Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 74 for “"SPIM"”
-
Acoplamento SPIM-FEM adaptativo para modelos de degradação elástica
… between the smoothed point interpolation method (SPIM) and the finite element method (FEM). This coupling is performed using different smoothing strategies: cell-based, edge-based, or node-based, without any restriction for the adoption of the point interpolation method (PIM) to build the shape …
-
Adaptive fem-spim coupling for phase-field modelling of fracture
… sem malha Smoothed Point Interpolation Method (SPIM), para a discretização de modelos de phase-field aplicados ao problema de propagação de trincas. Para essas aplicações, a formulação fraca-enfraquecida, adotada para o problema de deslocamentos no SPIM, foi estendida para o problema de …
-
3D high-content screening imaging of organoid development using single objective SPIM
… feuille de lumière à objectif unique, appelée soSPIM. Cette méthode d'imagerie repose sur des dispositifs micro-fabriqués composés de micromiroirs orientés à 45° permettant de créer une feuille de lumière perpendiculaire à l’axe optique du microscope, et de collecter la fluorescence avec le même …
-
OPTO-MECA-SPIM : imagerie dynamique et interactive de phénomènes mécanobiologiques dans les tissus
… le Selective Plane Illumination Microscope (SPIM), un de ses variants, représente un outil de choix pour observer et imager avec une haute résolution spatio-temporelle ces structures assimilées à des tissus (TM). Bien que le SPIM est un outil puissant, il souffre de phénomènes tels que la …
-
Depth Limit of Imaging through Scattering Media using Selective Plane of Illumination Microscopy (SPIM)
… Selective Plane of Illumination Microscopy (SPIM) has emerged as an alternative 3D microscopy technique with faster image acquisition speeds, enabled by capturing entire 2D planes rather than individual points. While the advantages of SPIM for high speed imaging are understood, here we …
-
Multiscale analysis of pressurized fractures - an approach based on phase-field models and adaptive FEM-SPIM coupling
… sem malha Smoothed Point Interpolation Method (SPIM). A abordagem evolui de um acoplamento prescrito para uma estratégia adaptativa e automatizada, na qual o SPIM é empregado em regiões de fratura ativa, onde refinamento adaptativo é conduzido, guiado por critérios associados à variável de …
-
QUANTITATIVE THREE-DIMENSIONAL (3D) MAPPING OF BIOMOLECULAR DYNAMICS AND ORGANIZATION IN VITRO AND IN VIVO BY SPIM-FCS
… of single plane illumination microscopy (SPIM-FCS) was established to determine spatial maps of diffusivity of biomolecules in vitro and in vivo. Sub-resolution membrane distribution of biomolecules was also investigated by applying FCS diffusion law analysis to SPIM-FCS data. These …
-
Imaging mobility and interaction of c-Fos and c-Jun transcription factors in live cells: A SPIM-FCCS study
… series is single plane illumination microscopy (SPIM). SPIM illuminates the fluorescently labeled sample by a thin light sheet formed by a laser beam focused through cylindrical optics and simultaneously images all points in the two-dimensional field of view with a fast camera. SPIM-FCCS uses two …
-
Asymmetric cell division in the drosophila embryonic neuroblast
A novel coiled-coil protein, Spindle Miranda (Spim) or Drosophila CG9646 protein, was isolated from a microarray screen for potential effectors of telophase rescue in the insc mutant background. Both Spim and Insc are positively regulated by the Snail family of transcription factors. Single mutants …
-
Towards a smarter light sheet microscope
Selective plane illumination microscopy (SPIM) is becoming the method of choice for long-term 3D fluorescence imaging thanks to its low photo-toxicity and high imaging speed. However, SPIM is very data intensive: A single SPIM experiment can easily generate terabytes of image data, which is often …
-
Numerical aspects of the application of smoothed point interpolation methods in computational geomechanics
… aspects of smoothed point interpolation methods (SPIM) in computational geomechanics. The extension of SPIM to flow-deformation analysis of saturated porous media is formulated. The singularity problem encountered when original SPIM formulation is applied to axisymmetric setting is addressed. The …
-
Mesoscopic 3D Quantitative Imaging: Attenuation Correction with OPTiSPIM
… with selective plane illumination microscopy (SPIM) in a hybrid setup (OPTiSPIM). In contrast to SPIM, that relys on fluorescent contrast, OPT can reconstruct data from absorbing contrast. Apart from having registered multimodal datasets by fusing data from different contrast mechanisms, the …
-
Mapping Diffusion Properties in Living Cells
… it with light sheet fluorescence microscopy (SPIM). This relatively new widefield microscopy technique allows to observe an arbitrarily positionable, thin plane (diameter: 1-3µm) in the cell. By using a fast electron-multiplying charge-coupled device camera, the combination of SPIM and FCS …
-
RESOLFT Light-sheet Microscopy
… of a selective plane illumination microscope (SPIM), that illuminates only a thin section of a sample perpendicular to the detection axis and thus reduces the overall light exposure in volume recordings. The symbiotic combination of RSFP-based RESOLFT and SPIM, the so called RESOLFT-SPIM …
-
Blood flow measurement in the zebrafish heart using light sheet microscopy
… selective plane illumination microscopy (SPIM), with optical gating techniques, and micro particle image velocimetry (uPIV). This combination (referred here as SPIM-uPIV) allowed non-invasively measuring blood flow in the developing zebrafish heart in a depth and time-resolved manner. Our …
-
Light sheet based fluorescence correlation and cross-correlation spectroscopy for quantitative measurements of bio-molecules in live cells
… (single plane illumination microscopy - SPIM) and fluorescence correlation and cross-correlation spectroscopy (FCS and FCCS). SPIM-FCS/SPIM-FCCS allows measuring concentration, diffusion, transport, and interactions maps in a true imaging mode with single molecule sensitivity. The method …
-
A versatile light-sheet microscope, platform for advanced 3D fluorescence imaging and research
… on the specimen. This work presents the SLM-SPIM, a Selective Plane Illumination Microscope (SPIM, a cylindrical-lens-based light-sheet microscope) with a phase-only Spatial Light Modulator (SLM) integrated into its illumination arm. The SLM is placed in a Fourier plane, and it can be used to …
Page 1 of 4