Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 18 of 18 for “"SWEI"”.

  1. Implementation and Algorithm Development of 3D ARFI and SWEI Imaging for in vivo Detection of Prostate Cancer

    … imaging and shear wave elasticity imaging (SWEI) to visualize cancer in the prostate, however multiple challenges with both methods have been identified.</p><p>The aim of this thesis is to contribute to both the technical development and clinical applications of ARFI and SWEI imaging using …

    duke Repository record for Implementation and Algorithm Development of 3D ARFI and SWEI Imaging for in vivo Detection of Prostate Cancer (opens in a new tab)

  2. Mapping Myocardial Elasticity with Intracardiac Acoustic Radiation Force Impulse Methods

    … imaging and shear wave elasticity imaging (SWEI) are viable tools for quantification of myocardial elasticity, both temporally and spatially. Multiple track location SWEI (MTL-SWEI) is used to show that, in healthy in vivo porcine ventricles, shear wave speeds follow the elasticity changes …

    duke Repository record for Mapping Myocardial Elasticity with Intracardiac Acoustic Radiation Force Impulse Methods (opens in a new tab)

  3. Ultrasonic Rotational 3D Shear Wave Elasticity Imaging of In Vivo Skeletal Muscle

    <p>Ultrasound shear wave elasticity imaging (SWEI) has the potential to fill a critical clinical gap by providing biomarkers of muscle health that are noninvasive, inexpensive, and quantitative, which could augment or replace the current limited clinical options. However, skeletal muscle does not …

    duke Repository record for Ultrasonic Rotational 3D Shear Wave Elasticity Imaging of In Vivo Skeletal Muscle (opens in a new tab)

  4. Improving Prostate Cancer Detection using Multiparametric Ultrasound

    … (ARFI) imaging, shear wave elasticity imaging (SWEI), quantitative ultrasound’s (QUS) midband fit parameter (MF), and multiparametric ultrasound (mpUS), for PCa identification and targeting during biopsy. The goals of this thesis are to (1) establish a shear wave speed (SWS) threshold for …

    duke Repository record for Improving Prostate Cancer Detection using Multiparametric Ultrasound (opens in a new tab)

  5. Assessment of Cardiac Function by Acoustic Radiation Force (ARF) Based Methods of Ultrasound Elastography

    … (ARFI) and shear wave elasticity imaging (SWEI) ultrasound elastography techniques were studied. These are qualitative and quantitative measures of stiffness, respectively. While the focus of the studies was more on SWEI due to its quantitative nature, ARFI measurements of cardiac function …

    duke Repository record for Assessment of Cardiac Function by Acoustic Radiation Force (ARF) Based Methods of Ultrasound Elastography (opens in a new tab)

  6. Characterizing Shear and Tensile Anisotropy in Skeletal Muscle using Ultrasonic Rotational 3D Shear Wave Elastography

    <p>Shear wave elastography imaging (SWEI) of skeletal muscle is of great interest to the medical community, as there is a large need for a non-invasive, quantitative biomarker of muscle health that relates to muscle function. SWEI measures mechanical properties by generating quantitative images of …

    duke Repository record for Characterizing Shear and Tensile Anisotropy in Skeletal Muscle using Ultrasonic Rotational 3D Shear Wave Elastography (opens in a new tab)

  7. A 3-D Multiparametric Ultrasound Elasticity Imaging System for Targeted Prostate Biopsy Guidance

    … imaging and shear wave elasticity imaging (SWEI), to develop and optimize a robust 3-D elasticity imaging system for ultrasound-guided prostate biopsies and to quantify its performance in prostate cancer detection. Towards that goal, in this dissertation advanced techniques for generating …

    duke Repository record for A 3-D Multiparametric Ultrasound Elasticity Imaging System for Targeted Prostate Biopsy Guidance (opens in a new tab)

  8. Imaging and Characterizing Human Prostates Using Acoustic Radiation Force

    … based upon shear wave elasticity imaging (SWEI). Co-registered ARFI and SWEI datasets were acquired in excised prostate specimens to reconstruct the shear moduli of prostatic tissues. The results demonstrated that variations in ARFI displacement amplitudes were inversely related to the …

    duke Repository record for Imaging and Characterizing Human Prostates Using Acoustic Radiation Force (opens in a new tab)

