Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 88 for “"SEMG signals"”
-
Perturbation Based Decomposition of sEMG Signals
… records the motor unit action potential signals in the vicinity of the electrode to reveal information on muscle activation. Decomposition of sEMG signals for characterization of constituent motor unit action potentials in terms of amplitude and firing times is useful for clinical …
-
Muscle Force Estimation and Fatigue Detection Based on sEMG Signals
Three relationships, surface electromyography (sEMG) amplitude-force relationship, mean frequency (MF) and force relationship, and the relationship between frequency parameters and signal energy distribution (MF-power relationship) are first investigated. These relationships are nonlinear from both …
-
Deep learning and sEMG signals based human hand gesture recognition
… converting the raw surface electromyograph (sEMG) signals from amputeeswith different hand amputation levels and able-bodied people into heatmaps, with anapplied properly designed convolution neural network which extracts and learns thefeatures contained within the heatmaps, the mis-trigger …
-
FDR-controlled network modeling and analysis of fMRI and sEMG signals
… (fMRI) and surface electroencephalography (sEMG) provide great potential to studying the underlying neural systems and the related diseases. A broad range of statistical methods have been developed to model interactions between neural components. In this thesis, a false discovery rate …
-
Identification of Femoral-Acetabular Symptoms Using sEMG Signals During Dynamic Contraction
… wavelet transform method was used to analyze sEMG signals. The Bior3.9 WF was selected as it provided higher amount of energy for most of the subjects and then the wavelet power spectrum was computed for healthy control and FAI groups. The results show that the RF muscle is more active in the …
-
Identification of muscle activation schemes by inverse methods applied on HD-sEMG signals
… des méthodes inverses sur les signaux HD-sEMG (électromyogramme de surface à haute densité) à partir d'une grille placée sur le Biceps Brachial (BB). À cette fin, nous proposons une approche innovante, qui implique l'utilisation de la méthode inverse classique de minimisation de norme et …
-
Deep Learning Methods for Hand Gesture Recognition via High-Density Surface Electromyogram (HD-sEMG) Signals
… Recognition (HGR) using surface Electromyogram (sEMG) signals can be considered as one of the most important technologies in making efficient Human Machine Interface (HMI) systems. In particular, sEMG-based hand gesture has been a topic of growing interest for development of assistive systems to …
-
The Effects of Varying Fibre Composition on Simulated SEMG Signals in the Time and Frequency Domains
Whether SEMG can be used as a tool to estimate muscle fibre type concentrations remains an interesting question in muscle physiology. It is speculated that fast twitch motor units may have increased conduction velocities and that this may lead to an increased SEMG mean power frequency when compared …
-
Classification of sEMG signals and Motion data using learning algorithms with application to post-stroke impairment
… by the subject using their bio & kinematic signals. To develop the ideal network for this goal, the thesis initially compares various classic learning techniques used to classify hand gestures using surface-Electromyography(sEMG). From the results obtained from these networks, a CNN is …
-
Entropy and Fractal Dimension of the Surface Electromyographic Signals During Swallowing
… dimension) of the Surface Electromyogram (SEMG) signals obtained during swallowing. SEMG signals were obtained from 20 normal human subjects during dry swallow, wet-thin swallow and wet-thick swallow. The SEMG signals were processed and their fractal dimension and entropy were calculated. …
-
Extraction of Electrocardiography Artefacts From Surface Electromyography Signals Using Continuous Wavelet Transform
The study of biosignals such as Electromyography (EMG) and Electrocardiography (ECG) signals is significant within the physiological and medical field for diagnosis and rehabilitation purposes. The extraction of features from these signals by analysing them can be used to understand the …
-
Analysis of factors influencing the stationarity of surface electromyography signals measured in non-fatigued shoulder muscles
… the % stationarity of surface electromyography (SEMG) signals with respect to the initial or fresh condition is used to predict localized muscle fatigue. However, factors other than muscle fatigue can also influence the stationarity of SEMG signals. This study was aimed at analyzing the effect of …
-
Wavelet Analysis and Classification Surface Electromyography Signals
… an intelligent surface electromyography (SEMG) signal classifier. An intelligent SEMG signal classifier would be used for recognising and treatment of musculoskeletal pain and some neurological disorders by physiotherapists and occupational therapists. SEMG signals displays the electrical …
-
Predicting muscle fatigue during dynamic contractions using wavelet analysis of surface electromyography signals
… frequency of the surface electromyography (sEMG) signals are the most commonly used spectral variables that are considered the gold standard for muscle fatigue assessment, especially in static contractile conditions, where the sEMG signal can be assumed as stationary. However, detecting and …
-
Advancements In Biosignal Analysis For Models of Musculotendon Actuators. Ultrasound B-Mode Imaging for Tendon Stiffness Estimation and sEMG Forward Modelling for In Vivo Innervation Zone Tracking
… three key contributions to the analysis of biosignals recorded from the musculotendon actuator of the human arm. It focuses specifically on surface electromyography (sEMG) signals and ultrasonic measurements of the myotendinous junction. The overarching objective is to advance prediction models …
-
Controle de força de uma prótese mioelétrica de mão com realimentação sensorial
… of tactile fibers. Surface Electromyographic (sEMG) signals were recorded in healthy participants, performing sustained contractions of hand grasp, in different force levels. Those signals were used in the implementation of a force estimator considering two methods. A proportional control with …
-
Machine Learning for Predicting Prosthetic Limb Movements
… limb movement from surfaced electromyography (sEMG) signals using sequence learning techniques. sEMG signals change over time due to multiple factors such as muscle fatigue or user variability. Traditional prosthetics control methods rely on static feature extraction, ignoring how signals …
-
Development of a New Multi-Channel Electrode and Signal Processing for Surface Electromyography Signals Feature Extraction
… and develop signal processing techniques for sEMG signals, in order to enable the extractions of more useful-features. Analysis of these signal features will assist in the creation of a more effective database for diagnosing muscle ailments and conditions. The investigation was carried out by …
-
Design, Dynamics, and Control of Active-passive Upper-limb Exoskeleton Robots
… estimator using surface electromyography (sEMG) biological signals as input, 5) an efficient assist-as-needed (AAN) hierarchical control scheme of upper-limb power assist exoskeletons, and 6) a short-term experimental human-in-the-loop (HITL) evaluation of sEMG-based machine learning-driven …
Page 1 of 5