Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 723 for “"Sample Collection"”.

  1. Autonomous Sample Collection Using Image-Based 3D Reconstructions

    Sample collection is a common task for mobile robots and there are a variety of manipulators available to perform this operation. This thesis presents a novel scoop sample collection system design which is able to both collect and contain a sample using the same hardware. To ease the operator …

    vt Repository record for Autonomous Sample Collection Using Image-Based 3D Reconstructions (opens in a new tab)

  2. Are Concentration-Discharge Relations Influenced by Water Sample Collection Methods?

    … (USGS) equal-width increment (EWI) and point samples (PS) from vertical centroid of flow (VCF) were compared at three river sites, the White River near Fayetteville, Richland Creek at Goshen, and War Eagle Creek near Hindsville. A little over three years of concentration data, which was paired …

    arkansas Repository record for Are Concentration-Discharge Relations Influenced by Water Sample Collection Methods? (opens in a new tab)

  3. The effect of sample collection method on thromboelastography in dogs

    … status of patients; however the effect of sample collection on thromboelastography (TEG) remains unknown. The goal of this thesis was to review the preanalytical and patient variables that affect TEG and to determine the effect of sample collection method on TEG. Furthermore, the role of …

    msu Repository record for The effect of sample collection method on thromboelastography in dogs (opens in a new tab)

  4. Improving Sample Collection Of Trace Particles Of Mock Explosive On Nano Coated Sensor

    … of the challenges is bringing explosive vapor samples from the environment to the sensor element. Such collection of a selective and sufficient amount of air sample will enable the device detect the explosive at lower concentration. This can be done by adsorption of the explosive vapor on a …

    mississippi Repository record for Improving Sample Collection Of Trace Particles Of Mock Explosive On Nano Coated Sensor (opens in a new tab)

  5. Sample Collection and DNA Extraction Methods for Environmental DNA Metabarcoding in Headwater Streams

    DNA is found to be free and ubiquitous in the environment where it is no longer associated with the source organism, and is also known as environmental-DNA (eDNA). Methods optimized for specific environments may be able supplement insight to local taxa richness. With the advent of high throughput …

    eku Repository record for Sample Collection and DNA Extraction Methods for Environmental DNA Metabarcoding in Headwater Streams (opens in a new tab)

  6. Home-based sample collection to increase chlamydia retesting and detect reinfections following treatment

    Chlamydia trachomatis is the most common notifiable sexually transmissible infection in Australia with the highest prevalence in young people and men who have sex with men (MSM). Repeat detection of chlamydia is common following treatment, mainly as a result of reinfection. Retesting at three …

    unsw Repository record for Home-based sample collection to increase chlamydia retesting and detect reinfections following treatment (opens in a new tab)

  7. Optimizing sample collection and data interpretation for effective wastewater-based epidemiology in combined sewer systems

    … in wastewater treatment plant (WWTP) influent samples collected during dry versus wet weather conditions; (2) to assess accuracy of grab versus 24-hour composite samples collected under variable flow conditions; and (3) to examine changes in wastewater influent composition associated with …

    wvu Repository record for Optimizing sample collection and data interpretation for effective wastewater-based epidemiology in combined sewer systems (opens in a new tab)

  8. A Sample-Collection Device for SEM Imaging and Analysis of Coke Deposits from Lubricant Thermal Degradation

    … adverse operational effects within engines. A collection device designed to allow coke to form on its surface was inserted inside of a test section to further study the physical characteristics of coke. The device was made from 0.003-inch-thick stainless steel 304 and went through several …

    tamu Repository record for A Sample-Collection Device for SEM Imaging and Analysis of Coke Deposits from Lubricant Thermal Degradation (opens in a new tab)

  9. Influence of athletes hyperhydration on sample collection procedure in terms of plasma and urine pharmacokinetics of representative prohibited substances

    … and tampering or any attempt to tamper collected samples are all considered as doping offences.Excessive fluid intake, i.e., hyperhydration is not prohibited as a practice according to the World Anti-Doping Agency`s (WADA) current regulations. However, hyperhydration may be adopted by athletes as …

    greece Repository record for Influence of athletes hyperhydration on sample collection procedure in terms of plasma and urine pharmacokinetics of representative prohibited substances (opens in a new tab)

  10. Soil 14CO2 Source Apportionment for Biodegradation in Contaminated Soils in Permafrost Climates: A Novel Technique for Rapid Sample Collection by Barium Carbonate Precipitation

    … to test a new sampling technique to facilitate sample shipment from remote sites, which traps soil CO2 in small sealed exetainers as a solid barium carbonate. Data obtained from established radiocarbon sampling procedures and this new novel approach were shown to be comparable and reproducible. …

    ottawa-retro Repository record for Soil 14CO2 Source Apportionment for Biodegradation in Contaminated Soils in Permafrost Climates: A Novel Technique for Rapid Sample Collection by Barium Carbonate Precipitation (opens in a new tab)

  11. Stabilization and variability of field parameters and polycyclic aromatic hydrocarbons in groundwater at former manufactured gas plant (FMGP) sites using low-flow sample collection methods

