  1. BACKSIDE SAMPLE PREPARATION ON BULK SUBSTRATE FOR SECONDARY ION MASS SPECTROSCOPY (SIMS) ANALYSIS

    Secondary ion mass spectrometry (SIMS) is an effective and powerful analytical technique that is widely used in semiconductor industry. With the continuing shrinking of the devices, quantification of dopant concentration profile, especially at the interface become increasing important in …

    nus Repository record for BACKSIDE SAMPLE PREPARATION ON BULK SUBSTRATE FOR SECONDARY ION MASS SPECTROSCOPY (SIMS) ANALYSIS (opens in a new tab) Download file for BACKSIDE SAMPLE PREPARATION ON BULK SUBSTRATE FOR SECONDARY ION MASS SPECTROSCOPY (SIMS) ANALYSIS (opens in a new tab)

  2. Design of Polymer Composites With Improved Adhesion and Wear Properties

    … compared to a commercial PTFE based coating. TOF-SIMS analysis showed that ZonylRTM particles had migrated down into the coating at least 1.5 microm deep when the wear track was only 0.2 microm deep, which means that a ATSP and Zonyl RTM composite had formed due to pressure and sliding. It is …

    uiuc Repository record for Design of Polymer Composites With Improved Adhesion and Wear Properties (opens in a new tab)

  3. Identification and imaging different lipid species within phase-separated model membranes by integration of TOF-SIMS and principal component analysis

    … of flight secondary ion mass spectrometry (TOF-SIMS) enables chemically imaging the distributions of various lipid species in model membranes. However, discriminating the TOF-SIMS spectra of structurally similar lipids is very difficult because the low mass fragment ions that are abundant in the …

    uiuc Repository record for Identification and imaging different lipid species within phase-separated model membranes by integration of TOF-SIMS and principal component analysis (opens in a new tab)

  4. Oxygen and hydrogen isotopic analysis of tourmaline by secondary ion mass spectrometry

    … To obtain accurate isotopic measurements using SIMS, it is important to select chemically similar standards and samples to correct for both matrix effects and instrumental mass fractionation (IMF), collectively termed instrumental mass bias (IMB). For certain mineral groups (e.g. tourmalines), …

    manitoba Repository record for Oxygen and hydrogen isotopic analysis of tourmaline by secondary ion mass spectrometry (opens in a new tab)

  5. Reduced boron diffusion under point defect injection in fluorine implanted silicon

    … from the surface influences the fluorine SIMS peaks and the diffusion of boron marker layers which are placed to coincide with major fluorine peaks of the fluorine profile. SIMS analysis of a sample implanted with 185keV, 2.3 x 10<sup>15</sup> cm<sup>-2</sup> F<sup>+</sup> and annealed at …

    soton Download PDF for Reduced boron diffusion under point defect injection in fluorine implanted silicon (opens in a new tab)

  6. A study on the impact of surface and bulk oxidation on the recyclability of NdFeB magnets

    … the resistance to oxidation of NdFeB magnets. SIMS analysis showed that oxygen was concentrated in the grain boundary phase in the near surface. The oxygen content was shown to increase almost linearly throughout the recycling process outlined in this report with an overall increase of …

    birmingham Download PDF for A study on the impact of surface and bulk oxidation on the recyclability of NdFeB magnets (opens in a new tab)

  7. An integrated structural and geochemical study of auriferous sheeted quartz veins within the 2740 Ma Côté Gold deposit, Swayze Greenstone Belt, Ontario

    … with a Au-Cu-Te-Pb-Bi-S association. In situ SIMS analysis of δ34S and δ18O are consistent with a magmatic signature for the fluid with a minor component of seawater, and supports the previously proposed high-level, subaqueous setting for the deposit. The combination of temporal, spatial, and …

    laurentian Repository record for An integrated structural and geochemical study of auriferous sheeted quartz veins within the 2740 Ma Côté Gold deposit, Swayze Greenstone Belt, Ontario (opens in a new tab)

  8. Depositional environment and hydrothermal-diagenetic history of pre-salt carbonate in an Early Cretaceous rifted basin, offshore Brazil

    … are recognized. Secondary Ion Mass Spectrometry (SIMS) analysis was designed to measure the δ18O and δ13C of the three zones, providing insight into the lake water chemistry and temperature changes from the surface to bottom during the deposition of dolomite and the early burial. Diagenetic …

    regina Repository record for Depositional environment and hydrothermal-diagenetic history of pre-salt carbonate in an Early Cretaceous rifted basin, offshore Brazil (opens in a new tab)

  9. Electrical Conductivity of the Aluminum Oxide Diffusion Barrier Following Catalytic Carbon Nanotube Growth

    … measurements, electron microscopy, XEDS, and SIMS analysis are used to characterize the various samples and determine the process responsible for the observed phenomenon. Through these techniques, it is determined exposure to ethylene gas during the CNT growth recipe used in our lab, …

    byu Repository record for Electrical Conductivity of the Aluminum Oxide Diffusion Barrier Following Catalytic Carbon Nanotube Growth (opens in a new tab) Download PDF for Electrical Conductivity of the Aluminum Oxide Diffusion Barrier Following Catalytic Carbon Nanotube Growth (opens in a new tab)