  9. Computational Modeling of Ultrasound Impulse Induced Wave Velocities in the Fibrotic Atria

    … the potential of shear wave elasticity imaging (SWEI) in evaluating local fibrosis. SWEI has been used previously in the clinic and in real-time during ablation procedures to perform lesion evaluation. The study uses finite element modeling (FEM) to simulate ultrasound-induced mechanical wave …

    duke Repository record for Computational Modeling of Ultrasound Impulse Induced Wave Velocities in the Fibrotic Atria (opens in a new tab)

  10. Multi-Dimensional Ultrasonic Shear Wave Reconstructions: Improving the Accuracy of Viscoelastic Parameter Estimation

    … work of shear wave elasticity imaging (SWEI) methods to improve estimates of viscoelastic parameters in the context of liver screening for tumors, with the goals of (1) using multi-dimensional directional filtering and shear wave reconstruction to reduce reflection artifacts, (2) …

    duke Repository record for Multi-Dimensional Ultrasonic Shear Wave Reconstructions: Improving the Accuracy of Viscoelastic Parameter Estimation (opens in a new tab)

  11. Safety Considerations and Clinical Benefit Analysis for the Use of Elevated Acoustic Output in Diagnostic Ultrasound Imaging

    … harmonic shear wave elasticity imaging (SWEI). Since ultrasound SWEI sequences consist of a long push pulse and a short tracking pulse, it remains unclear which one of the two pulses is impacted more by the body wall and benefits more from elevated MI. In Chapter 3, an opposing window …

    duke Repository record for Safety Considerations and Clinical Benefit Analysis for the Use of Elevated Acoustic Output in Diagnostic Ultrasound Imaging (opens in a new tab)

  12. Quantifying the Impact of Imaging with Elevated Acoustic Output in Diagnostic Ultrasound

    … excitation of shear wave elasticity imaging (SWEI). High MI B-mode harmonic imaging resulted in modest increases in the contrast-to-noise ratio of hypoechoic hepatic vessels. Difficult-to-image patients who suffer from poor ultrasound image quality demonstrated larger improvement than …

    duke Repository record for Quantifying the Impact of Imaging with Elevated Acoustic Output in Diagnostic Ultrasound (opens in a new tab)

  13. Transthoracic Measurement of Dynamic Myocardial Stiffness using Acoustic Radiation Force-Based Ultrasound Methods

    … imaging and shear wave elasticity imaging (SWEI), provide the means to measure mechanical properties of soft tissues using ultrasound. They operate on the principle that ultrasound can be used to remotely generate as well as track micron-level vibrations in the body and thus derive …

    duke Repository record for Transthoracic Measurement of Dynamic Myocardial Stiffness using Acoustic Radiation Force-Based Ultrasound Methods (opens in a new tab)

  14. Assessment of Mechanical and Hemodynamic Vascular Properties using Radiation-Force Driven Methods

    … a result, novel imaging approaches (SAD-SWEI, SAD-GATED) were developed</p><p>for combining spectral Doppler methods with existing ARF-based imaging</p><p>techniques to allow for the combined assessment of cross-luminal velocity profiles,</p><p>wall-shear rate (WSR), ARFI displacement and …

    duke Repository record for Assessment of Mechanical and Hemodynamic Vascular Properties using Radiation-Force Driven Methods (opens in a new tab)

  15. Volumetric Acoustic Radiation Force Impulse Imaging Using Intracardiac Echocardiography

    … scanner was programmed with sequences to perform SWEI imaging on the Soundstar 8F linear array ICE catheter and to perform volumetric ARFI scans using the AcuNav V helicoid array catheter. These sequences were used respectively to characterize the stiffness contrast in ablated human atrial tissue …

    duke Repository record for Volumetric Acoustic Radiation Force Impulse Imaging Using Intracardiac Echocardiography (opens in a new tab)

  16. Temporal Processing of High Frame Rate Ultrasound Images

    … in ultrasound, such as Doppler, ARFI, and SWEI, require transmit-receive sequences different than used in standard B mode or volumetric imaging, requiring a reduction in imaging rate. Using the Duke University Phased Array System, T5, a high frame rate imaging scheme was developed for live …

    duke Repository record for Temporal Processing of High Frame Rate Ultrasound Images (opens in a new tab)

  17. Transthoracic Cardiac Acoustic Radiation Force Impulse Imaging

    … ARFI images and shear wave elasticity imaging (SWEI) movies. Also presented is a rigorous safety analysis, including finite element method (FEM) simulations of tissue heating, hydrophone intensity and mechanical index (MI) measurements, and thermocouple transducer face heating measurements. For …

    duke Repository record for Transthoracic Cardiac Acoustic Radiation Force Impulse Imaging (opens in a new tab)