Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 31 for “"Sampled Values"”.

  1. Performance Analysis of Sampled Values-Based Protection in IEC 61850 Process Bus Networks

    … presents a complete test bench for evaluating sampled values-based protection schemes and measures their efficacy under several different operating conditions. It is shown that the novel system operates correctly for the situations it is expected to, with minimal latency compared to traditional …

    vt Repository record for Performance Analysis of Sampled Values-Based Protection in IEC 61850 Process Bus Networks (opens in a new tab)

  2. Implementation of an IEC 61850 Sampled Values Based Line Protection IED with a New Transients-Based Hybrid Protection Algorithm

    … the work done towards implementing an IEC 61850 sampled values based line protection Intelligent Electronics Device (IED) on a desktop computer. This IED is capable of subscribing, decoding and processing the sampled values published by a source to be used in line protection algorithms. The novel …

    manitoba Repository record for Implementation of an IEC 61850 Sampled Values Based Line Protection IED with a New Transients-Based Hybrid Protection Algorithm (opens in a new tab)

  3. Generátor útoků na SCADA protokoly

    … mezi uzly SCADA systému, konkrétně na GOOSE a Sampled Values. Simulovaná zařízení generují komunikaci s využitím knihovny libiec61850, na kterou jsou pak útoky cíleny.

    brno-tech Repository record for Generátor útoků na SCADA protokoly (opens in a new tab)

  4. Generátor útoků na SCADA protokoly

    … mezi uzly SCADA systému, konkrétně na GOOSE a Sampled Values. Simulovaná zařízení generují komunikaci s využitím knihovny libiec61850, na kterou jsou pak útoky cíleny.

    brno-tech Repository record for Generátor útoků na SCADA protokoly (opens in a new tab)

  5. Zhodnocení metod rychlého odkruhování distribučních sítí

    … s medzinárodným štandardom IEC 61850 (GOOSE a Sampled Values) vrátane vplyvu prenosových oneskorení. Vplyv vnorenej výroby na skratové pomery a koordináciu ochrán je posudzovaný ako sekundárny faktor. Výsledkom práce je funkčný návrh logiky ochranného systému, ktorý bol overený v simulačnom …

    brno-tech Repository record for Zhodnocení metod rychlého odkruhování distribučních sítí (opens in a new tab)

  6. Development of Protection Scheme for Non-Conventional Instrument Transformer (NCITs) Based on IEC 61850-9-2

    … digital interface, digital communication and Sampled Values transmission over an Ethernet link called Process Bus. This thesis is mainly based on the development of the non Conventional Instrument Transformers (NCIT), analogue to digital data converter and power system protection.

    vu-aus Download PDF for Development of Protection Scheme for Non-Conventional Instrument Transformer (NCITs) Based on IEC 61850-9-2 (opens in a new tab)

  7. Centralizovaný systém pro měření a řízení v distribučních stanicích

    … a analýzu digitálního systému založeného na sampled values podle normy IEC 61850-9-2 pro monitorování místní inteligentní distribuční sítě VN. Zaměřuje se především na zkoumání, zda přesnost použitých komunikačních protokolů a digitálních měřicích technologií splňuje požadavky na přesnost …

    brno-tech Repository record for Centralizovaný systém pro měření a řízení v distribučních stanicích (opens in a new tab)

  8. On line inductance and resistance calculation for transmission line protection

    … satisfy a single differential equation. Using sampled values of voltage and current this equation is solved numerically for the resistance and inductance of the faulted section. Using fault data from a model transmission line and portion of a high voltage transmission system the calculation …

    unsw Repository record for On line inductance and resistance calculation for transmission line protection (opens in a new tab)

  9. A digital computer program for real-time computation of radar cross section on a dynamic target

    … systems. The input data consists of transmitted values of range, bearing and elevation from the NIKE/AJAX radar digital data buffer and sampled values of automatic gain control voltage and logrithmic amplifier output voltage from the NIKE/AJAX radar. Outputs include values of target range, …

    nps Repository record for A digital computer program for real-time computation of radar cross section on a dynamic target (opens in a new tab)