  10. Diamond Intracrystalline Stable Isotope Chemical Image Analysis by Time-of-Flight Secondary Ionization Mass Spectrometery

    … mantle keel of a cratonic nuclei. Through analysis of stable isotopes, radiogenic isotopes and trace elements, diamond geochemical analyses can define chemical fluxes in the mantle keel. However, such studies require multiple methodologies for each chemical suite, high spatial resolution …

    mo-state Repository record for Diamond Intracrystalline Stable Isotope Chemical Image Analysis by Time-of-Flight Secondary Ionization Mass Spectrometery (opens in a new tab)

  11. Surface characterization of biomass by imaging mass spectrometry

    … recalcitrance. Imaging mass spectrometry by TOF-SIMS and MALDI-IMS is applied to understand detailed spatial and lateral changes of major components in the surface of biomass under submicron scale. Using TOF-SIMS analysis, we have demonstrated a dilute acid pretreated poplar stem represented …

    gatech Repository record for Surface characterization of biomass by imaging mass spectrometry (opens in a new tab)

  12. Secondary ion mass spectrometer geochemical analysis of secondary infilled areas in stylaster erubescens;

    … values using secondary ion mass spectrometry (SIMS) on the micrometer scale. SIMS analysis determined that nine of the eleven infilled areas have δ;18;O values within analytical precision (±0.4 , 2σ) of the adjacent primary skeleton. The two infilled areas with differences in primary and …

    alabama Repository record for Secondary ion mass spectrometer geochemical analysis of secondary infilled areas in stylaster erubescens; (opens in a new tab)

  13. Using High Performance Additives in Fused Filament Fabrication to Improve Mechanical Properties

    … of PPO at low loading levels. Furthermore, ToF-SIMS analysis was conducted to assess the dispersion of PPO in the matrix polymers (ASA and ABS) at various loading levels. The results from this study strongly suggest that PPO is well distributed on the surface of the printed specimens. This …

    utk-theses Repository record for Using High Performance Additives in Fused Filament Fabrication to Improve Mechanical Properties (opens in a new tab)

  14. Development of impedimetric biosensors based on phage-modified microarrays, for the direct and spedific detection of bacteria

    … immobilization were confirmed using XPS and TOF-SIMS analysis. The phage-modified SPEs were then used to specifically detect target bacteria. Impedance measurements in the form of Nyquist plots (imaginary impedance (Z i ) versus real impedance (Z r )) show shifts due to binding of the bacteria to …

    concordia Download PDF for Development of impedimetric biosensors based on phage-modified microarrays, for the direct and spedific detection of bacteria (opens in a new tab)

  15. Correlation of ToF-SIMS surface analysis with particle hydrophobicity and flotation

    … Secondary Ion Mass Spectrometry (ToF-SIMS) and statistically correlated with hydrophobicity, as measured by the water contact angle. A statistical linear model has been derived that calculates the contact angle based on the surface chemical contribution of key ToF-SIMS secondary ion …

    adelaide Repository record for Correlation of ToF-SIMS surface analysis with particle hydrophobicity and flotation (opens in a new tab)

  16. Oxidation and morphology of iron and iron alloy droplets.

    … revealed by Scanning Electron Microscopy and to SIMS analysis of the thin surface oxide films, and mechanisms are proposed for each system.A mathematical model has been developed which simulates the mass transfer of oxygen by forced convection to an accelerating molten iron droplet. The model …

    sheffield-hallam Download PDF for Oxidation and morphology of iron and iron alloy droplets. (opens in a new tab)

  17. Silicon molecular beam epitaxy

    … CV profiling. Auger electron surface analysis, transmission electron microscopy (TEM), secondary ion mass spectroscopy (SIMS) analysis, spreading resistance measurement, and photoluminescence. The basic material grown was found to be of high quality and comparable to the Si-MBE …

    london-metro Download PDF for Silicon molecular beam epitaxy (opens in a new tab)

  18. Material Characterisation and Interface Optimisation of Recycled Carbon Fibre Composites

    … and interfacial performance. XPS and ToF-SIMS analysis showed that there was almost complete coverage of the veil by the binder in the veil-making process, and that silicon contamination on the fibre itself is likely silica based, and that silicon present in the binder is PDMS.

    whiterose Download PDF for Material Characterisation and Interface Optimisation of Recycled Carbon Fibre Composites (opens in a new tab)

  19. Si-MOS Multiplexer and Depletion Mode Charge Sensor for Quantum Computation

    … by the addressing switches. The results of SIMS analysis showed that the p-type channel stoppers had a lower doping concentration and shallower profile than the design, which could cause leakages. On the other hand, the results of the depletion mode charge sensor demonstrated that the device …

    unsw Repository record for Si-MOS Multiplexer and Depletion Mode Charge Sensor for Quantum Computation (opens in a new tab)