Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 27 for “"S806"”
-
Effect of GFRP-Concrete Bond Characteristics on the Flexural and Serviceability Behaviour of GFRP-RC Beams
… the development length equation in the CSA S806 (2012) standard. This study was performed by analyzing 431 beam-bond tests compiled from the literature. Based on a linear regression analysis, two development length equations were proposed to represent a modified form of the current CSA S806 …
-
Finite Element Modelling of FRP Reinforced Concrete Beams and Comparative Analysis of Current Strength Prediction Methods
… The models included in the analysis are the CSA S806-12, the ACI440.1R-15, the Japan Society of Civil Engineers (JSCE), and the Intelligent Sensing for Innovative Structures (ISIS) Canada Manual No. 3 shear models, as well as a prediction model proposed by Nehdi et al. (2007). The study concluded …
-
Experimental Investigation of the Shear Behaviour of Slender Concrete Beams Reinforced with GFRP
… and failure is concrete controlled. CSA S806 (2012) and ACI 440 (2003) provisions well predicted the failure loads of the test specimens and CSA S806 well predicted the governing mode of failure and deflections at service load levels. Existing stirrup spacing requirements in CSA S806 were …
-
Effect of Construction Contaminants on the Bond-Slip Behaviour of GFRP Reinforcing Bars
… Existing standards, such as CSA S807 and CSA S806, do not provide guidance on how contamination affects performance or how to treat contaminated GFRP reinforcing bars. In Ontario, exposed GFRP reinforcement contaminated by concrete splatter is required to be replaced, leading to costly delays …
-
GFRP-reinforced concrete exterior beam-column joints subjected to seismic loading
… of the relevant seismic provisions in the CSA/S806-12 (CSA 2012) was carried out and some recommendations were proposed for consideration in the future updates of the CSA/S806-12.
-
Flexural and Shear Behaviour of Fibre-Reinforced Concrete Beams Reinforced with GFRP Bars
… the deflection equations outlined in the CSA S806-12 and ACI 440.11-22 standards, alongside assessing flexural capacity in accordance with ACI 544.4R-18. Furthermore, digital image correlation (DIC) was utilized to capture the crack propagation, crack width, and deflection up to failure, …
-
Development Length and Bond Strength of FRP Bars Embedded in Normal, High Strength, and Ultra-High-Performance Concrete
… 23 db for the 8 mm bar. ACI440.1R-15 and CAN/CSA S806-12 design guides overestimated Ld of these small diameter bars. Alternative equations for splitting and pullout are proposed and explained herein. For the second study investigating sand coated GFRP bars, the embedment length was varied from 4 …
-
A GFRP Bar Bond Stress and Strength: Comparison of Beam-bond and Pullout Tests Results
… pullout specimens had, in accordance with CSA S806, 60 𝑚𝑚 embedment, or four times the bar nominal diameter. The first Modified pullout specimen experienced concrete splitting failure and as a result, the second was lightly confined and failed by GFRP bar rupture. All ten Standard pullout …
-
Bearing capacity, relaxation and finite element simulation for prestressed concrete beams reinforced with BFRP tendons
… 8110, Model code 2010, ACI 440.1R-06, CAN/CSA-S806-02, Nehdi et al, Fib and CNR-DT 203, regarding shear capacity, were compared with experimental results for nine beams. Many of these equations provided a rather conservative approach while equations from Nehdi et al and CAN/CSA-S806-02 gave the …
-
Acoustic emission monitoring of damage progression in fiber reinforced polymer rods
… applications. According to the CAN/CSA-S806-12 standard, the maximum recommended stress in FRP bars under service loads should not exceed 25% and 65% of the ultimate strength for glass FRP (GFRP) and carbon FRP (CFRP), respectively. These stress values are set to prevent creep failure in …
-
Behaviour of continuous concrete deep beams reinforced with GFRP bars
… achieved the minimum requirements of the CSA S806-12. The experimental results highlighted that the web reinforcement ratio improved the load capacities by about 10% and 18% for specimens having 𝑎/ℎ ratios of 1.0 and 1.7, respectively. For specimens with web reinforcement, the increase of 𝑎/ℎ …
-
Finite element analysis of CFRP prestressed concrete beams
… formulas shows that the formula given by the CSA S806-12 gives similar a/d dependency but lower values of shear resistance than the analysis.
-
Investigation of Shear-critical One-way Concrete Slabs Internally Reinforced with GFRP Bars
… including ACI440.1R-15, CAN/CSA S6-14, CAN/CSA S806-12, and previously suggested modifications incorporating 2nd orders of and θ. A new optimized equation was proposed for mid-depth longitudinal strain, and improvement was observed in the prediction of shear capacities compared with studied …
-
Investigation of Glass Fibre Reinforced Polymer (GFRP) Bars as Internal Reinforcement for Concrete Structures
… code-prescribed values for design (CSA S6, CSA S806, ACI440). An alternative bend-less system of shear reinforcement using straight double headed bars was successful as shear reinforcement but did however result in significant reductions to member deformability. A critical review of the various …
-
Shear Strengthening of RC Beams Using Externally Bonded and Anchored FRP U-wraps
… shear crack inclination angle in the CSA S806-12 (2012) standard led to overestimated shear resistance predictions for beams with a single shear crack, therefore a conservative 45 degree shear crack inclination is recommended for design. The use of the proposed carbon anchors resulted in a …
-
Behaviour of Normal and High Strength Concrete Confined with Fibre Reinforced Polymers (FRP)
… FRP systems. Design equations from CSA S806-02 and CSA S6-06 provide reasonable and conservative estimates for the FRP-confined concrete strength. To calculate the peak strain for FRP-confined concrete, an equation based on the work by Berthet et al. (2006) is proposed.
-
Towards Understanding the Seismic Behaviour of GFRP Confined Concrete Columns
… design provisions for FRP confinement in CSA-S806 (2012) was carried out. The code provisions were found to be ambiguous and lacking in several aspects. Based on the available test results, modifications to the current code were suggested.
-
Behaviour of continuous concrete slabs reinforced with FRP bars. Experimental and computational investigations on the use of basalt and carbon fibre reinforced polymer bars in continuous concrete slabs.
… concrete slabs tested. ISIS¿M03¿07 and CSA S806-06 equations reasonably predicted the deflections of the slabs tested. However, ACI 440¿1R-06 underestimated the deflections, overestimated the moment capacities at mid-span and over support sections, and reasonably predicted the load capacity …
-
Système d'ancrage en étriers fermés pour le renforcement à l'effort tranchant des poutres en béton armé à l'aide de composites en PRF
… les principaux manuels de conception, dont CSA-S806-12, CSA-S6-14, ACI 440.2R-08 et fib TG-9.3-01. Les résultats de cette étude montrent que les deux systèmes d’ancrage améliorent substantiellement la contribution du PRF à la résistance au cisaillement. Ils confirment également l’existence de …
-
Behaviour of GFRP-RC continuous deep beams without web reinforcement
… predicted values by the Canadian standards CSA/S806-12 (CSA 2012) and CSA/A23.3-14 (CSA 2014), and the American Code ACI 318-14 (ACI 2014). The test results confirmed the formation of the Strut-and Tie-Model (STM). In addition, it was observed that increasing the shear span-to-depth ratio and …
Page 1 of 2