Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 28 for “"Sample Damage"”.

  1. Establishing the extent of sample damage and safe limits of laser exposure during live cell analysis with raman spectroscopy

    For a technique to be applied to any system or sample with a need for robust reproducibility, it must undergo rigorous testing and have well defined protocols and procedures. Raman spectroscopy still currently suffers from instrument and user variability, as well as not having enough well defined, …

    strathclyde Repository record for Establishing the extent of sample damage and safe limits of laser exposure during live cell analysis with raman spectroscopy (opens in a new tab)

  2. Stiffness Degradation and Sample Damage of the Lea Park Formation Shale for A Slow-Moving Landslide in South-Central Saskatchewan

    … and are used to gather relatively undisturbed samples of the shale at depth. The stiffness of the recovered samples was then evaluated using both small strain and engineering strain increments. Several in-situ testing methods including surficial and downhole geophysics as well as barometric …

    sask Repository record for Stiffness Degradation and Sample Damage of the Lea Park Formation Shale for A Slow-Moving Landslide in South-Central Saskatchewan (opens in a new tab)

  3. Improving Biospecimen Imaging in Liquid Phase Electron Microscopy

    … the progress made in LPEM and the study of biosamples. The introduction provides a comprehensive overview of the challenges encountered in investigating molecular processes and traces the historical evolution of microscopy, leading up to the development of transmission electron microscopy …

    waterloo Repository record for Improving Biospecimen Imaging in Liquid Phase Electron Microscopy (opens in a new tab)

  4. Quantitative Prediction of Tip-Sample Repulsive Forces and Sample Deformation in Tapping-Mode Frequency and Force Modulation Atomic Force Microscopy

    The ability to predict sample deformation and the resultant interaction forces is a vital component to preventing sample damage and acquiring accurate height traces in atomic force microscopy (AFM). By using the recently developed frequency and force modulation (FFM) control scheme, a prediction …

    maryland Repository record for Quantitative Prediction of Tip-Sample Repulsive Forces and Sample Deformation in Tapping-Mode Frequency and Force Modulation Atomic Force Microscopy (opens in a new tab)

  5. Plasmonic enhanced pyroelectrics for microfluidic manipulation

    … objects, and reduces the risk of photoinduced sample damage by reducing excitation power required for trapping. Plasmon resonance introduces an unavoidable heating effect which hinders stable trapping in microfluidic environments as a result of phenomena such as convection. In this work, the …

    glasgow Download PDF for Plasmonic enhanced pyroelectrics for microfluidic manipulation (opens in a new tab)

  6. Characterization Of Island-In-The-Sea Bi-Component Nylon/Polyethylene Terephthalate Fibers Using Atomic Force Acoustic Microscopy

    … material properties at the nanoscale without sample damage. The following project has proven that the Atomic Force Acoustic Microscopy technique can be used on soft materials such as fibers. The nylon/polyethylene terephthalate (PET) fibers were embedded in epoxy and microtomed in order to …

    cornell Repository record for Characterization Of Island-In-The-Sea Bi-Component Nylon/Polyethylene Terephthalate Fibers Using Atomic Force Acoustic Microscopy (opens in a new tab)

  7. Detector positioning in a field-deployable limited-angle gamma ray emission tomography system

    … in the inspection of internal parameters without sample damage. These methods take advantage of the interactions of matter with the medium to present quantitative and qualitative information about a sample, where a sectional scanning technique that performs a rotation of the sample or the …

    uoit Repository record for Detector positioning in a field-deployable limited-angle gamma ray emission tomography system (opens in a new tab)

  8. Advanced Focused Ion Beam: Preparation Optimization and Damage Mitigation

    … Ion Beam (FIB) is an important analytical and sample modification technique in the field of electron and ion microscopy. It has been widely used in different kinds of applications including semiconductor device failure analysis, material science research, nanoscale 3D tomography, as well as …

    qucosa-diss

  9. Computational particle beam microscopy

    … as helium ions or electrons, is incident on a sample, producing secondary electrons that reflect sample topography and chemical composition information. The generated secondary electrons are then collected by a detector to produce images of the sample surface. One limiting factor of these …

    bu Repository record for Computational particle beam microscopy (opens in a new tab)

  10. Electron ptychographic imaging of polymer and macromolecular ordering

    … low crystallinity, poor contrast and severe beam damage. Therefore, an electron microscopic technique that uses reduced dose and also has higher contrast from light elements is required for the microstructural study.</p> <p>Electron ptychography is an electron efficient imaging mode that offers …

    oxford Repository record for Electron ptychographic imaging of polymer and macromolecular ordering (opens in a new tab)

