Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 640 for “"Reverse Phase"”

  1. Models for the preprocessing of reverse phase protein arrays

    Reverse-phase protein lysate arrays (RPPA) are becoming important tools for the analysis of proteins in biological systems. RPPAs combine current assays for detecting and measuring proteins with the high-throughput technology of microarrays. Protein level assays have the ability to address …

    rice Repository record for Models for the preprocessing of reverse phase protein arrays (opens in a new tab)

  2. Relative Quantifizierung von Proteinen mittels Reverse Phase Protein Microarrays

    … Nachweismethoden, wie die Analyse mittels Reverse Phase Protein Microarrays, sind in der Lage Änderungen des Proteoms direkt nachweisen zu können. Ziel dieser Arbeit war die relative Quantifizierung von Proteinen mittels RPMAs anhand der Stimulierung des PKA Signaltransduktionsweges. Um …

    fu-berlin Repository record for Relative Quantifizierung von Proteinen mittels Reverse Phase Protein Microarrays (opens in a new tab)

  3. Analyse von Signalproteinen in Zelllinien und Tumorgewebe mit Reverse Phase Proteinarrays

    … Zur Beantwortung dieser Fragen wurde auf die Reverse Phase Proteinarray-Technologie zurückgegriffen, die zunächst im Hinblick auf Durchsatz, Sensitivität und Robustheit weiterentwickelt wurde. Eine antikörperbasierte Signalamplifikation wurde zur Steigerung der Sensitivität entwickelt, um auch …

    heid-diss Repository record for Analyse von Signalproteinen in Zelllinien und Tumorgewebe mit Reverse Phase Proteinarrays (opens in a new tab)

  4. Non-Destructive Determination of Surface Area in Reverse Phase Chromatographic Columns

    … Standard Excess Adsorption Isotherm (SEAI) for reverse phase C18 type columns. The methodology of the evaluation of the total amount of adsorbent in the column and the effective surface area of the C18 modified adsorbent is also discussed. These terms are critical for the successful evaluation …

    shu-thes Repository record for Non-Destructive Determination of Surface Area in Reverse Phase Chromatographic Columns (opens in a new tab)

  5. Polystyrene as a Medium in Reverse-Phase Separation Of Polycyclic Aromatic Hydrocarbons

    … two different kinds of polystyrene (PS) in the reversed phase. One was a zirconia-based column coated with polystyrene. The other was a polystyrene divinylbenzene (PS-DVB) column. The idea behind using these columns was to take advantage of extreme retention of PAHs by these columns by using …

    ohiolink Repository record for Polystyrene as a Medium in Reverse-Phase Separation Of Polycyclic Aromatic Hydrocarbons (opens in a new tab)

  6. The development and characterisation of a novel reverse-phase wet granulation process

    … to execute commercially. Consequently, a novel reverse-phase granulation process was developed and studied involving immersion of dry powder into the binder liquid, thus eliminating the traditional granule nucleation process. The reverse-phase process proceeds in the direction of reduced liquid …

    kings Repository record for The development and characterisation of a novel reverse-phase wet granulation process (opens in a new tab)

  7. Reduction of solvent effect in reverse phase gradient elution LC-ICP-MS

    <p>The groundwork for coupling gradient liquid chromatography (LC) with inductively coupled plasma mass spectrometry (ICP-MS) is developed. An alternative method of quantification to isotope dilution is evaluated. Using a micronebulizer (100 [Mu]L/min) and the Apex-Q desolvation system from …

    iastate Repository record for Reduction of solvent effect in reverse phase gradient elution LC-ICP-MS (opens in a new tab)

  8. The conformation study of a bioactive peptide by reverse-phase HPLC, CD and NMR

    … of this peptide, a conformation study by reverse-phase HPLC, CD, and NMR was carried out. Fromreverse-phase HPLC, two partly split peaks were observed at the beginning, which then combined to one peaks over time. From CD, there was no apparent difference in thepeptide solution over time. …

    ttu Repository record for The conformation study of a bioactive peptide by reverse-phase HPLC, CD and NMR (opens in a new tab)

