Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 354 for “"SPAD"”.

  1. Advanced techniques for SPAD-based CMOS d-ToF systems

    … (d-ToF) with single photon avalanche diodes (SPADs) integrated into a standard CMOS process result in a high interest for development from both researchers and market stakeholders. Despite the net advantages of SPAD-based CMOS d-ToF systems over other techniques, still many challenges have to …

    trento Repository record for Advanced techniques for SPAD-based CMOS d-ToF systems (opens in a new tab)

  2. Single-Pass Albumin Dialyse (SPAD) zur Therapie des akuten Leberversagens

    … Single-Pass Albumin Dialyse (SPAD) wird im akuten Leberversagen verwendet. Im Rahmen von In-vitro- Versuchsreihen im Sinne einer Dosisfindungsstudie wurden die Parameter Albuminkonzentration und Dialysatflussgeschwindigkeit evaluiert, um ein möglichst effizientes und …

    fu-berlin Repository record for Single-Pass Albumin Dialyse (SPAD) zur Therapie des akuten Leberversagens (opens in a new tab)

  3. Development of Image and Video Processing Software for Spad Lidar Imagers

    Advanced imaging systems require complex hardware, optical setups, and software to collect and process data. In applications such as autonomous vehicles and aerial imaging, a large amount of data is collected and must be processed accurately and quickly. As a result, different methods exist for …

    alabama Repository record for Development of Image and Video Processing Software for Spad Lidar Imagers (opens in a new tab)

  4. Novel tools for in vivo fluorescence lifetime imaging using miniaturised SPAD arrays

    … miniaturised single-photon avalanche diode (SPAD) arrays. FLIm can enhance biochemical specificity by enabling discrimination between fluorophores with overlapping emission spectra but distinct fluorescence lifetimes (FLT). It is also sensitive to the local molecular environment, making it …

    cork Repository record for Novel tools for in vivo fluorescence lifetime imaging using miniaturised SPAD arrays (opens in a new tab)

  5. Geração de zonas de manejo para cafeicultura usando sensor SPAD e análise foliar

    … A amostragem para a coleta dos valores de SPAD foi feita de forma alternada em relação às linhas de plantio, e nessas linhas, a cada quatro plantas foi amostrada uma, totalizando-se 25% de todas as plantas presentes nas linhas e 1145 plantas em toda a área. Foi realizada a coleta de folhas …

    brazil-ufv Repository record for Geração de zonas de manejo para cafeicultura usando sensor SPAD e análise foliar (opens in a new tab)

  6. Design and characterisation of SPAD based CMOS analog pixels for photon-counting applications

    … the same time. Single- Photon Avalanche Diodes (SPADs) have proved their prospectives in terms of shot-noise limited operation, excellent timing resolution and wide spec- tral range. Nonetheless, the performance of recently presented SPAD based arrays has an issue of low detection efficiency by …

    trento Repository record for Design and characterisation of SPAD based CMOS analog pixels for photon-counting applications (opens in a new tab)

  7. An InGaAlAs-InGaAs two-colour detector, InAs photodiode and Si SPAD for radiation thermometry

    … using a Si single photon avalanche photodiode (SPAD). In addition to research in these detectors, a Monte Carlo model for modelling impact ionisation in Si was also developed. InGaAlAs is attractive material for multi-colour detection at wavelengths up to 1.7 m, as it is lattice matched to InP …

    whiterose Download PDF for An InGaAlAs-InGaAs two-colour detector, InAs photodiode and Si SPAD for radiation thermometry (opens in a new tab)

  8. RO-Based TDC Design with Configurable Resolution and Power for SPAD-Based TCSPC LiDAR Applications

    Single-photon avalanche diodes (SPAD) are used to measure time-of-flight (ToF) using CMOS time-to-digital Converters (TDCs) for compact, low-cost, and highly integrated three-dimensional (3D) sensing. The TDC specifications are critical determinants of the system's range, resolution, and accuracy. …

    toronto-retro Repository record for RO-Based TDC Design with Configurable Resolution and Power for SPAD-Based TCSPC LiDAR Applications (opens in a new tab)

  9. Development of Time-Resolved Diffuse Optical Systems Using SPAD Detectors and an Efficient Image Reconstruction Algorithm

    … free-running (FR) and time-gated (TG) SPAD detectors that are fabricated in low-cost standard CMOS technology instead of the costly photon counting and timing detectors. The FR-TR-DOS prototype has demonstrated comparable performance (for homogeneous objects measurements) with the …

    mcmaster Repository record for Development of Time-Resolved Diffuse Optical Systems Using SPAD Detectors and an Efficient Image Reconstruction Algorithm (opens in a new tab)

  10. Design of a Time-to-Digital Converter and Multi-Time-Gated SPAD Arrays Towards Biomedical Imaging Applications

    … (dSiPMs) and single-photon avalanche diode (SPAD) imagers are optical sensing systems formed from the integration of time-to-digital converters (TDCs) with arrays of highly sensitive photodetectors known as SPADs. TDCs are high-performance mixed-signal circuits capable of timestamping events …

    mcmaster Repository record for Design of a Time-to-Digital Converter and Multi-Time-Gated SPAD Arrays Towards Biomedical Imaging Applications (opens in a new tab)

