitoring Method Using an RGB Camera
Non-contact measurement of Respiratory Rate (RR) is suitable for various clinical and home-based healthcare applications. RR monitoring can inform healthcare providers of early indicators of critical illnesses. However, the obtrusive nature of contact-based sensors for RR monitoring makes them …
-
The effect of music on blood pressure, heart rate, and respiratory rate in premature infants
… consisting of systolic blood pressure, heart rate, and respiratory rate, were observed and measured for increases or decreases outside the resting range of each individual infant.</p> <p>Ten premature infants between 33 and 35 weeks post conceptual age who were receiving oral feedings were …
-
Developing a video expert panel as a reference standard to evaluate respiratory rate counting in paediatric pneumonia diagnosis
… to the World Health Organization (WHO) Integrated Management of Childhood Illness (IMCI) guidelines, the diagnosis of pneumonia is primarily based on fast breathing and chest indrawing. Non-physician health workers play a crucial role in identifying and treating pneumonia in LMICs. …
-
Effects of Elevated Ambient Temperature on Respiratory Rate, Body Temperature and Energy-Expenditure Rate of Sows and Gilts Around Parturition
Made available in DSpace on 2014-12-13T19:42:40Z (GMT). No. of bitstreams: 1 7624113.pdf: 4010641 bytes, checksum: 71ae03f1ddb9112bc4cbf259384ee085 (MD5) Previous issue date: 1976
-
The effect of frost defoliation upon the respiratory rate of the sugar beet root and the oxidases present in the beet root.
The effect of frost defoliation upon the respiratory rate of the sugar beet root has been determined. The leaves of 140 mature sugar beets were frozen until brittle and the petioles were frozen to within two inches of the crown on August 18, 1957. Twenty-five beet samples were taken one, four, …
-
The effect of rapid rib raising technique on heart rate, respiratory rate, pain pressure threshold and systolic and diastolic blood pressure in asymptomatic participants
… output included blood pressure, heart rate, respiratory rate and pain pressure threshold and were recorded at the end of each rest and intervention period. There was a significant increase in respiration rate after rapid articulation when compared to placebo and control groups. No other …
-
One breath at a time : a feasibility study
… face challenges such as estimating incorrect respiratory rate values in low-light conditions, the inability to detect shallow breathing, overestimating respiratory values in darker skin tones and the need for contact sensors that may disturb sensitive infants. In this study, we propose a novel …
-
Μελέτη παρατήρησης της συχνότητας εμφάνισης ταχύπνοιας μη εξαρτώμενης από το αναπνευστικό φορτίο, σε βαρέως πάσχοντες ασθενείς κατά την περίοδο απογαλακτισμού τους από τον αναπνευστήρα
General part. Respiratory rate can be considered as a final output of o complex system. This complex system is composed from a central controller, the effectors and the sensors. The central controller (central nervous system) receives information through sensors from the periphery and then through …
-
A Millimeter-Wave Radar and Kinect Depth Camera for Non-Contact Respiratory Sensing
Remote, non-contact respiratory sensing has gained interest in the past decade with the dawn of cheaper microwave integrated circuits and optical devices. The need for an inexpensive and portable respiratory monitor is in particular demand in a hospital setting as the respiratory rate provides …
-
Smart E-Textiles Integrated into Human Health Monitoring Systems
… is at the forefront of concern. To illustrate the potential of e-textile monitoring in health care, two applications of health monitoring were chosen: monitoring respiratory rate and monitoring the dyadic interactions between a parent and their infant, specifically kangaroo care. As one of …