Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 165 for “"Ring down."”.

  1. Pulsed cavity ring-down spectroscopy in combustion environments

    … thesis gives an introduction to pulsed cavity ring-down absorption spectroscopy (CRDS) and its application in combustion research. Experimental results have been compared to numerical simulations, providing a means to validate reaction mechanisms and numerical approaches. Up to now, the …

    radboud Repository record for Pulsed cavity ring-down spectroscopy in combustion environments (opens in a new tab) Download PDF for Pulsed cavity ring-down spectroscopy in combustion environments (opens in a new tab)

  2. Fibre-Loop Ring-Down Spectroscopy Using Liquid Core Waveguides

    Cavity ring-down spectroscopy has been used over the last twenty years as a highly sensitive absorption spectroscopic technique to measure light attenuation in gases, liquids, and solid samples. An optical cavity is used as a multi-pass cell, and the decay time of the light intensity in the cavity …

    queens Repository record for Fibre-Loop Ring-Down Spectroscopy Using Liquid Core Waveguides (opens in a new tab)

  3. Pulsed ring-down antennas for implementation in a phased array

    … compactness for field application. The pulsed ring-down antenna has become of great interest due to its compact size and peak power on target potential. A pulsed ring-down antenna operates by charging the single element antenna with a high potential source and then closing a switch to develop …

    ttu Repository record for Pulsed ring-down antennas for implementation in a phased array (opens in a new tab)

  4. Probing Reactions in Monolayers Using Normal Incidence Cavity Ring-down Spectroscopy

    … of the polymer. Normal incidence cavity ring-down spectroscopy (NICRDS) was used to probe the monolayer system. Cavity ring-down spectroscopy (CRDS) is an ultra-sensitive absorption technique which has been extensively used for detection of gas-phase species and has recently been extended …

    unr Repository record for Probing Reactions in Monolayers Using Normal Incidence Cavity Ring-down Spectroscopy (opens in a new tab)

  5. Continuous Wave Ring-Down Spectroscopy for Velocity Distribution Measurements in Plasma

    Cavity Ring-Down Spectroscopy CRDS is a proven, ultra-sensitive, cavity enhanced absorption spectroscopy technique. When combined with a continuous wavelength (CW) diode laser that has a sufficiently narrow line width, the Doppler broadened absorption line, i.e., the velocity distribution functions …

    wvu Repository record for Continuous Wave Ring-Down Spectroscopy for Velocity Distribution Measurements in Plasma (opens in a new tab)

  6. Detection of Chemical Compounds Using Amplified Fiber Loop Ring-Down Spectroscopy

    Cavity ring-down spectroscopy (CRDS) is an absorption spectroscopic technique. In CRDS the concentration of an analyte is determined by measuring the reduction in finesse of an optical cavity made from two highly reflective (R>99.9%) mirrors once a sample is introduced. Optical loss is …

    queens Repository record for Detection of Chemical Compounds Using Amplified Fiber Loop Ring-Down Spectroscopy (opens in a new tab)

  7. Cavity ring-down spectroscopy instrumentation for airborne detection of nitrogen oxides

    Pulsed laser cavity ring-down spectroscopy (CaRDS) is a highly sensitive method for direct absorption spectroscopy that has been applied to in-situ detection of NO3, N2O5, NO2, NO, and O3, as well as NOx and NOy in the atmosphere from a variety of airborne platforms. CaRDS instruments have …

    cork Repository record for Cavity ring-down spectroscopy instrumentation for airborne detection of nitrogen oxides (opens in a new tab)

  8. Performance of a Mobile Solid State GPS Linked Pulsed Ring Down Array

    The development of mobile Pulsed Ring Down Source (PRDS) arrays requires theability to accurately determine the relative positions of array elements at distances, and in situations, where discrete measurements are not practical. At the frequencies of Iinterest, centimeter level accuracy is required …

    ttu Repository record for Performance of a Mobile Solid State GPS Linked Pulsed Ring Down Array (opens in a new tab)

  9. Performance of a mobile solid state GPS linked pulsed ring down array

    The development of mobile Pulsed Ring Down Source (PRDS) arrays requires the ability to accurately determine the relative positions of array elements at distances, and in situations, where discrete measurements are not practical. At the frequencies of interest, centimeter level accuracy is required …

    ttu Repository record for Performance of a mobile solid state GPS linked pulsed ring down array (opens in a new tab)

