Stability of the Miniscrew-Bone Interface: Reverse Torque Values in Rabbits
… The purpose of this animal study was to measure reverse torque values for Absoanchor 1.2 mm and Micerium 1.5mm miniscrews at 0, 2, and 12 weeks under loaded and unloaded conditions. Methods: Ninety-six miniscrews were placed in the femora of twelve rabbits and allowed to heal for either two or …
-
Evaluating the Effect of the Protector Cap Technique for Castable Implant Abutments on Reverse Torque Values
… to masticatory forces and insufficient preload torque. Purpose: The purpose of this study is to evaluate the differences in reverse torque value between UCLA abutments with no casting performed, UCLA abutments cast using a conventional manner, and UCLA abutment cast using protection caps and …
-
In Vitro Study to Analyze Reverse Torque Values of Prosthetic Screws with Multiple Loosening/Tightening Preload Cycles
… can withstand before fracture, and to record the reverse torque values on each of the 10 applications of screw tightening and loosening. Materials and methods: The testing assemblies consisted of 30 temporary cylinder/multiunit abutment/internal connection implants, 10 each from Biohorizons, …
-
The effect of screw torque maintenance and re-applying screw torque on the retention of prosthetic screw for multi-unit implant restorations
… screw tightening protocols in terms of reverse torque values (RTV). Additionally, the effect of torquing and retorquing the same screw on RTV is also investigated. Methods: Nine implants (Nobel Replace Select, Nobel Biocare) with straight multiunit abutments and overlying temporary …
-
The effects of screw torque maintenance and re-applying screw torque on the retention of implant abutment screws in single implant restorations
… screw tightening protocol modification through torque maintenance or abutment screw retightening on an internal Tri-lobe connection implant influences abutment screw reverse torque values (RTV). To also investigate if torquing and retorquing the same implant screw has an influence on the RTV of …
-
Surgical implant and tissue interface
… such as pullout, four-point bending as well as reverse torque test. Implants were evaluated under ex vivo conditions, immediately after being placed within tissue as well as under in vivo conditions, 2- and 6-months following the implantation surgery in goat and equine animal model. Several …
-
Implant Overdenture Abutment Loosening under Hyperbaric Conditions
… into resin blocks. LOCATOR® abutments were torqued to 30 N-cm with a digital torque meter. The implants were divided into three different hyperbaric pressure groups: the control (1 atm), 2.8 atm, and 4 atm. Each pressure group was subdivided into two groups: a one cycle (one scuba dive) …