  9. ANALYSES OF MULTIVITAMINS IN NUTRACEUTICALS BY REVERSE PHASE HPLC WITH DAD, ELSD AND MS

    … to minimize the consumption of solvents, solid phase extraction (SPE) has been introduced for sample preparation. In this study, two types of SPE, i.e., reversed-phase C18 and strong anion-exchange phase, were used for sample clean-up and pre-concentration. The average recoveries for vitamin B3, …

    clemson Repository record for ANALYSES OF MULTIVITAMINS IN NUTRACEUTICALS BY REVERSE PHASE HPLC WITH DAD, ELSD AND MS (opens in a new tab)

  10. The determination of transition metal ions in anaerobic adhesives by reverse phase high performance liquid chromatography

    By using reverse phase high performance liquid chromatography (HPLC) and chelating agents such as dithiocarbamates or 8-hydroxyquinoline it was possible to separate a range of metal ions which are of importance in the polymerisation chemistry of anaeorbic adhesives. These metal-chelate complexes …

    dcu Repository record for The determination of transition metal ions in anaerobic adhesives by reverse phase high performance liquid chromatography (opens in a new tab)

  11. Developing a diagnostic tool for acyl carrier proteins through trypsinolysis, reverse-phase chromatography and native chemical ligation

    Polyketide biosynthesis is a field that has had tremendous advances in the past 50 years. The understanding of the mechanisms is updated as investigations delve into domain interactions of these microbial natural products. Although numerous polyketides are known, similarities in the sequence of …

    texas Repository record for Developing a diagnostic tool for acyl carrier proteins through trypsinolysis, reverse-phase chromatography and native chemical ligation (opens in a new tab)

  12. Reverse-phase Ion-Pairing Ultra Performance Liquid Chromatography-Mass Spectrometry In Characterization And Fingerprinting Of Diverse Sulfated Glycosaminoglycan Mimetics

    Heparin is a highly sulfated glycosaminoglycan with potent anticoagulant, antimetastatic, and anti-inflammatory effects. Polymeric and polyanionic nature of heparin makes dosing and side effects a nightmare for healthcare professionals. Our laboratory has proposed appropriately designed, small, …

    vcu Repository record for Reverse-phase Ion-Pairing Ultra Performance Liquid Chromatography-Mass Spectrometry In Characterization And Fingerprinting Of Diverse Sulfated Glycosaminoglycan Mimetics (opens in a new tab)

  13. Development and Application of Ion Pair Reverse Phase HPLC for the Analysis of DNA Aptamers, dsRNA Biocontrols and mRNA Therapeutics

    … This study aimed to develop and utilise ion pair reverse phase HPLC (IP RP HPLC) to analyse and characterise mRNA therapeutics and dsRNA biocontrols. In addition, it was proposed that the SELEX procedure be optimised before generating ssDNA aptamers for the melanoma differentiation-associated …

    whiterose Repository record for Development and Application of Ion Pair Reverse Phase HPLC for the Analysis of DNA Aptamers, dsRNA Biocontrols and mRNA Therapeutics (opens in a new tab)

  14. Reverse phase high performance liquid chromatography with photodiode array detection method for the identification and detection of fat-soluble vitamins in plasma

    … vitamins in human blood samples using reverse-phase high performance liquid chromatography coupled with photodiode array detection. The biochemical forms of fat-soluble vitamins analyzed include retinol, cholecalciferol, calcidiol, α-tocopherol, γ-tocopherol, and phylloquinone. This …

    twu Repository record for Reverse phase high performance liquid chromatography with photodiode array detection method for the identification and detection of fat-soluble vitamins in plasma (opens in a new tab)

  15. Evaluating the effective peak capacity of a saw-tooth gradient for reverse-phase high performance liquid chromatography separation of proteins and peptides

    … and a low molecular weight human serum by reverse-phase high performance liquid chromatography. The peak splitting and number of peptides detected is used to characterize the effective peak capacity of the saw-tooth gradient as a function of solvent strength change (Delta&phis;). Peak …

    wvu Repository record for Evaluating the effective peak capacity of a saw-tooth gradient for reverse-phase high performance liquid chromatography separation of proteins and peptides (opens in a new tab)

Page 1 of 32