  10. Passive Rational Fitting of a Passive Network Transfer Function From Its Real Part

    … network transfer function that makes use of sampled values of the transfer function's real part at a set of frequencies over the bandwidth of interest. For passive networks, real-part sufficiency describes the fact that the self and mutual impedance or admittance is uniquely defined in terms …

    uiuc Repository record for Passive Rational Fitting of a Passive Network Transfer Function From Its Real Part (opens in a new tab)

  11. Data Trustworthiness in Synchronized Power System Measurements: Algorithms and Methodologies

    … detection approaches in synchrophasor and sampled values data streams. The analysis extends to Merging Units (MUs) and Phasor Data Concentrators (PDCs), exploring their role not only as data providers but also as active elements for event detection and situational awareness. The proposed …

    cagliari Repository record for Data Trustworthiness in Synchronized Power System Measurements: Algorithms and Methodologies (opens in a new tab)

  12. A universal centralized protection scheme for feeders of AC microgrids using IEC-61869-9 digital instrument transformers

    This thesis underscores the escalating importance of microgrids powered by renewable energy sources and inverters in modern power systems. Despite offering significant environmental and economic advantages, their decentralized and dynamic nature poses unique protection challenges. Traditional …

    uoit Repository record for A universal centralized protection scheme for feeders of AC microgrids using IEC-61869-9 digital instrument transformers (opens in a new tab)

  13. Variable perturbation size maximum power point tracking algorithms for photovoltaic systems

    … control (PCC) and on the use of instantaneous sampled values to calculate the next perturbation can provide faster transient responses and small oscillations around the maximum power point (MPP) than when pulse width modulation (PWM) and averaged control values are used. However, the use of a …

    concordia Download PDF for Variable perturbation size maximum power point tracking algorithms for photovoltaic systems (opens in a new tab)

  14. Deep Parameter Selection For Classic Computer Vision Applications

    … performance for each of a set of discretely sampled values for this parameter and selects the one with the highest predicted performance. Results demonstrate that this per-image prediction and tuning performs better than a single empirically selected setting.

    byu Repository record for Deep Parameter Selection For Classic Computer Vision Applications (opens in a new tab) Download PDF for Deep Parameter Selection For Classic Computer Vision Applications (opens in a new tab)

  15. A method for treating dependencies between variables in a simulation risk analysis model

    … to the target correlation; and (2) the sampled values of the two individual variables must have very accurate means and variances. The research results conclude that the samples from the four chosen distributions that have been generated by the RCM have highly acceptable levels of …

    middlesex Download PDF for A method for treating dependencies between variables in a simulation risk analysis model (opens in a new tab)

  16. Automatic Tuning of Integrated Filters Using Neural Networks

    Component values of integrated filters vary considerably due to· manufacturing tolerances and environmental changes. Thus it is of major importance that the components of an integrated filter be electronically tunable. The method explored in this thesis is the transconductance-C-method. A method of …

    portland-state Repository record for Automatic Tuning of Integrated Filters Using Neural Networks (opens in a new tab)

  17. Algorithms for the synchrophasor measurement in steady-state and dynamic conditions

    … architecture based on process bus and sampled values synchronized with IEEE 1588-2008 is proposed, so that voltage and current signals are acquired by a Merging Unit device, while the PMU signal processing is performed on a IED (Intelligent Electronic Device), in compliance with IEEE …

    cagliari Repository record for Algorithms for the synchrophasor measurement in steady-state and dynamic conditions (opens in a new tab)

  18. Evaluation and Validation of Chatter Detection by Periodic Sampling of Time Domain Milling Signals and Spindle Speed Selection for Stable Cutting Conditions

    … is scanned over a preselected range, and the sampled values of the time domain milling signals are used to calculate a stability metric for each sampling frequency. For stable cutting conditions, the sampled point repeats for each tooth passage, and a local minimum in the stability metric …

    utk-theses Repository record for Evaluation and Validation of Chatter Detection by Periodic Sampling of Time Domain Milling Signals and Spindle Speed Selection for Stable Cutting Conditions (opens in a new tab)

Page 1 of 2