  1. CALIBRATION METHODOLOGY, DIAGNOSTIC PERFORMANCE, AND REDESIGN OF THE CURRENT MONITORS ON THE Z MACHINE AT SANDIA NATIONAL LABORATORIES

    … current diagnostic package for the Z facility at Sandia National Laboratories was the goal of the research in this dissertation. SNL is managed and operated by NTESS under DOE NNSA contract DE-NA0003525 [1] T. C. Wagoner et al., Phy. Rev. Spec. Top. - Acc. and Bms. 11, 100401, (2008). [2] C. E. …

    unm Repository record for CALIBRATION METHODOLOGY, DIAGNOSTIC PERFORMANCE, AND REDESIGN OF THE CURRENT MONITORS ON THE Z MACHINE AT SANDIA NATIONAL LABORATORIES (opens in a new tab)

  2. Characterization of the Neutron Irradiation System for use in the Low-Dose-Rate Irradiation Facility at Sandia National Laboratories

    … placed in a polyethylene shielding for use at Sandia National Laboratories (SNL) Low Dose Rate Irradiation Facility (LDRIF). With a total activity of 0.3 TBq (9 Ci), the source consisted of three recycled 241AmBe sources of different activities that had been combined into a single source. The …

    unm Repository record for Characterization of the Neutron Irradiation System for use in the Low-Dose-Rate Irradiation Facility at Sandia National Laboratories (opens in a new tab)

  3. High Temperature Seismic Monitoring for Enhanced Geothermal Systems - Implementing a Control Feedback Loop to a Prototype Tool by Sandia National Laboratories

    Geothermal energy can make an important contribution to the U.S. energy portfolio. Production areas require seismic monitoring tools to develop and monitor production capability. This paper describes modifications made to a prototypical seismic tool to implement improvements that were identified …

    vt Repository record for High Temperature Seismic Monitoring for Enhanced Geothermal Systems - Implementing a Control Feedback Loop to a Prototype Tool by Sandia National Laboratories (opens in a new tab)

  4. Structural role of nitrogen in phosphorus oxynitride glasses

    … from the collaboration of researchers at Sandia National Laboratories, University of Illinois-Urbana and myself at the University of Missouri-Rolla. This author prepared and measured various chemical and thermal properties for the samples used for the Nuclear Magnetic Resonance (NMR) and …

    must-thes Repository record for Structural role of nitrogen in phosphorus oxynitride glasses (opens in a new tab)

  5. Analysis Of Ternary Chloride Salt Corrosion In High Nickel Alloys

    … above 700°C. To meet these goals, the National Solar Thermal Test Facility at Sandia National Laboratories has considered the use of a ternary molten chloride salt for sensible heat storage systems. While favored for low cost, good heat transfer properties, and stability at high …

    unm Repository record for Analysis Of Ternary Chloride Salt Corrosion In High Nickel Alloys (opens in a new tab)

  6. An exploration of the optical detection of ionizing radiation utilizing modern optics technology

    … measurement) has been demonstrated at Sandia National Laboratories, there are several challenges in correlating images to known dose-fields (quantitative measurement). These challenges include: a low signal to background ratio, interferences due to electronic noise and direct radiation …

    unm Repository record for An exploration of the optical detection of ionizing radiation utilizing modern optics technology (opens in a new tab)

  7. Reactivity estimation and validation for the control of reactor neutronic power.

    … MIT Research Reactor (M1TR-I1) as well as on the Sandia National Laboratories' Annular Core Research Reactor (ACRR). This controller's intended application is for the control of spacecraft nuclear reactors. However, it also has direct application for the control of military, commercial, and …

    nps Repository record for Reactivity estimation and validation for the control of reactor neutronic power. (opens in a new tab)

  8. Vacuum and Optical Designs for an Open-access Trapped Ion Quantum Processor

    … that will house an advanced ion chip trap from Sandia National Laboratories, capable of performing high fidelity operations on up to tens of qubits. The thesis will outline the different design considerations, criteria, and serve to document the final design choices, in addition to optical …

    waterloo Repository record for Vacuum and Optical Designs for an Open-access Trapped Ion Quantum Processor (opens in a new tab)

  9. Cooperative control of autonomous underwater vehicles.

    … a quadratic Newton method and was developed at Sandia National Laboratories. The method has already been successfully applied to several two dimensional problems at Sandia. The original 2D algorithm was converted to 3D and tested for robustness in the presence of sensor error, position error and …

    tamu Repository record for Cooperative control of autonomous underwater vehicles. (opens in a new tab)

