Showing 1 to 20 of 42 for “"SSFP"”.

  1. Development of Fully Balanced Ssfp and Computer Vision Applications For Mri-Assisted Radiosurgery (Mars)

    Prostate cancer is the second most common cancer in men and the second-leading cause of cancer death in men. Brachytherapy is a highly effective treatment option for prostate cancer, and is the most cost-effective initial treatment among all other therapeutic options for low to intermediate risk …

    uthsc Repository record for Development of Fully Balanced Ssfp and Computer Vision Applications For Mri-Assisted Radiosurgery (Mars) (opens in a new tab)

  2. Exploring multi-wavelength single-shot Fourier ptychography (SSFP) as a technique for ultrafast pulsed laser (UPL) characterization

    … and amplitude of two discrete wavelengths using SSFP, I present my work as a proof-of-concept toward an exciting new way for non-experts to characterize UPLs. In this thesis I will introduce readers to computational imaging via Fourier ptychography, and provide the details regarding system …

    colo-mines Repository record for Exploring multi-wavelength single-shot Fourier ptychography (SSFP) as a technique for ultrafast pulsed laser (UPL) characterization (opens in a new tab)

  3. An Analysis of the Linked-pulse in Steady-state Free Precession in MRI

    The steady-state free precession (SSFP) is one type of the fast scanning technique in MRI. So far most of its analysis are concentrated on the gradient echo SSFP (GR SSFP), very few paper discuss the spin echo SSFP (SE SSFP), and they are usually based on the simplified the hard pulse assumption. …

    portland-state Repository record for An Analysis of the Linked-pulse in Steady-state Free Precession in MRI (opens in a new tab)

  4. Analyse der Myokardbewegung mit SSFP-Tagging am MRT: Optimierung der Akquisitionsparameter und Methodenvergleich für 1,5 T und 3 T

    … dass die Tagging-Bildgebung für 1,5 T mittels SSFP (Steady State Free Precession) der Radiofrequenz „spoiled“ Gradientenecho-Bildgebung in den Punkten Signal-zu-Rausch-Verhältnis (SNR), Blut-Gewebe-Kontrast und Tag-Persistenz überlegen ist. In unserer Arbeit wurde die Anwendbarkeit und der …

    freiburg-diss Repository record for Analyse der Myokardbewegung mit SSFP-Tagging am MRT: Optimierung der Akquisitionsparameter und Methodenvergleich für 1,5 T und 3 T (opens in a new tab)

  5. Vergleich unterschiedlicher Late-Gadolinium-Enhancement Techniken bei verschiedenen kardialen Erkrankungen mittels kardiovaskulärer Magnetresonanztomographie

    … eine multi-slice steady-state free precession (SSFP)-IR-Sequenz in Atemanhalte sowie eine multi-slice SSFP-PSIR- Sequenz sowohl in Atemanhalte (bh) als auch in freier Atmung (nonbh). Die Bilddaten wurden hinsichtlich qualitativen (Bildqualität, Signal- und Contrast-to- Noise-Ratio) und …

    fu-berlin Repository record for Vergleich unterschiedlicher Late-Gadolinium-Enhancement Techniken bei verschiedenen kardialen Erkrankungen mittels kardiovaskulärer Magnetresonanztomographie (opens in a new tab)

  6. Real-time mri in two orthogonal slices for therapy monitoring and interventional guidance

    … This work introduces a T2-weighted SSFP-Echo sequence, Ortho-SSFP-Echo, designed to acquire two orthogonal slices simultaneously by interchanging the slice selection and phase encoding directions between the slices. Since SSFP-Echo sequences are inherently prone to motion artifacts, …

    freiburg-diss Repository record for Real-time mri in two orthogonal slices for therapy monitoring and interventional guidance (opens in a new tab)

  7. Kardiovaskuläre MRT bei 1.5 und 3.0 Tesla unter Verwendung von dynamischen SSFP- und statischen "Black-Blood"-Sequenzen, mit und ohne den Einsatz paralleler Bildgebungstechniken

    … zu überwinden. Bei 20 Probanden wurden Cine-SSFP- und „Black-Blood“-FSE-Sequenzen akquiriert mit der Fragestellung der generellen Durchführbarkeit der kardialen MRT bei 3.0 T, der Anwendbarkeit der pMRT bei 1.5 T und 3.0 T und der bestehenden Unterschiede zwischen beiden Feldstärken und …

    fu-berlin Repository record for Kardiovaskuläre MRT bei 1.5 und 3.0 Tesla unter Verwendung von dynamischen SSFP- und statischen "Black-Blood"-Sequenzen, mit und ohne den Einsatz paralleler Bildgebungstechniken (opens in a new tab)

  8. Neue Steady-State-Techniken in der Magnetresonanztomographie

    Die bSSFP-Sequenz kombiniert kurze Akquisitionszeiten mit einem hohen Signal-zu-Rausch-Verhältnis, was sie zu einer vielversprechenden Bildgebungsmethode macht. Im klinischen Alltag ist diese Technik jedoch bisher - abgesehen von vereinzelten Anwendungen - kaum etabliert. Die Hauptgründe hierfür …

    wurz-thes Repository record for Neue Steady-State-Techniken in der Magnetresonanztomographie (opens in a new tab)

  9. Zvýraznění kontrastu pro rozlišení tkání a detekci kontrastních nanočástic metodami magnetickorezonančního zobrazování

    … obsahuje pulsní sekvence spinové echo, FLASH, SSFP-Echo, TrueFISP, Dual - echo SSFP, Dual - echo GRE a FISP. Program umožňuje výpočet parametrů pulsní sekvence (opakovací čas, echo čas, sklápěcí úhel), kde nastává maximum kontrastu a vykreslení grafu průběhu kontrastu v závislosti na zvoleném …

    brno-tech Repository record for Zvýraznění kontrastu pro rozlišení tkání a detekci kontrastních nanočástic metodami magnetickorezonančního zobrazování (opens in a new tab)

