Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 12 of 12 for “"Robotics--Calibration"”
-
ROBOT CALIBRATION USING STEREO VISION
… using the stereo vision technique in the robot calibration. Three cameras are used in measurement to extract the position information of a target point attached onto each of the robot manipulator links for the purpose of identifying the actual kinematic parameters of every link of the robot …
-
KALMAN FILTERING FOR ROBOTIC CALIBRATION
This thesis is concerned with the use of calibration techniques to increase robot accuracy. It is mainly an overview of some of the problems involved in the identification phase of calibration. A robot error model is developed and Kalman filtering algorithm is used in the identification of robot …
-
Workspace evaluation and kinematic calibration of Stewart platform
Parallel manipulators have their special characteristics in contrast to the traditional serial type of robots. Stewart platform is a typical six degree of freedom fully parallel robot manipulator. The goal of this research is to enhance the accuracy and the restricted workspace of the Stewart …
-
Self-calibration of laser tracking measurement system with planar constraints
… a fast sampling rate and high accuracy. Proper calibration of a laser tracking measurement system is essential prior to use of such a device for metrology. In the absence of a more accurate instrument for system calibration, one has to rely on self-calibration strategies. In this dissertation, a …
-
Integrated Active Ultrasound Systems for Medical Interventions
… ultrasound systems, (2) accurate and automatic calibration between ultrasound and other systems, and (3) improving the interventional tool imaging and tracking capability by combining ultrasound with optical systems. My main contribution to the first theme is inventing the active ultrasound …
-
Development of a graphical user interface for a Stewart platform
A user friendly graphical interface was developed to control a Stewart platform which is a six degree-of-freedom in-parallel mechanism. The interface allows the user to define the platform motion relative to various coordinate systems: base, platform and joint. The velocity/position reference to …
-
Simulated and Experimental Kinematic Calibration of a 4 Degrees of Freedom Parallel Manipulator
This thesis discusses the kinematic calibration of the constraining linkage of a four degrees of freedom parallel manipulator. The manipulator has hybrid actuation of joints and wires, however the wires are not considered in this calibration. Two of the passive joints of the manipulator contain …
-
Development and Implementation of a Self-Building Global Map for Autonomous Navigation
… are minimized. This work presents a method for calibration of mobile robot parameters using optimization. A cost function is developed based on the well-known UMBmark (University of Michigan Benchmark) test pattern. This method is presented as a simple time efficient calibration tool for use …
-
Probabilistic Calibration and Catheter Tracking with Robotic Systems
A significant boost in robotics technology has been observed in recent years and more and more tasks are being automated by robots such as robotic surgery, autonomous driving, package delivery, etc. Not only has the precision of robots been improved, but the number of robots involved in a specific …
-
Calibration of Ultra-high-precision Robots Operating in an Unsteady Environment
… thorough understanding of the physics behind nanorobotics. Specifically, to enable sub-micrometer accuracy for ultra-high-precision robots it is necessary to acquire a complete knowledge of how all sources of inaccuracy deform the robots at nano-scale. Furthermore, a way to compensate for such …