Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 78 for “"Rf coil"”.
-
Rf coil design for multi-frequency magnetic resonance imaging & spectroscopy
… magnetic resonance (NMR) transmitter/receivers (coils) capable of operating at multiple frequencies, while maintaining a good performance at each frequency. The objective of this work is to discuss various design approaches used for second-nuclei RF (radio frequency) coils, and to analyze the …
-
New RF coil arrays for Static and Dynamic Musculoskeletal Magnetic Resonance Imaging
… MSK imaging from the hardware perspective, with coil solutions for dynamic imaging of knee and high field imaging of hand. Starting with a brief introduction to MR physics, different types of RF coils are introduced in chapter 1, followed by sections on design of birdcage coils, phased arrays and …
-
Advancing RF coil technology for human brain magnetic resonance imaging at ultrahigh field
… due to wave behavior at UHF. Various RF engineering approaches have been used to improve MR imaging quality by enhancing the RF coil magnetic fields (B1) and imaging SNR. High permittivity material (HPM) technology provides an effective method to enhance the RF transmission (B1+) and …
-
RF Coil Design, Imaging Methods and Measurement of Ventilation with 19F C3F8 MRI
… by the following approaches: (i) Exploration of coil designs capable of imaging both proton (1H – 63.8 MHz at 1.5T) and fluorine (19F – 60.1 MHz at 1.5T) nuclei involved: 1. The novel use of microelectromechanical systems to switch a single transceive vest coil between the two nuclei was compared …
-
Magnetic Resonance RF Coil Modeling and Simulation: Analysis of Biot-Savart Law and Frequency Response Methods
… medical imaging often utilize radiofrequency (RF) coils for signal excitation and acquisition. The use of RF coils in magnetic resonance imaging provides a method to place a near-field antenna in close proximity with the anatomy of imaging interest and enables substantial improvements in the …
-
High-Resolution MRI for 3D Biomechanical Modeling: Signal Optimization Through RF Coil Design and MR Relaxometry
… time and improving SNR and CNR: the design of RF coils optimized to detect MRI signals from the anatomy of interest, and the determination of MRI relaxation properties of the tissues being imaged (allowing optimization of imaging parameters to improve CNR between tissues). Work on the larynx …
-
Development of High Impedance Microstrip Resonators and Design of Mitten RF coil Arrays for Ultrahigh Field MR Imaging
… resonator has been used as the radio frequency (RF) transceiver for magnetic resonance signal excitation and reception. Its application in parallel imaging could achieve faster imaging speed and better image quality. Mutual coupling is one of the major challenges in designing multichannel RF …
-
Determination Of Correlations Induced By The Sense And Grappa Pmri Models With An Application To Mri Rf Coil Design
… a new cost function for optimizing the design of RF coil arrays has also been developed and implemented to generate more favorable magnetic fields for functional connectivity studies in specific brain regions. Images reconstructed with such arrays have an improved signal-to-noise ratio and a …
-
Numerical and Experimental Assessment of MRI RF Coil Induced Heating for External Fixation Devices and Technique to Reduce the Thermal Effects
… devices. This dissertation focuses on the MRI RF coil induced heating effects of external fixation devices and the technique to reduce such thermal impact. Different categories of external fixation devices, including modular external fixation devices and circular external fixation devices are …
-
A 24-channel radio frequency receive array for magnetic resonance imaging of primates at 10.5 T
… other imaging technologies. The radio frequency (RF) coil is one of the key hardware sub-systems, which drives overall MRI system performance to enable higher resolution imaging and the collection of high fidelity information about organism structure and function. To optimize RF coil performance, …
-
RF and electronic design perspective on ultra-high field MRI systems
… challenges: the fully automatic matched / tuned RF head coil design and RF coil design with improved B1 field uniformity. Both have been being considered as critical problems at ultra-high field (7T and beyond) MRI systems. The first study aims to build a real-time, high-speed, electrically …
-
Parallel Transmission MRI for Optimised Cardiac Imaging and Improved Safety
… increased inhomogeneity in the radio frequency (RF) fields required to create MR signals and greater RF energy deposition – known as the specific absorption rate (SAR) – within imaging subjects. These factors have prompted the use of parallel transmission (PTx) MRI; in which multiple independent …
-
Massively Parallel Method of Moments for Fast and Reliable Electromagnetic Simulations for Dielectric Bodies and Metals
… plasma plumes or dielectric-filled apertures, performance of communication antennas in the presence of dielectric and magnetic inhomogeneities, and medical diagnostics and power absortion in biological bodies. Computational electromagnetics methods (CEM) offer and indispensable tool for …
-
Highly Parallel Magnetic Resonance Imaging with a Fourth Gradient Channel for Compensation of RF Phase Patterns
… was implemented to provide slice dependent RF coil phase compensation for arrays in dual-sided or "sandwich" configurations. The use of highly parallel arrays for single echo acquisition magnetic resonance imaging allows both highly accelerated imaging and capture of dynamic and single shot …
-
SAFETY AND PERFORMANCE CONSIDERATIONS FOR INTERACTIONS BETWEEN ELECTROMAGNETIC FIELDS AND BIOLOGICAL TISSUE: APPLICATIONS TO HIGH FIELD HUMAN MAGNETIC RESONANCE IMAGING AND TISSUE-IMPLANTED DEVICES
… comparable to the size of the load and/or the coil. The performance of the radiofrequency (RF) coil, as a result, becomes increasingly dependent on its electromagnetic interactions with the load, human body or head.
-
Investigation of Metamaterial Transmission line resonators for Ultra-High Field Magnetic Resonance Imaging RF Coils
The objective is to develop a highly efficient RF head coil on a thin substrate for the Ultra-high magnetic field (7 T and above) MRI systems. The artificial Metamaterial resonator is investigated for this purpose. Simulation and experimental results are provided for an 8-channel Metamaterial based …
-
Experimental and computational EM analysis of MRI RF coils and of their interaction with implanted conductive objects
Radio frequency (RF) coils are employed in Magnetic Resonance Imaging (MRI) to excite and detect the signal from nuclear spins at Larmor frequency. The intrinsic complexity of the phenomena involved inside an MR scanner leads to strong requirements on the magnetic field B1 generated by the RF coil …
-
Design and Numerical Investigation of RF Transceiver Arrays for 7T MR Imaging in Humans
… magnetic resonance devices employ phased array coils made of low impedance resonant loops. Electrodynamic interactions between elements in such arrays must be carefully balanced. To mitigate inductive coupling, neighboring coil components are strategically overlapped, and preamplifier interfaces …
Page 1 of 4