  10. Investigating reactive tropospheric nitrogen oxides by thermal-dissociation cavity ring-down spectroscopy

    … infrared (FTIR) and thermal dissociation cavity ring-down spectroscopy (TD CRDS). The interference from HONO in the measurement of NO2 by photolytic conversion with chemiluminescence detection (P-CL) was investigated in two prototype converters. The first used radiation centred around 395 nm, …

    calgary Repository record for Investigating reactive tropospheric nitrogen oxides by thermal-dissociation cavity ring-down spectroscopy (opens in a new tab)

  11. Barium sensing in hollow cathode plasma using cavity ring-down spectroscopy (CRDS)

    … using the laser diagnostic technique of cavity ring-down spectroscopy (CRDS) is presented. CRDS detects ground state neutral barium via absorption of the probe laser beam in the vicinity of 553.548 nm (air wavelength). The cathode CRDS measurements are performed along the axis of the cathode …

    colostate Repository record for Barium sensing in hollow cathode plasma using cavity ring-down spectroscopy (CRDS) (opens in a new tab)

  12. Indirect Detection of Explosive Vapours by Thermal Dissociation Cavity Ring-Down Spectroscopy

    … technique exploited radicals generated during the thermal decomposition of triacetone triperoxide (TATP), a peroxide explosive, for detection. These radicals were amplified via a peroxide radical chemical amplification scheme (PERCA) that required the addition of NO and a radical chain …

    calgary Repository record for Indirect Detection of Explosive Vapours by Thermal Dissociation Cavity Ring-Down Spectroscopy (opens in a new tab)

  13. Continuous-wave cavity ring down spectroscopy sensor for Hall thruster erosion measurement

    … its development in future applications requiring a long operational time (several thousands of hours). Sputter erosion of boron nitride (BN) acceleration channel wall is principal lifetime limitation for Hall thrusters. The sputtered particles can redeposit causing a critical contamination …

    colostate Repository record for Continuous-wave cavity ring down spectroscopy sensor for Hall thruster erosion measurement (opens in a new tab)

  14. Evaluation of a high-pressure, coaxial spark gap for pulsed ring-down applications

    … pressure, coaxial spark gap for use in pulse ring-down applications is presented. Additional comparisons with trigatron style triggering are also presented. The spark gap is triggered by field distortion of a center plane electrode. The switch was tested up to 75 pulses per second (pps) with a …

    ttu Repository record for Evaluation of a high-pressure, coaxial spark gap for pulsed ring-down applications (opens in a new tab)

  15. Ambient Measurements of the NOx Reservoir Species N2O5 using Cavity Ring-down Spectroscopy

    … the SHARP Field Study in Houston, TX in the spring of 2009. N2O5 measurements are compared to measurements of other species, including nitric acid and nitryl chloride, which were performed by other research groups. Mixing ratios exceeding 300 ppt were observed following ozone exceedance days, …

    tamu Repository record for Ambient Measurements of the NOx Reservoir Species N2O5 using Cavity Ring-down Spectroscopy (opens in a new tab)

  16. A New Diffuse Reflecting Material with Applications Including Integrating Cavity Ring-Down Spectroscopy

    … a new spectroscopic technique based on cavity ring-down spectroscopy using an integrating cavity made of our new diffuse reflector. This technique, which we call integrating cavity ring-down spectroscopy (ICRDS), has tremendous potential for sensitive absorption measurements of low-absorbing …

    tamu Repository record for A New Diffuse Reflecting Material with Applications Including Integrating Cavity Ring-Down Spectroscopy (opens in a new tab)

  17. Cavity ring down spectroscopy: a method to measure sputter erosion for EP applications

    … assessment. The present research develops cavity ring-down spectroscopy (CRDS) as a diagnostic tool to quantify sputter erosion. Measurements of sputtered particle number density and velocity are presented for a variety of target materials. The number density measurements are validated by …

    colostate Repository record for Cavity ring down spectroscopy: a method to measure sputter erosion for EP applications (opens in a new tab)

Page 1 of 9