Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 93 for “"Retinal nerve fiber layer"”.

  1. Retinal Nerve Fiber Layer Composition and Ganglion Cell Estimation in Experimental Glaucoma

    … non-axonal content within the circumpapillary retinal nerve fiber layer (RNFL), and develop a histologically informed model for estimating ganglion cell axon content from RNFL thickness profiles in a non-human primate model of experimental glaucoma. Methods: In Aim 1, the distribution of …

    houston Repository record for Retinal Nerve Fiber Layer Composition and Ganglion Cell Estimation in Experimental Glaucoma (opens in a new tab) Embargoed until 2028-08-01

  2. Methodologies for Analyzing Retinal Nerve Fiber Layer Thickness/Area Using Spectral Domain Optical Coherence Tomography.

    … of the disease. The most common quantifiable retinal structure is the peripapillary retinal nerve fiber layer (RNFL), a surrogate for the total ganglion cell content within the eye. With technologies such as spectral domain optical coherence tomography (SD OCT), the RNFL thickness can be …

    houston Repository record for Methodologies for Analyzing Retinal Nerve Fiber Layer Thickness/Area Using Spectral Domain Optical Coherence Tomography. (opens in a new tab)

  3. Thickness, phase retardation, birefringence, and reflectance of the retinal nerve fiber layer : implications for glaucoma diagnosis

    … cause of blindness worldwide after cataract. Retinal nerve fiber layer thickness (RNFLT), phase retardation, and birefringence measured by Polarization Sensitive Optical Coherence Tomography (PS-OCT) have been used for glaucoma diagnosis. We first investigated two different image registration …

    texas Repository record for Thickness, phase retardation, birefringence, and reflectance of the retinal nerve fiber layer : implications for glaucoma diagnosis (opens in a new tab)

  4. Relationship Between Corneal Biomechanics In Sjögren’S Disease And Risk Factors For Glaucoma Development

    … These properties will then be correlated with retinal nerve fiber layer and ganglion cell layer thickness. Evaluating these findings will provide more information on whether there is a correlation between risk factors of glaucoma, represented by retinal nerve fiber layer thickness, and weakened …

    uab Repository record for Relationship Between Corneal Biomechanics In Sjögren’S Disease And Risk Factors For Glaucoma Development (opens in a new tab)

  5. Swept Source Polarization Sensitive Optical Coherence Tomography for retinal imaging at 1 micron

    … is characterized by irreversible damage to retinal ganglion cells. Once glaucoma is detected, further vision loss can be prevented by pharmacological or surgical treatment. However, current diagnostic methods lack the necessary sensitivity and up to 40% of vision maybe irreversibly lost …

    texas Repository record for Swept Source Polarization Sensitive Optical Coherence Tomography for retinal imaging at 1 micron (opens in a new tab)

  6. Μελέτη των δομικών αλλοιώσεων του αμφιβληστροειδή στα διάφορα στάδια της νόσου Αlzheimer

    … optic nipple. Efforts are being made to identify retinal biomarkers capable of making optical coherence tomography a reliable adjunctive screening method in the early diagnosis of patients with Mild Cognitive Impairment (MCI). This is very important considering that patients with MCI develop …

    greece Repository record for Μελέτη των δομικών αλλοιώσεων του αμφιβληστροειδή στα διάφορα στάδια της νόσου Αlzheimer (opens in a new tab)

  7. Η συμβολή της περιμετρίας βραχέως μήκους κύματος (SWAP) και του αναλυτή των νευρικών ινών (SLP) στην μελέτη της οφθαλμικής υπερτονίας

    Aims: To compare and correlate retinal nerve fiber layer (RNFL) measurements obtained by Scanning Laser Polarimetry (SLP) with defects detected by short wavelength automatic perimetry (SWAP) in eyes with ocular hypertension (OHT). Methods: Scanning Laser polarimetry and SWAP was performed in …

    greece Repository record for Η συμβολή της περιμετρίας βραχέως μήκους κύματος (SWAP) και του αναλυτή των νευρικών ινών (SLP) στην μελέτη της οφθαλμικής υπερτονίας (opens in a new tab)

  8. Μελέτη του πάχους του χοριοειδούς χιτώνα σε ασθενείς με β-θαλασσαιμία

    … as well as central macular thickness and retinal nerve fiber layer thickness, were evaluated using optical coherence tomography imaging. Results: Thirty-eight TD-β-thal patients (mean age 42 ± 10.7 years) and 22 healthy controls (mean age 40.3 ± 10.2 years) were included in the study. …

    greece Repository record for Μελέτη του πάχους του χοριοειδούς χιτώνα σε ασθενείς με β-θαλασσαιμία (opens in a new tab)