  11. Real-Time-Capable Algorithms for SPAD Array Flash LiDAR Data of Targets Collected in Clear and Obscured Environments

    … using a 32x32 Single Photon Avalanche Diode (SPAD) rectangular planar array 3D flash direct Time-of-Flight (dToF) Light Detection and Ranging (LiDAR) system. Different algorithms are presented for data collected in different environments. For data collected in air, a real-time target …

    anu Repository record for Real-Time-Capable Algorithms for SPAD Array Flash LiDAR Data of Targets Collected in Clear and Obscured Environments (opens in a new tab)

  12. Estado de nitrogênio, índice SPAD, teor de açúcar e produtividade de genótipos de milho doce (Zea Mays L. Saccharata) em função de doses de nitrogênio

    … a produtividade de espigas, valores do índice SPAD, teor de nitrogênio na folha em diferentes estádios de desenvolvimento da planta e teores de açúcares nos grãos de milho doce. Quatro experimentos foram realizados. No experimento I, o híbrido FT 2015 foi utilizado e a semeadura ocorreu em 30 …

    brazil-ufv Repository record for Estado de nitrogênio, índice SPAD, teor de açúcar e produtividade de genótipos de milho doce (Zea Mays L. Saccharata) em função de doses de nitrogênio (opens in a new tab)

  13. Utilizacion del clorofilometro SPAD-502 para diagnosticar la deficiencia del nitrogeno en sorgo (Sorghum bicolor L. Moench) bajo distintas dosis de nitrogeno San Ramon Matagalpa

    … trabajo fue evaluar el uso del clorofilometro (SPAD - 502) y diagnosticar la deficiencia del nitrógeno en el cultivo de sorgo ( Sorghum bicolor L. Moench.), en la época de postrera (2005 – 2006), en el Municip io de San Ramón, Matagalpa. Se estudió una línea (ICVLM 92 522), del programa …

    una Download PDF for Utilizacion del clorofilometro SPAD-502 para diagnosticar la deficiencia del nitrogeno en sorgo (Sorghum bicolor L. Moench) bajo distintas dosis de nitrogeno San Ramon Matagalpa (opens in a new tab)

  14. Single photon avalanche diodes for visible light communication

    … to create a single photon avalanche diode (SPAD). It is expected that the SPAD can be used to develop the more sensitive VLC receiver.</p> <p>At present, the sensitivity of the current SPADs is limited by several non- idealities, and the circumstances in which the SPADs should be preferred …

    oxford Repository record for Single photon avalanche diodes for visible light communication (opens in a new tab)

  15. Time-Controlled CMOS Single-Photon Avalanche Diodes Receivers Towards Optical Wireless Communication Applications

    Single-photon avalanche diodes (SPADs) capable of single photon detection are promising optical sensors for use as receivers in optical wireless communication (OWC) systems. In SPAD-based receivers, the intersymbol interference (ISI) effect caused by dead time is an important drawback that limits …

    mcmaster Repository record for Time-Controlled CMOS Single-Photon Avalanche Diodes Receivers Towards Optical Wireless Communication Applications (opens in a new tab)

  16. DESIGN OF A TIME-AMPLIFIED, STOCHASTIC PHASE INTERPOLATION TIME-TO-DIGITAL-CONVERTER FOR BIOMEDICAL IMAGING APPLICATIONS

    … (TDC) and single-photon avalanche diodes (SPAD) can be integrated together into SPAD-imagers. TDC is a mixed-signal circuit that can convert the time differences between the two input signals. In SPAD-imagers, the electrical pulses triggered by incident photons are measured against the …

    mcmaster Repository record for DESIGN OF A TIME-AMPLIFIED, STOCHASTIC PHASE INTERPOLATION TIME-TO-DIGITAL-CONVERTER FOR BIOMEDICAL IMAGING APPLICATIONS (opens in a new tab)

  17. Critérios para o manejo da adubação nitrogenada do tomateiro em ambiente protegido e no campo

    … o critério do nível crítico do índice SPAD para definir a necessidade de N (SPAD-1); 2) igual ao anterior utilizando-se o valor crítico do índice SPAD aumentado em 20% (SPAD-2); igual ao tratamento 1 porém com o valor crítico do índice SPAD diminuído em 10% (SPAD-3); o índice SPAD foi …

    brazil-ufv Repository record for Critérios para o manejo da adubação nitrogenada do tomateiro em ambiente protegido e no campo (opens in a new tab)

  18. Visible light communications with single-photon avalanche diodes

    … the use of single-photon avalanche diodes (SPADs) for visible light communications (VLC). The high sensitivity of SPADs can potentially enhance the performance of VLC receivers. However, a SPAD-based system has challenges that need to be addressed before it can be considered as a viable …

    oxford Repository record for Visible light communications with single-photon avalanche diodes (opens in a new tab)

  19. The effects of Sopite Syndrome on self-paced airsickness desensitization program

    … the Self-Paced Airsickness Desensitization (SPAD) program in 1989 for aviation students whose incidence of airsickness was not easily resolved. Some participants may have also experienced symptoms that are not typically recognized as motion sickness, including prolonged drowsiness and/or mood …

    nps Repository record for The effects of Sopite Syndrome on self-paced airsickness desensitization program (opens in a new tab)

Page 1 of 18