    … cell during purge events, while groundwater samples were collected throughout the purge event for polycyclic aromatic hydrocarbons (PAH) analyses at two FMGP sites. Low-flow sample collection methods were used with pump rates between 100 and 1000 mL/min. Dedicated submersible pumps were used …

    iastate Repository record for Stabilization and variability of field parameters and polycyclic aromatic hydrocarbons in groundwater at former manufactured gas plant (FMGP) sites using low-flow sample collection methods (opens in a new tab)

  12. Non-invasive skin sampling: optimization of sample collection and extraction; Enhancing cytokine recovery by the modification of extraction solvents and the use of alternative sampling methods

    … at levels too low to be detected in skin surface samples. The aim of this master’s thesis was to refine a non-invasive skin sampling technique, enhancing cytokine recovery by optimizing both the sample collection method and the cytokine extraction solvent. Improved cytokine recovery leads to more …

    chalmers Repository record for Non-invasive skin sampling: optimization of sample collection and extraction; Enhancing cytokine recovery by the modification of extraction solvents and the use of alternative sampling methods (opens in a new tab)

  13. UAV-Assisted Water Quality Monitoring

    … the management of water resources requires the collection of water samples for physical, chemical, and biological analysis. It is essential to reduce the cost of water quality monitoring by minimizing the number of grab samples and to reduce the sampling time by rapidly accessing the sampling …

    clemson Repository record for UAV-Assisted Water Quality Monitoring (opens in a new tab)

  14. Impact of Personal, Familial, and Socioeconomic Factors On The Return of Remotely Collected Samples For Genetic Testing

    … the genetic counseling (GC) appointment, and in sample types used for genetic testing, specifically with use of telemedicine and remotely collected saliva kits. Previous studies have described lack of patient follow-through in returning these kits. Though the understanding of barriers to medical …

    uthsc Repository record for Impact of Personal, Familial, and Socioeconomic Factors On The Return of Remotely Collected Samples For Genetic Testing (opens in a new tab)

  15. Development of a sampling system for the collection of exhaled breath condensates and its subsequent analysis using 2-dimensional gas chromatography

    … it is not used as extensively as blood or urine samples for medical diagnostics. Some of the major reasons for this include the lack of a standard method of sample collection, control of variability, reliable detection at trace level and quantification. Breath analysis has recently attracted …

    gatech Repository record for Development of a sampling system for the collection of exhaled breath condensates and its subsequent analysis using 2-dimensional gas chromatography (opens in a new tab)

  16. AUTONOMOUS HYBRID AERIAL-TERRESTRIAL TRANSPORT AND RETRIEVAL FOR IN-SITU COLLECTION

    … of both aerial and terrestrial motion, for sample search and retrieval, enabling autonomy through the customization of existing software for new applications. This research addresses challenges related to autonomous detection of, and navigation with respect to, fiducial markers - in both the …

    maryland Repository record for AUTONOMOUS HYBRID AERIAL-TERRESTRIAL TRANSPORT AND RETRIEVAL FOR IN-SITU COLLECTION (opens in a new tab)

  17. Exploring Raptor Migration Using Stable Isotope Analysis: The Northern Goshawk in Western North America

    … had two major field components: breeding season sample collection and migration sample collection. I conducted breeding season work during the summer of 2002 and 2003 at goshawk nests throughout the Pacific Northwest; migration work occurred during the fall of 2002 and 2003 at the Idaho Bird …

    boise Repository record for Exploring Raptor Migration Using Stable Isotope Analysis: The Northern Goshawk in Western North America (opens in a new tab)

  18. Tongue Swab User Acceptance for Tuberculosis Diagnosis: Characterizing the Facilitators and Barriers of Tongue Swab Use During the Era of COVID-19

    … Tongue swabbing is an alternative diagnostic sample collection approach that was designed to mitigate this risk. This study assessed risk perceptions among healthcare workers (HCWs) using tongue swabs for TB diagnosis in South Africa during a respiratory virus pandemic. We characterized the …

    washington Repository record for Tongue Swab User Acceptance for Tuberculosis Diagnosis: Characterizing the Facilitators and Barriers of Tongue Swab Use During the Era of COVID-19 (opens in a new tab)

  19. Characterization of the impacts of water line cleaning and disinfection on swine wean-to-finish water line ecology

    … and disinfectant, peracetic acid. One central sample population was utilized to analyze several components of baseline and post-water line treatment swine water line ecology parameters to meet each of the chapter’s study objectives. This work is highly relevant as it occurred in-situ, to …

    iastate Repository record for Characterization of the impacts of water line cleaning and disinfection on swine wean-to-finish water line ecology (opens in a new tab)

  20. Sample Adequacy Controls for Infectious Disease Diagnosis by Oral Swabbing

    … quality assurance strategies to assure proper sample collection. Two sample adequacy controls (SAC) that detect substances that are differentially present in properly versus improperly collected samples were assessed. One control detected oral microbial flora (Streptococcus species DNA) and the …

    washington Repository record for Sample Adequacy Controls for Infectious Disease Diagnosis by Oral Swabbing (opens in a new tab)

Page 1 of 37