  9. Application of polarization sensitive optical coherence tomography (PS-OCT) and phase sensitive optical coherence tomography (PhS-OCT) for retinal diagnostics

    … for high sensitivity cross-sectional imaging of Retinal Nerve Fiber Layer (RNFL) has been designed, constructed, and verified. The instrument is capable of measuring the thickness and birefringence of the RNFL. Birefringence change of the RNFL could serve as an early indicator of glaucoma. The …

    texas Repository record for Application of polarization sensitive optical coherence tomography (PS-OCT) and phase sensitive optical coherence tomography (PhS-OCT) for retinal diagnostics (opens in a new tab)

  10. Second Harmonic Generation – A Novel Approach in Retinal Imaging

    … label-free imaging of microtubules (MTs) in the retinal nerve fiber layer (RNFL). MTs are an important part of axonal cytoskeleton, providing structural support and serving as a railroad in intracellular transport. We demonstrate the application of SHG microscopy to the following studies: 1) Can …

    cuny-grad Repository record for Second Harmonic Generation – A Novel Approach in Retinal Imaging (opens in a new tab)

  11. Structure and Function in Early Glaucoma

    … that cause a specific neuropathy of the optic nerve (Greenfield, Bagga, et al. 2003) of which abnormalities associated with this disorder are localized at the level of the retinal ganglion cell layer (Epstein 1997; Quigley & Broman 2006). This structure-function relationship is not clear as it …

    waterloo Repository record for Structure and Function in Early Glaucoma (opens in a new tab)

  12. DEEP LEARNING ALGORITHMS FOR OPTICAL COHERENCE TOMOGRAPHY IMAGES WITH APPLICATIONS IN GLAUCOMA

    … in complex 3D biomechanical changes of the optic nerve head tissues (ONH), is indeed a well-known risk factor and considered as the only clinically treatable one. Since the inception of optical coherence tomography (OCT) technology, it has been possible for the in vivo assessment of these …

    nus Repository record for DEEP LEARNING ALGORITHMS FOR OPTICAL COHERENCE TOMOGRAPHY IMAGES WITH APPLICATIONS IN GLAUCOMA (opens in a new tab) Download file for DEEP LEARNING ALGORITHMS FOR OPTICAL COHERENCE TOMOGRAPHY IMAGES WITH APPLICATIONS IN GLAUCOMA (opens in a new tab)

  13. Phase retardation measurement with capillary blood flow using polarization sensitive optical coherence tomography

    … birefringence of biological samples, namely the retinal nerve fiber layer (RNFL). The presence of blood vessels in biological samples complicates accurate measurement of tissue birefringence as a result of the Doppler shift in fringe frequency and the shadowing effect below blood vessels due to …

    texas Repository record for Phase retardation measurement with capillary blood flow using polarization sensitive optical coherence tomography (opens in a new tab) Restricted access

  14. OCT changes in patients with fibromyalgia: a meta-analysis

    … ινών του αμφιβληστροειδούς (peripapillary Retinal Nerve Fiber Layer, pRNFL) διαφέρει μεταξύ ενηλίκων ασθενών με ινομυαλγία και υγιών μαρτύρων, διερευνώντας παράλληλα τον δυνητικό ρόλο των παραμέτρων του αμφιβληστροειδούς που προκύπτουν από την OCT ως βιοδεικτών της νόσου.

    athens Repository record for OCT changes in patients with fibromyalgia: a meta-analysis (opens in a new tab)

  15. Optical designs and image processing algorithms for optical coherence tomography detection of glaucoma

    … of analyzing ophthalmologic OCT images, a retinal sublayer segmentation algorithm is presented and implemented with GPU assisted computation. Then, a polarization-sensitive optical coherence tomography (PS-OCT) system was constructed for the study of glaucoma. Three closely related clinical …

    texas Repository record for Optical designs and image processing algorithms for optical coherence tomography detection of glaucoma (opens in a new tab)

  16. Spectral Domain Optical Coherence Tomography System Development for in Vivo Ophthalmic Imaging

    … as a powerful new tool for noninvasive human retinal imaging. I have developed a low‐cost, high resolution real‐time Spectral Domain Optical Coherence Tomography (SDOCT) system optimized for rapid 3D imaging of the human retina in vivo. Then functional retinal OCT imaging such as polarization …

    duke Repository record for Spectral Domain Optical Coherence Tomography System Development for in Vivo Ophthalmic Imaging (opens in a new tab)

Page 1 of 5