  10. A Thermodynamic Study of Binary Real Gas Mixtures Undergoing Normal Shocks

    … shocks. Numerical modeling was performed in the Sandia National Laboratories hydrocode CTH utilizing tabular EOS in the SESAME format. Numerical results were compared to experimental work from the University of New Mexico Shock Tube Laboratory. Latin hypercube samples were used to assess model …

    unm Repository record for A Thermodynamic Study of Binary Real Gas Mixtures Undergoing Normal Shocks (opens in a new tab)

  11. Optimizing Barnes-Hut simulations for many-core super computers using the scalable parallel runtime

    … Runtime (SPR) is a project being developed at Sandia National Laboratories which attempts to address the challenge of efficiently utilizing the power of these new many-core systems. SPR is a combination of the Qthreads Library, Portals, and MPI. In this paper, we investigate optimizing the …

    uiuc Repository record for Optimizing Barnes-Hut simulations for many-core super computers using the scalable parallel runtime (opens in a new tab)

  12. The design, fabrication, installation & evaluation of the Balance Probe Monitor for large centrifuges at a national laboratory facility

    … fabricated, installed, and evaluated at Sandia National Laboratories (SNL) for the 22,600 g kg (50,000 g lb) direct drive electromotor driven large centrifuges. These centrifuges provide a high onset/decay rate g environment. The Balance Probe Monitor is physically located near a …

    texas Repository record for The design, fabrication, installation & evaluation of the Balance Probe Monitor for large centrifuges at a national laboratory facility (opens in a new tab)

  13. Two-color pyrometer measurement of stainless steels due to relativistic electron beam heating in VHV/UHV environments

    … of SS anodes is of particular importance for Sandia National Laboratories. This is because the theory of SS anode outgassing is thought to be a function of temperature increase. To investigate the temperature of the stainless steel anode without the need for an absolute calibration a two-color …

    ttu Repository record for Two-color pyrometer measurement of stainless steels due to relativistic electron beam heating in VHV/UHV environments (opens in a new tab)

  14. Linear stability analysis of Mach 10 nitrogen flow over 7-deg half-angle cones.

    … considered were either generated by STABL at Sandia National Laboratories or with US3D at Baylor University. The LST analysis reproduced the trends of laminar-turbulent transition front moving forward with increasing unit Reynolds number for a sharp nose cone as well as the trend in transition …

    baylor Repository record for Linear stability analysis of Mach 10 nitrogen flow over 7-deg half-angle cones. (opens in a new tab)

  15. Printing Parameter Determination and Characterization of Additively Manufactured Kovar Steel

    … UNS K94610) steel has many applications across Sandia National Laboratories but is best known within academia and industry for its glass-to-metal and glass-to-ceramic hermetic sealing capabilities. Successful printing parameters for a Renishaw AM400 to additively manufacture artifacts from Kovar …

    unm Repository record for Printing Parameter Determination and Characterization of Additively Manufactured Kovar Steel (opens in a new tab)

  16. Qualitative Investigation of Gaseous Hydrodynamic Mixing Model Efficacy and Associated Sensitivity

    … (3D). Numerical simulations utilize the Sandia National Laboratories (SNL) shock hydrodynamic code CTH and other codes including the SNL thermochemical equilibrium code TIGER and the uncertainty qualification (UQ) and sensitivity analysis code DAKOTA. Comparison with experimental results …

    unm Repository record for Qualitative Investigation of Gaseous Hydrodynamic Mixing Model Efficacy and Associated Sensitivity (opens in a new tab)

  17. Intranets

    … Finally, we explore the renowned intranet at Sandia National Laboratories and explain which factors played the most significant role in the success they have achieved with intranet technology at their organization.

    nps Repository record for Intranets (opens in a new tab)

  18. Reaction of Titanium Subhydride with Multiple Passivating Gasses

    Sandia National Laboratories has used substoichiometric titanium hydride as a pyrotechnic fuel for decades. Production of titanium subhydride requires partial dehydriding of titanium hydride powder and subsequent chemical passivation to render the resultant bare titanium surface nonreactive and the …

    unm Repository record for Reaction of Titanium Subhydride with Multiple Passivating Gasses (opens in a new tab)

  19. Simulation and experimental study of the multichanneling rimfire gas switch

    … has been used extensively in accelerators at Sandia National Laboratories. Demands for increased future accelerator performance require improvements to the Rimfire switch. This thesis is both a theoretical and experimental study of this switch. Theoretical study was achieved utilizing an …