  11. Improving the Accuracy, Reliability, and Throughput of Nanoindentation Hardness and Modulus

    … in a high-throughput manner without extensive sample preparation and with minimal sample damage after testing. However, this versatility introduces a level of complexity, and due to the various methods for performing nanoindentation tests and collecting data, there are inevitably opportunities …

    tamu Repository record for Improving the Accuracy, Reliability, and Throughput of Nanoindentation Hardness and Modulus (opens in a new tab)

  12. Modeling time-resolved interaction force mode AFM imaging

    … having active and complete control on tip-sample forces, causing sample damage and inaccurate topography measurement. Ideally, an AFM probe should offer high bandwidth to resolve interaction forces, active control capability for small interaction force and stable operation, and sufficient …

    gatech Repository record for Modeling time-resolved interaction force mode AFM imaging (opens in a new tab)

  13. Development Of Laser Spectroscopy For Elemental And Molecular Analysis

    … instrumentation, and lead to minimal or no sample damage. In this dissertation, fundamental studies to improve LIBS analytical performance were performed and its fusion with Raman into one single sensor was explored. On the fundamental side, Thomson scattering was reported for the first time …

    ucf Repository record for Development Of Laser Spectroscopy For Elemental And Molecular Analysis (opens in a new tab)

  14. Microstructural Evolution in Thermally Cycled Large-Area Lead and Lead-Free Solder Joints

    … and Sn/Ag/0.7Cu, sustained the most severe damage as compared to Sn/37Pb, and 2) due to elevated stresses at the solder/substrate interface in a simulated power semiconductor device sample damage was found to be most severe.

    vt Repository record for Microstructural Evolution in Thermally Cycled Large-Area Lead and Lead-Free Solder Joints (opens in a new tab)

  15. Cyclic electron illumination and beam response measurement using < 1 μs multi trigger exposures on the Merlin-Medipix detector

    … observe dynamic microscopic phenomena and reduce sample damage in electron microscopy to enable better understanding of physical phenomena and to allow higher-fidelity microstructure determination for materials science and biological applications. This need is driving advances in time resolved …

    uvic Repository record for Cyclic electron illumination and beam response measurement using < 1 μs multi trigger exposures on the Merlin-Medipix detector (opens in a new tab)

  16. Inelastic Light Scattering in Low Dimensional Semiconductors

    … in the direction of growth. Assessment of sample damage produced by reactive-ion-etching (RIE) was undertaken as a prerequisite to the study of phonons in fabricated nanostructures. Structural damage to the crystal showed up as a relaxation of the crystalline selection rules allowing the …

    glasgow Download PDF for Inelastic Light Scattering in Low Dimensional Semiconductors (opens in a new tab)

  17. Rapid signal modeling via directed acyclic graphs and magnet tip nanofabrication for magnetic resonance force microscopy

    … using MRFM with a gamma-irradiated quartz sample. Our modulated cantilever-enabled readout of magnetization inversion transients (CERMIT) protocol detects the modulated shift in the cantilever frequency arising from the force gradient change when microwaves are applied to the system, …

    cornell Repository record for Rapid signal modeling via directed acyclic graphs and magnet tip nanofabrication for magnetic resonance force microscopy (opens in a new tab)

  18. Mechanics of Interactions and Atomic-Scale Wear of Tips ian Amplitude Modulation Atomic Force Microscopy

    … investigate and discuss the mechanics of the tip-sample interaction in AM-AFM. Starting from existing analytical formulations, we introduce a method for conveniently choosing an appropriate probe and free oscillation amplitude that avoids exceeding a critical contact stress to minimize tip/sample …

    penn Repository record for Mechanics of Interactions and Atomic-Scale Wear of Tips ian Amplitude Modulation Atomic Force Microscopy (opens in a new tab)

  19. Deep Learning Methods for Biological Image Translation and Registration

    … for observation. However, the process of sample labelling is time-consuming and laborious and occasionally subsequent sample damage arises from these labels. In particular cases, fluorescent images are necessities, but labelling experiments are infeasible. Image translation approaches …

    bristol Repository record for Deep Learning Methods for Biological Image Translation and Registration (opens in a new tab) Download PDF for Deep Learning Methods for Biological Image Translation and Registration (opens in a new tab)

  20. Lazerių optinių elementų pažaidos slenksčio prognozavimo tyrimas: spinduliuotės erdvinių ir energinių parametrų įtaka /

    … (below the threshold's limited operating time to damage) beyond which the element is irreparably destroyed. The optical element that has experienced a defect can no longer be used in the optical system, so the entire optical circuit ceases to operate. An international ISO standard methodology has …

    vilnius Repository record for Lazerių optinių elementų pažaidos slenksčio prognozavimo tyrimas: spinduliuotės erdvinių ir energinių parametrų įtaka / (opens in a new tab)

Page 1 of 2