  1. CanalPro EAL Accuracy compared to the Root ZX EAL

    … Electronic Apex Locator Accuracy Compared to the Root ZX Electronic Apex locator Benjamin Brown, Garry Myers, Caroline Carrico, Duane Schaefer Department of Endodontics, Virginia Commonwealth University Objectives: Electronic apex locators (EAL) are an effective instrument in measuring the working …

    vcu Repository record for CanalPro EAL Accuracy compared to the Root ZX EAL (opens in a new tab)

  2. In Vitro Accuracy of the E-PEX Electronic Apex Locator Compared to the Root ZX II

    … One of the challenges of non-surgical root canal treatment (NSRCT) is determining the working length of the canal which indicates the exact end point of root canal preparation and obturation. The development of the Electronic Apex Locator (EAL) has helped the clinician to determine the …

    iupui Repository record for In Vitro Accuracy of the E-PEX Electronic Apex Locator Compared to the Root ZX II (opens in a new tab)

  3. Συγκριτική In Vitro Μελέτη της Αξιοπιστίας Τριών Ηλεκτρονικών Εντοπιστών Ακρορριζίου: S5 APEX LOCATOR, CANALPRO ΚΑΙ ROOT ZX II

    … τον υπολογισμό του μήκους εργασίας. Η συσκευή Root ZX II είναι η εξέλιξη της συσκευής Root ZX για την αξιοπιστία της οποίας υπάρχει εκτεταμένη αναφορά στην βιβλιογραφία και έχει αποτελέσει και η ίδια αντικείμενο πολλών μελετών. Για την συσκευή CanalPro υπάρχουν ελάχιστα βιβλιογραφικά δεδομένα …

    athens Repository record for Συγκριτική In Vitro Μελέτη της Αξιοπιστίας Τριών Ηλεκτρονικών Εντοπιστών Ακρορριζίου: S5 APEX LOCATOR, CANALPRO ΚΑΙ ROOT ZX II (opens in a new tab)

  4. In Vitro Precision of the E-PEX Electronic Apex Locator Compared to the Root ZX II in Various Embedding Media

    … One of the challenges of non-surgical root canal treatment (NSRCT) is determining the working length of the canal which indicates the end point of root canal preparation and obturation. The development of the Electronic Apex Locator (EAL) has helped the clinician to determine the …

    iupui Repository record for In Vitro Precision of the E-PEX Electronic Apex Locator Compared to the Root ZX II in Various Embedding Media (opens in a new tab)

  5. Evaluation eines neuen Modelles zur In-vitro Testung von Endometriegeräten

    … die Messgenauigkeit der beiden Endometriegeräte Root ZX und Raypex in-vitro evaluiert. <br>Ein spezieller Kunststoff wurde mit Ringer-Lösung getränkt; in diesem wurden an extrahierten Zähnen die Arbeitslängen der Zähne mit Hilfe von Headström-Feilen mit den Geräten Root ZX und Raypex bestimmt. …

    freiburg-diss Repository record for Evaluation eines neuen Modelles zur In-vitro Testung von Endometriegeräten (opens in a new tab)

  6. In Vitro Accuracy of the E-PEX Electronic Apex Locator Compared to the Root ZX II in the Presence of Various Irrigation Solutions

    … important aspects of a well-done non-surgical root canal treatment (NSRCT). This reference point determines the working length, and is commonly calculated with the aid of an electronic apex locator (EAL), which accurately identifies the apical foramen which in turn determines the working …

    iupui Repository record for In Vitro Accuracy of the E-PEX Electronic Apex Locator Compared to the Root ZX II in the Presence of Various Irrigation Solutions (opens in a new tab)

  7. AN IN VITRO EVALUATION OF THE WIRELE-X ELECTRONIC APEX LOCATOR

    … (EAL). The accuracy of the Wirele-X and the Root ZX II (J. Morita, Tokyo, Japan) was compared in vitro using an alginate model. Materials/Methods: Thirty-one extracted single-rooted human teeth with mature apices were decoronated at the CEJ. Under 10X magnification, actual canal lengths (ACL) …

    u-pacific Repository record for AN IN VITRO EVALUATION OF THE WIRELE-X ELECTRONIC APEX LOCATOR (opens in a new tab)

  8. Estudio in vitro de la fiabilidad mediante verificación histológica con microscopia óptica y electrónica de barrido de las conductometrías realizadas con el método radiográfico y electrónico

    … del paralelismo) y electrónicos (aparatos Root Zx y Justy II). Seleccionada la muestra de 90 dientes, esta fue dividida en 30 dientes para cada grupo. En el grupo I la técnica radiográfica fue realizada con la ayuda de un dispositivo especial con los dientes incluidos en bloques de …

    sevilla Repository record for Estudio in vitro de la fiabilidad mediante verificación histológica con microscopia óptica y electrónica de barrido de las conductometrías realizadas con el método radiográfico y electrónico (opens in a new tab)

  9. An In Vitro Evaluation of the Kontrolflex Accufile Hand File

    … to determine experimental canal lengths with the Root ZX II apex locator and size #10 Accufiles and Flexofiles. Differences between actual lengths and experimental lengths were compared with Student’s t test. The average experimental lengths were short of the actual length by -0.10 mm (±0.34) and …

    u-pacific Repository record for An In Vitro Evaluation of the Kontrolflex Accufile Hand File (opens in a new tab)

  10. The Effect of Insulating K-Type Files on Accuracy and Reliability as Used in Two Electronic Apex Locators

    … K files. Forty extracted human adult single-rooted teeth were coronally sectioned and placed in agar. EAL determined tooth length measurements were compared to actual tooth measurements. Comparisons to the standard measures used correlation and paired t-test. Preliminary comparisons of the …

    vcu Repository record for The Effect of Insulating K-Type Files on Accuracy and Reliability as Used in Two Electronic Apex Locators (opens in a new tab)

  11. Avaliação do método eletrônico na odontometria de molares decíduos: estudos in vivo e ex vivo

    … vivo e ex vivo, a precisão do localizador apical Root ZX (J. Morita Mfg. Corp.®, Tokyo, Japão) na determinação do comprimento de trabalho de molares decíduos e avaliar se a sua precisão é afetada pela presença de reabsorção radicular. Foram utilizados 15 molares decíduos totalizando 30 canais …

    brazil-ufsc Repository record for Avaliação do método eletrônico na odontometria de molares decíduos: estudos in vivo e ex vivo (opens in a new tab)

  12. Evaluation of Five Electronic Apex Locators Accuracy in Determining the Major Foramen and Apical Constriction: An in vitro study

    … electronic apex locators (EAL), including the Root ZX II, Endo-EZE FIND, APEX ID, ProMark, and Parkell Formatron. The evaluation of the EALs were two-fold. One objective was to evaluate the ability of each EAL to detect the major foramen, and the second objective was to evaluate the reliability …

    wvu Repository record for Evaluation of Five Electronic Apex Locators Accuracy in Determining the Major Foramen and Apical Constriction: An in vitro study (opens in a new tab)