Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 11 of 11 for “"S6-06"”
-
Evaluating Shear Capacity of Concrete Girders with Deficient Shear Reinforcement
… concrete members which do not comply with S6-06 Section 14 stirrup spacing and area requirements. The results of the evaluations indicate that the sectional shear provisions in S6-06, AASHTO LRFD-05 and software Response 2000 appropriately account for variations in stirrup spacing and area …
-
Second-order Analysis of Cable-stayed Bridge Deck Slabs
Current provisions in CSA S6-06 “Canadian Highway Bridge Design Code” for computing second-order effects in slender concrete beam-columns were derived for columns in buildings, where these effects can often be neglected, so their applicability to extremely slender cable-stayed bridge decks warrants …
-
Repair of GFRP Reinforced Concrete Bridge Barriers
… established and incorporated in current CAN/CSA-S6-06 code provisions. However, no test results are available on repairing GFRP-RC bridge barriers in case of damage caused by vehicle accidents. Therefore, this present research is aimed to conduct experiments on repairing full-scale GFRP-RC bridge …
-
Anchorage of stirrups in prestressed concrete I-girders
… in the Canadian Highway Bridge Design Code CSA S6-06. An experimental investigation was conducted on full-scale partial sections of a concrete I-girder to evaluate the performance of such non-code-compliant stirrup anchorages by comparing their performance to the performance of code-compliant …
-
Behaviour of Shear-critical Reinforced Concrete Beams Retrofitted with Externally Applied Fibre-reinforced Polymers
… over the current FRP design methods (CSA S6-06 and ACI 440.2R-08), which suggest a broadly applied maximum strain limit of 0.004 mm/mm, which was determined to be overly conservative for FRP rupture failures.
-
Long-term behaviour of GFRP prestressed concrete beams
… no design guidelines are provided by CAN/CSA-S806-12 or ACI 440.4R-04 for using prestressed GFRP bars in concrete members. This research study consisted of experimental and analytical phases, and was designed to assess the long-term properties of a concrete beams prestressed with a new …
-
The Effect of Surface and Loading Conditions on the Corrosion Performance of Stainless Steel Rebar
… specified by the Canadian Bridge Code (CAN/CSA-S6-06, 2006), however it is recommended that monitoring of these specimens be continued to ensure high corrosion rates and/or concrete cracking do not develop. As well, investigation into the effects crevice corrosion cells found in typical concrete …
-
Behaviour of Normal and High Strength Concrete Confined with Fibre Reinforced Polymers (FRP)
… FRP systems. Design equations from CSA S806-02 and CSA S6-06 provide reasonable and conservative estimates for the FRP-confined concrete strength. To calculate the peak strain for FRP-confined concrete, an equation based on the work by Berthet et al. (2006) is proposed.
-
Effet des séismes bidirectionnels sur la longueur d'appui des tabliers de ponts
… prescrite par la norme canadienne des ponts (CSA-S6-06) a été développée par la norme américaine AASHTO sur la base des séismes anticipés dans les régions de la côte ouest des États-Unis, considérées comme des zones à forte sismicité. Ce mémoire présente les résultats d’une étude analytique visant …
-
Effects of Surface Condition on the Corrosion Performance of Stainless Steel Rebar
… The Canadian Highway Bridge Design Code, CSA S6-06, specifies that reinforced concrete bridges should meet a service life of 75 years. It is concluded that, given the time required for concentrated chlorides to accumulate at the steel, the stainless steel rebar in the as-rolled condition would …
-
Bond and Flexural Behaviour of Self Consolidating Concrete Beams Reinforced and Prestressed with FRP Bars
… been fully studied. Furthermore, the ACI 440.1R-06 equation for determining the development length of FRP bars is based on Glass FRP (GFRP) bars and may not be applicable for Carbon FRP (CFRP) bars. This research program included an experimental and analytical study to investigate the flexural …