  1. Study of Microbiologically Influenced Corrosion Using Electrochemical Techniques in Oil and Gas Systems

    … introduces Split Cell Zero Resistance Ammetry (SC-ZRA) as an innovative method for studying and monitoring MIC in oil and gas systems. Unlike conventional techniques, SC-ZRA is passive, providing insights into MIC without disturbing the microbial corrosion process. SC-ZRA also allows for …

    ohiolink Repository record for Study of Microbiologically Influenced Corrosion Using Electrochemical Techniques in Oil and Gas Systems (opens in a new tab)

  2. ELECTROCHEMICAL MONITORING OF CORROSIVE MICROBIOLOGICAL ACTIVITIES USING SPLIT-CELL ZERO RESISTANCE AMMETRY

    … using split-chamber zero-resistance ammetry (SC-ZRA). Microbial cultures were enriched from natural gas pipeline samples, focusing on fermentative and sulfur-metabolizing bacteria, and their corrosion activities were evaluated using SC-ZRA.Chapter I reviewed the threat corrosion posed to …

    ohiolink Repository record for ELECTROCHEMICAL MONITORING OF CORROSIVE MICROBIOLOGICAL ACTIVITIES USING SPLIT-CELL ZERO RESISTANCE AMMETRY (opens in a new tab)

  3. Investigating the Electrochemical Interaction of Microorganisms with MetalSurfaces During Microbiologically Influenced Corrosion

    … using the split-cell zero resistance ammetry (SC-ZRA) technique. Flow chamber is developed as a quick tool in the lab to determine how MIC is affected inside of pipelines in the presence of microorganisms under hydrodynamic conditions in oxygen-limited and oxygen non-limited conditions. Mass …

    ohiolink Repository record for Investigating the Electrochemical Interaction of Microorganisms with MetalSurfaces During Microbiologically Influenced Corrosion (opens in a new tab)

  4. Electrochemical Monitoring of Biocide Efficacy Within SRB-Induced Corrosion of Carbon Steel

    … split chamber-zero resistance ammetry (SC-ZRA) incubations have validatedreal-time electrochemical monitoring of SRB-induced MIC. With electrochemicalmonitoring of MIC being obtainable, the next step is to determine if electrochemicalmonitoring of the methods used to mitigate MIC are …