Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 26 for “"Respiratory-Gated"”

  1. Respiratory-Gated IMRT Quality Assurance with Motion in Two Dimensions

    … patient with the use of a four-dimensional (4D) respiratorygatedcomputed tomography (CT), with time being the fourth dimension. The 4Drespiratory-gated CT allows for the internal margin (IM), the expansion of thetumor volume that accounts for physiologic motions, to be addressed in thetreatment …

    ohiolink Repository record for Respiratory-Gated IMRT Quality Assurance with Motion in Two Dimensions (opens in a new tab)

  2. Respiratory-gated liver stereotactic radiotherapy in flattening filter free photon mode

    Respiratory motion makes radiotherapy of abdominal targets, such as the liver difficult. Respiratory gating is used to treat tumours in select portions of the respiratory cycle where their location is well known, increasing target coverage precision and reducing normal tissue damage. The tradeoff …

    ubc Repository record for Respiratory-gated liver stereotactic radiotherapy in flattening filter free photon mode (opens in a new tab)

  3. Improved Quantification for Respiratory Gated PET/CT: Data-Driven Algorithms for Respiratory Motion Correction in PET/CT

    Respiratory motion is a significant general problem in Positron Emission Tomography (PET) imaging, affecting both image quality and quantitative accuracy. Respiratory motion not only blurs lesions and other anatomical features in the lungs, but also complicates the application of attenuation …

    ucl Repository record for Improved Quantification for Respiratory Gated PET/CT: Data-Driven Algorithms for Respiratory Motion Correction in PET/CT (opens in a new tab)

  4. Comparison of sedated respiratory-gated computed tomography (CT) to anesthetized inspiratory : expiratory breath-hold CT in dogs

    [EMBARGOED UNTIL 08/01/2026] Dogs experiencing respiratory compromise typically have multiple respiratory disorders that can be underestimated or overlooked by thoracic radiography. The anesthetized, ventilator-assisted inspiratory: expiratory breath-hold (I:E BH) CT technique provides …

    missouri Repository record for Comparison of sedated respiratory-gated computed tomography (CT) to anesthetized inspiratory : expiratory breath-hold CT in dogs (opens in a new tab)

  5. Verification of The Clinical Implementation of The Respiratory Gated Beam Delivery Technique With Synchrotron-Based Proton Irradiation

    … motion. One way to reduce uncertainty caused by respiratory motion is to use gated beam delivery. The main goal of this dissertation is to evaluate the respiratory gating technique in both passive scattering and scanning delivery mode. Our hypothesis for the study was that optimization of the …

    uthsc Repository record for Verification of The Clinical Implementation of The Respiratory Gated Beam Delivery Technique With Synchrotron-Based Proton Irradiation (opens in a new tab)

  6. Dosimetric Verification of Respiratory-Gated Radiation Therapy using a Dynamic Phantom for Commissioning the Varian Real-Time Position Management System

    … thoracic and abdominal cavities are subject to respiratory motion which can cause the undesired effect of moving the target out of the radiation field. A possible result from this type of motion is under-dosing the target and over-dosing the surrounding normal tissue. Respiratory-Gated …

    ohiolink Repository record for Dosimetric Verification of Respiratory-Gated Radiation Therapy using a Dynamic Phantom for Commissioning the Varian Real-Time Position Management System (opens in a new tab)

  7. 3-D lung deformation and function from respiratory-gated 4-D x-ray CT images : application to radiation treatment planning.

    … they have advanced significantly and have aggregated. In the realm of external beam radiation therapy of patients suffering from lung cancer, determination of patterns of pre- and post-treatment motion, and measures of regional and global lung elasticity and function are clinically relevant. In …

    louisville Repository record for 3-D lung deformation and function from respiratory-gated 4-D x-ray CT images : application to radiation treatment planning. (opens in a new tab)

  8. Using in vivo respiratory-gated micro-computed tomography imaging to monitor pulmonary side effects in 10 MV FLASH and conventional radiotherapy

    … pulmonary complications with in vivo respiratory-gated micro-CT imaging methods in free-breathing mice. Thirty C57BL/6 mice were selected for this research project. Baseline respiratory-gated micro-CT images of individuals were collected a week before receiving treatments. During each …

    ubc Repository record for Using in vivo respiratory-gated micro-computed tomography imaging to monitor pulmonary side effects in 10 MV FLASH and conventional radiotherapy (opens in a new tab)

  9. Application of Three-Dimensional Motion Tracking of Low-Activity Fiducial Positron-Emitting Markers in Radiation Therapy and Positron Emission Tomography

    … (PET) images. Those adverse effects can be mitigated by tracking the patient body motion and using the information appropriately. A technique that can track the three-dimensional motion of low-activity positron-emitting fiducial markers was developed. The application of this tracking technique, …

    carleton Repository record for Application of Three-Dimensional Motion Tracking of Low-Activity Fiducial Positron-Emitting Markers in Radiation Therapy and Positron Emission Tomography (opens in a new tab)

