Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 421 for “"STROKE VOLUME"”.
-
Admittance derived stroke volume for determination of hemodynamic stability during atrial and ventricular arrhythmias
… arrhythmia is identified by decreased forward stroke volume (SV) and resultant low blood pressure (BP). It would be ideal to have beat-by-beat SV available to the ICD to assist in the delivery of therapies. A system that utilizes the right ventricular (RV) shocking lead of an ICD to measure the …
-
Accuracy of impedance cardiography for the measurement of stroke volume and hemodynamic factors affecting this method
This document only includes an excerpt of the corresponding thesis or dissertation. To request a digital scan of the full text, please contact the Ruth Lilly Medical Library's Interlibrary Loan Department (rlmlill@iu.edu).
-
Spectral analysis of arterial blood pressure and stroke volume variability: the role of Calcium channel blockers and sensitizers
… first one considered the effects of the blood volume changes, during blood donation, on the heart rate variability (HRV) measured, non-invasively, form electrocardiographic (ECG) and photoplethysmographic (PPG) signals. Our results showed that, during blood donation, there were no significant …
-
A novel, non-invasive, optical device for the measurement of total haemoglobin and stroke volume, and for the identification of fluid responsiveness – initial clinical evaluation
… universally accepted into clinical practice. Stroke volume is the amount of blood ejected from the heart at each heartbeat, and is one of the determinants of cardiac output (which is also responsible for ensuring adequate tissue oxygen delivery). It varies across many clinical states, …
-
ΜΕΤΡΗΣΗ ΦΥΣΙΟΛΟΓΙΚΩΝ ΤΙΜΩΝ ΚΑΡΔΙΑΚΗΣ ΠΑΡΟΧΗΣ ΜΕ ΤΗ ΜΕΘΟΔΟ ΤΗΣ ΘΩΡΑΚΙΚΗΣ ΗΛΕΚΤΡΙΚΗΣ ΒΙΟΑΝΤΙΣΤΑΣΗΣ
… IN SUPINE AND STANDING POSITION, RESPECTIVELY. STROKE VOLUME WAS 83.2 +- 13.97 AND 63.76 +- 10.51 ML PERBEAT, RESPECTIVELY. CARDIAC INDEX (L/MIN /M2) WAS 3.37 +- 0.49 (SUPINE) AND2.98 +- 0.44 (STANDING). STROKE VOLUME INDEX WAS 46.98 +- 7.49 AND 36.05 +- ML PER BEAT/M2, RESPECTIVELY. A DECLINE …
-
Respiratory responses of the striped mullet, Mugil cephalus, to three environmental stresses
… in the respiratory parameters of ventilation volume, opercular rate, opercular stroke volume, percentage utilization of oxygen, and metabolic rate were measured in response to the stress environments of hypersalinity, hypoxia, and a sublethal level of petrochemical effluent. These measurements …
-
Magnetic resonance imaging of the right ventricle in human pulmonary hypertension
… reasons for right and left ventricular stroke volume impairment during exercise in PH patients. ∆ RV stroke volume appeared limited by diminished contractile reserve as ∆ RVEF was lower in PH patients (27%) compared to controls (38%) and ∆ RVEF correlated with ∆ RV stroke volume (r = …
-
Impedance cardiography in the elderly
… to the elderly, may improve the validity of stroke volume estimation. Cyclical, small changes in thoracic impedance do occur and are related to the cardiac cycle but from the evidence available it is not clear whether the change is solely related to left ventricular stroke volume or a …
-
Control of the function of the heart in teleost fish
… the activity of the isolated trout heart: rate, stroke volume, cardiac output, stroke work, and heart work per minute. Heart function curves were constructed showing the relationship between each of these variables and the input pressure at two levels of epinephrine, 0.1 ug/ml and 0.01 ug/ml, and …
-
Enabling Wearable Hemodynamic Monitoring Using Multimodal Cardiomechanical Sensing Systems
Hemodynamic parameters such as blood pressure and stroke volume are instrumental to understanding the pathogenesis of cardiovascular disease. Unfortunately, the monitoring of these hemodynamic parameters is still limited to in-clinic measurements and cumbersome hardware precludes convenient, …
-
The effects of a six week sea level exposure on the cardiac output of high altitude Quechua natives
… protocol. Measurements of cardiac output, stroke volume, and heart rate, were taken at rest and then workloads corresponding to 40%, 60%, (and in the case of the ventriculograms) 90% of maximal oxygen consumption. The results were analyzed using repeated measures ANOVA to determine if …
-
The Effect of Temperature Extremes on Cardiorespiratory Function in the Grass Shrimp Palaemonetes pugio: Oxygen Limited Thermal Tolerance
… video microscopy method to measure ventilatory volumes in small aquatic crustaceans. Temperature had a significant effect on all ventilatory parameters measured including scaphognathite stroke volume, ventilatory rate, and ventilation volume. Hypometabolism and hypoventilation were observed in …
-
Hemodynamic Responses to Isometric Contractions of the Finger Flexor and Leg Extensor Muscle Groups in Men 18-30 and 50-70 Years of Age
… which cardiovascular variables(s), heart rate, stroke volume, cardiac output, total peripheral resistance, systolic blood pressure, diastolic blood pressure, pulse pressure, and mean arterial pressure demonstrated significantly different responses to isometric exercise between the two age …
-
The cardiovascular consequences of burn injury
… including falls in the cardiac output, the stroke volume of the heart and the peripheral vascular conductance, but only small changes in blood pressure and heart rate. It has been suggested that the loss of plasma volume due to leakage from damaged or dilated capillaries, leads to a decrease …
-
Endurance Training In Elderly Males
… oxygen ((a-v)O2) difference, heart rate and stroke volume and a lower vascular conductance. The capacity to generate short-term power was also about 30% lower in the elderly.</p> <p>After training, peak VO2 (1/min) increased from 1.599 ± 0.073 to 2.212 ± 0.093 (38Z) in the elderly and 2.536 ± …
Page 1 of 22