  10. Methoden der 23Na-NMR-Bildgebung zur Diagnose am ischämischen und infarzierten Herzen

    … bei freier Präzession im stationären Zustand (SSFP) sowohl in numerischen Simulationen als auch experimentell untersucht.

    wurz-thes Repository record for Methoden der 23Na-NMR-Bildgebung zur Diagnose am ischämischen und infarzierten Herzen (opens in a new tab)

  11. Magnetic Resonance Imaging of the Heart and Vasculature at 3 Tesla: Novel Strategies for the Diagnosis and Risk Stratification of Cardiovascular Disease

    … measurements using steady-state free precession (SSFP) cardiac magnetic resonance; (2) to explore the impact of 3T parallel imaging techniques on the assessment and reproducibility of black-blood aortic atherosclerosis imaging; and (3) to evaluate the feasibility of coronary sinus flow imaging by …

    utswmed Repository record for Magnetic Resonance Imaging of the Heart and Vasculature at 3 Tesla: Novel Strategies for the Diagnosis and Risk Stratification of Cardiovascular Disease (opens in a new tab)

  12. Novel Chemically Selective Rapid Magnetic Resonance Imaging Techniques and the Clinical Applications

    … balanced steady-state free precession (WS b-SSFP) pulse sequences is proposed and theoretically and experimentally compared with traditional methods such as a water-suppressed T1-weighted turbo spin-echo (TSE) sequence. WS b-SSFP is shown to offer significantly improved image quality (higher …

    utswmed Repository record for Novel Chemically Selective Rapid Magnetic Resonance Imaging Techniques and the Clinical Applications (opens in a new tab)

  13. Longitudinal evaluation of aortic hemodynamics in patients with aortic valve pathology using four-dimensional flow cardiovascular magnetic resonance imaging

    … mass were assessed using ECG-gated breath-hold SSFP cine imaging. Aortic dimensions were measured using non-contrast magnetic resonance angiography in FU and axial SSFP imaging of the thorax in P. Standard cardiac MRI analysis was performed using cvi42. Thoracic aorta 4D flow MRI using ECG …

    fu-berlin Repository record for Longitudinal evaluation of aortic hemodynamics in patients with aortic valve pathology using four-dimensional flow cardiovascular magnetic resonance imaging (opens in a new tab)

  14. Effects of Sexual Guilt on the Sexual Attitudes and Sexual Behavior of Family Physicians

    … the Sexuality Survey of Family Practitioners (SSFP) and the Bentler Heterosexual Behavior Assessment Scale (BHBAS) (Bentler, 1968). Those subjects who scored 52 or below on the MFCGS comprised the Low Sex Guilt (LSG) group, while those who scored 53 or above were designated the High Sex Guilt …

    unm Repository record for Effects of Sexual Guilt on the Sexual Attitudes and Sexual Behavior of Family Physicians (opens in a new tab)

  15. Bildgebende Diagnostik einer Doxorubicin-induzierten Myokarditis mittels kontrastmittelgestützter 19F-Magnetresonanztomographie im Tiermodell

    … gefolgt von einer 19F-3D-UTE-SSFP-Sequenz und einer 1H-T2W-3D-TSE-Sequenz und erneut eine 19F-3D-UTE-SSFP-Sequenz durchgeführt. Die Rekonstruktion der 1H- und 19F-Sequenzen erfolgte mit dem für diese Arbeit entwickelten Programm Liver 3.0. Bei jedem Tier wurde das …

    fu-berlin Repository record for Bildgebende Diagnostik einer Doxorubicin-induzierten Myokarditis mittels kontrastmittelgestützter 19F-Magnetresonanztomographie im Tiermodell (opens in a new tab)

  16. Σύγχρονες τεχνικές μαγνητικής τομογραφίας καρδιάς στη διερεύνηση των μυοκαρδιοπαθειών

    … οι ακολουθίες μετάβασης σταθερής κατάστασης (SSFP), ανάκτησης αναστροφής (STIR), η καθυστερημένη ενίσχυση (LGE), η χαρτογράφηση του Τ1και του Τ2, η απόσβεση Τ2 (Τ2*) και η μέτρηση της τάσεως παρουσιάζουν υψηλή χωρική και χρονική διακριτική ικανότητα, αυξημένη ευαισθησία και ειδικότητα και …

    athens Repository record for Σύγχρονες τεχνικές μαγνητικής τομογραφίας καρδιάς στη διερεύνηση των μυοκαρδιοπαθειών (opens in a new tab)

  17. Registration of 3D Cine MRI to 4D Flow MRI via Localization

    … scan (short axis 3D (multiple 2D slices) cine SSFP) through registration. However, since image registration is a non-linear optimization problem, the registration is slow and may not be accurate (e.g. the left ventricle can be incorrectly aligned to the right ventricle). To improve the …

    calgary Repository record for Registration of 3D Cine MRI to 4D Flow MRI via Localization (opens in a new tab)

  18. Magnetic Resonance Imaging in Paediatric Coronary Vasculopathy

    … steady-state-free-precession [3D SSFP) imaging sequence for coronary artery lumen imaging was optimised for its use in children. Patient based studies were performed to show the clinical potential for this approach. Furthermore, contrast-enhanced inversion-prepared coronary vessel …

    kings Repository record for Magnetic Resonance Imaging in Paediatric Coronary Vasculopathy (opens in a new tab) Download PDF for Magnetic Resonance Imaging in Paediatric Coronary Vasculopathy (opens in a new tab)