  10. Implementation of a video based respiratory gating system for radiation therapy

    … the dose to healthy lung tissue. In this work, a respiratory gated radiation therapy program is established at the Thompson Cancer Survival Center for the treatment lung cancer. A commercially available gating system is used to selectively deliver absorbed dose to moving target volumes during time …

    utk-theses Repository record for Implementation of a video based respiratory gating system for radiation therapy (opens in a new tab)

  11. Reduction of CT dose for CT-based PET attenuation correction

    … for quantitative PET/CT imaging come from respiratory motion in lung cancer imaging and estimation of the attenuation coefficients for high atomic number materials in bone imaging. Longer duration respiratory-gated CT has been proposed for attenuation correction of phase-matched …

    washington Repository record for Reduction of CT dose for CT-based PET attenuation correction (opens in a new tab)

  12. Management of Respiratory Motion in Radiation Oncology

    Respiratory motion poses significant problems in the radiotherapy of tumors located at sites (lung, liver, pancreas, breast) that are affected by such motion. Effects of respiratory motion on the different stages of the radiotherapy process (imaging, treatment planning and treatment delivery), has …

    vcu Repository record for Management of Respiratory Motion in Radiation Oncology (opens in a new tab)

  13. Increasing 18F-FDG PET/CT Capabilities in Radiotherapy for Lung and Esophageal Cancer via Image Feature Analysis

    … the features differed between conventional and respiratory-gated PET/CT images in lung cancer was analyzed. The influence of noise on image features was analyzed by applying uncorrelated, Gaussian noise to PET/CT images and measuring how significantly noise affected features. Quantitative PET/CT …

    usf Repository record for Increasing 18F-FDG PET/CT Capabilities in Radiotherapy for Lung and Esophageal Cancer via Image Feature Analysis (opens in a new tab)

  14. Frequency-selective Methods for Hyperpolarized 13C Cardiac Magnetic Resonance Imaging

    … it challenging to acquire full cardiac and respiratory-gated, whole-heart metabolic volumes. Each of the developments described in this thesis is intended to advance cardiac hyperpolarized 13C metabolic imaging towards a routine, clinical exam which can be used for prognosis and treatment …

    toronto-retro Repository record for Frequency-selective Methods for Hyperpolarized 13C Cardiac Magnetic Resonance Imaging (opens in a new tab)

  15. Avaliação do movimento respiratório em radioterapia utilizando simulação Monte Carlo

    The aim of the study was to evaluate respiratory motion, which is one of the major sources of error in all radiotherapy techniques but is particularly critical in techniques such as the corporal stereotactic radiotherapy, which applies high doses in a few fractions. The Monte Carlo method is today …

    brazil-uerj Repository record for Avaliação do movimento respiratório em radioterapia utilizando simulação Monte Carlo (opens in a new tab)

  16. AI Tools for Respiratory Motion Estimation in Cardiac SPECT with a Dedicated Multipinhole Camera

    … long that motion over the course of a patient’s respiratory cycle can result in image degradation. This work presents and develops an artificial-intelligence (AI) approach to motion estimation for respiratory gated cardiac SPECT projection data using a dedicated cardiac scanner. An initial …

    carleton Repository record for AI Tools for Respiratory Motion Estimation in Cardiac SPECT with a Dedicated Multipinhole Camera (opens in a new tab)

  17. Respiratory motion correction in PET/CT imaging

    In dual modality PET-CT imaging, respiratory motion can introduce blurring in PET images and create a spatial mismatch between the PET and CT datasets. Attenuation correction errors can result from this mismatch, which can produce severe artefacts that potentially alter the clinical interpretation …

    kings Repository record for Respiratory motion correction in PET/CT imaging (opens in a new tab)

  18. Ultra-low-dose CT-based attenuation correction for respiratory motion compensation in PET/CT imaging

    … (CT) attenuation correction (CTAC) due to respiratory motion is a known source of errors in PET imaging. In theory, this can be corrected by matching individual PET and CT phases which have been generated by respiratory-correlated PET and CT. However, due to the high variability of patient …

    washington Repository record for Ultra-low-dose CT-based attenuation correction for respiratory motion compensation in PET/CT imaging (opens in a new tab)

  19. Relation of regional tidal lung expansion with inflammatory activation in early ventilator-induced lung injury: a pet imaging approach

    … is a life-saving intervention in patients with respiratory failure, but can exacerbate lung injury or produce inflammation in healthy lungs, side effects termed ventilator-induced lung injury (VILI). One putative mechanism of VILI is the triggering of inflammation through cyclic stretching of …

    bu Repository record for Relation of regional tidal lung expansion with inflammatory activation in early ventilator-induced lung injury: a pet imaging approach (opens in a new tab)

Page 1 of 2