Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 117 for “"Riveted"”

  1. The Efficiency of Riveted Structural Joints

    Made available in DSpace on 2014-12-05T17:36:43Z (GMT). No. of bitstreams: 1 0004478.pdf: 9248784 bytes, checksum: 34591906166a49a790afa4a7606640b2 (MD5) Previous issue date: 1952

    uiuc Repository record for The Efficiency of Riveted Structural Joints (opens in a new tab)

  2. FATIGUE BEHAVIOR AND SCALE EFFECTS IN RIVETED JOINTS

    Heavy duty riveted steel grating is commonly used in bridge construction as it is relatively lightweight and is readily installed. One particular design concern is fatigue, which may affect overall durability and service life of the deck. In this particular study, the fatigue behavior of the deck …

    ohiolink Repository record for FATIGUE BEHAVIOR AND SCALE EFFECTS IN RIVETED JOINTS (opens in a new tab)

  3. GRILLAGE ANALYSIS OF HEAVY-DUTY RIVETED STEEL GRATINGS

    A heavy-duty riveted steel grating is a lightweight and easy to install open grid bridge deck system used primarily in movable bridges. These systems may increase the load carrying capacity of the bridge deck because of the decrease in the dead weight of the structure. Initially, bridge decks were …

    ohiolink Repository record for GRILLAGE ANALYSIS OF HEAVY-DUTY RIVETED STEEL GRATINGS (opens in a new tab)

  4. TESTING AND ANALYSIS OF HEAVY DUTY RIVETED GRATINGS

    … the behavior and current design approach of riveted steel bar gratings due to improvements in design methodologies, as well as market pressure from new materials and forms of gratings. Development of finite element software has made the building and processing of models easy and efficient. …

    ohiolink Repository record for TESTING AND ANALYSIS OF HEAVY DUTY RIVETED GRATINGS (opens in a new tab)

  5. Behavior of Large Riveted and Bolted Structural Connections

    Made available in DSpace on 2014-12-05T17:37:03Z (GMT). No. of bitstreams: 1 5904500.pdf: 8168959 bytes, checksum: ffd82fa08ae92da59e64dc5a661ff5bd (MD5) Previous issue date: 1959

    uiuc Repository record for Behavior of Large Riveted and Bolted Structural Connections (opens in a new tab)

  6. Behavior of Riveted Connections in Steel Truss Bridges

    … loading limit is necessary. Past research on riveted connections has not included tests on as-built riveted connections, but rather shop fabricated specimens. Therefore, an enhanced understanding of ultimate rivet shear strength in gusset plates and the relation to connection length could …

    washington Repository record for Behavior of Riveted Connections in Steel Truss Bridges (opens in a new tab)

  7. Riveted Steel Railway Bridge Health Monitoring and Damage Detection

    Visual inspection is often used to assess the condition of railway bridges at discrete points in time, an approach that can be subjective and possibly unsafe. Alternatively, certain bridges have their condition assessed via the installation of a large number of sensors. These sensors can be costly …

    nebraska Repository record for Riveted Steel Railway Bridge Health Monitoring and Damage Detection (opens in a new tab)

  8. The design of a riveted plate girder railroad bridge

    Thesis (B.S.)--Michigan State College of Agriculture and Applied Science, 1949

    msu Repository record for The design of a riveted plate girder railroad bridge (opens in a new tab)

  9. Linear Finite Element Modeling of Joined Structures with Riveted Connections

    Riveted connections are widely used to join basic components, such as beams and panels, for engineering structures. However, accurately modeling joined structures with riveted connections can be a challenging task due to the riveting process of the connections. Solid rivets are ones of the most …

    ohiolink Repository record for Linear Finite Element Modeling of Joined Structures with Riveted Connections (opens in a new tab)

  10. Testing and Modeling of Nonlinearities in Riveted and Bolted Structures

    … 3, a similar approach is proposed for modeling riveted joints, which seeks to capture the vibrational response of a test structure including changes in the effective modal frequency and damping with vibration amplitude. A four parameter, nonlinear Iwan element is used to model each rivet joint …

    byu Repository record for Testing and Modeling of Nonlinearities in Riveted and Bolted Structures (opens in a new tab)

  11. Realistic fatigue assessment on historic riveted retrofitted railway bridges in Chile

    Fatigue damage is a major cause of failure in riveted railway bridges, particularly at stringer-to-floor-beam connections, which studies have identified as the most susceptible to fatigue. However, limited historical traffic data and structural details mean most assessments rely on the bridge's …

    ucl Repository record for Realistic fatigue assessment on historic riveted retrofitted railway bridges in Chile (opens in a new tab)

  12. Numerical simulations of riveted connections under quasi-static and dynamic loadings

    … is little known about the specific response of riveted connections under high rates of loading. A general lack of access and expertise with riveted connections, which have not been widely used in construction of bridges since the 1950s, and the expense and difficulty in replicating and …

    texas Repository record for Numerical simulations of riveted connections under quasi-static and dynamic loadings (opens in a new tab)

  13. On Fatigue Life Estimations of Riveted Details under Variable Amplitude Loading

    Old riveted railroad bridges currently in service in North America are being subjected to much higher live loads that they were originally designed for. Current fatigue provisions have been proven to provide robust estimations for riveted details. The purpose of this study is to determine how an …

    tamu Repository record for On Fatigue Life Estimations of Riveted Details under Variable Amplitude Loading (opens in a new tab)

  14. Seismic response of existing buildings constructed using semi-rigid riveted connections.

    The use of riveted semi-rigid connections was wide spread in building construction in the first half of the 20th century at a time when earthquake design was not required. It is therefore legitimate to question the seismic response of these historic buildings. Recent experimental work has shown …

    ottawa-retro Repository record for Seismic response of existing buildings constructed using semi-rigid riveted connections. (opens in a new tab)

  15. Experimental study on cyclic behaviour of riveted stiffened seat angle connections.

    Riveted Stiffened Seat Angle Connections have been used as beam-to-column joints in many old steel buildings. These connections are generally categorized as flexible. A concern exists as to the lateral resistance of frames built with these connections, particularly under earthquake excitations …

    ottawa-retro Repository record for Experimental study on cyclic behaviour of riveted stiffened seat angle connections. (opens in a new tab)

Page 1 of 6