Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 114 for “"Sanitary sewer"”

  1. Sanitary Sewer Infiltration/Inflow Reduction Investigation

    … unless the grant applicant showed that each sewer collection system discharging into such treatment facility is not subject to excessive infiltration/inflow.

    marquette Repository record for Sanitary Sewer Infiltration/Inflow Reduction Investigation (opens in a new tab)

  2. Flow Monitoring Limitations in Sanitary Sewer Systems

    … utilized in monitoring wastewater flows in sanitary sewer systems, the reasons for flow monitoring and the limitations of these techniques. Some specific examples of major flow monitoring studies which have been undertaken in the City of Minneapolis and St. Paul, Minnesota will be reviewed …

    marquette Repository record for Flow Monitoring Limitations in Sanitary Sewer Systems (opens in a new tab)

  3. Sanitary sewer evaluation of inflow/infiltration reduction techniques

    … hydraulic issues during rain events, leads to sanitary sewer overflows and can subject the utility to fines from regulatory agencies. As a result, dealing with the inflow portion of I and I is needed. The goal of this thesis is to differentiate inflow and infiltration from baseflow and to …

    fau Repository record for Sanitary sewer evaluation of inflow/infiltration reduction techniques (opens in a new tab)

  4. Design of Sanitary Sewer Systems by Dynamic Programming

    … and procedures currently used in the design of sanitary sewer systems. A review of literature concentrates on procedures for the automated design of sanitary sewer systems. From the literature review, it is concluded that the cost optimisation of a variable layout together with details of sewer …

    mcmaster Repository record for Design of Sanitary Sewer Systems by Dynamic Programming (opens in a new tab)

  5. Kinetics of Hydrogen Sulfide Oxidation in Sanitary Sewer Systems

    … using the techniques commonly employed in sanitary sewer systems to determine the effectiveness of each process. To achieve this objective a laboratory simulation of these chemicals additions was carried out using completely mixed BOD bottles as batchreactors. The BOD reactor was filled …

    uno Repository record for Kinetics of Hydrogen Sulfide Oxidation in Sanitary Sewer Systems (opens in a new tab)

  6. Treatment of sanitary sewer overflow using fixed media bioreactors

    Sanitary sewer overflow (SSO) has characteristics of high flow rate, low and varying pollutant concentrations, and low frequency of events. Fixed media bioreactor (biofilter) is a proven technology used for wastewater treatment in unsewered rural areas. No previous research has been published on …

    ohiolink Repository record for Treatment of sanitary sewer overflow using fixed media bioreactors (opens in a new tab)

  7. Conservation and allocation of slope in gravity sanitary sewer design

    Gravity sanitary sewers are traditionally designed in a relatively direct route from source to destination after considering property boundary/easement constraints and topographic features. A methodology is presented in this research for considering potential energy (as measured by elevation and …

    missouri Repository record for Conservation and allocation of slope in gravity sanitary sewer design (opens in a new tab)

  8. Extraneous flow in a city of Winnipeg separate sanitary sewer system

    The variations in sewage flow rates in a separate sanitary sewer system in the City of Winnipeg were studied during the dry and wet weather conditions. It was found that massive amounts of stormwater or extraneous flow enter the sanitary sewer system during even moderate rainfall. Peak extraneous …

    manitoba Repository record for Extraneous flow in a city of Winnipeg separate sanitary sewer system (opens in a new tab)

  9. Unsteady Modeling of Air Flow and Pollutant Transport in Sanitary Sewer Systems

    Sewer airflow plays a critical role in odor problems because it transports gaseous hydrogen sulfide (H2S) within sewer systems and promotes its emission to the atmosphere through manhole openings. Variations in sewage flow can affect both in-sewer processes and airflow dynamics, which in turn …

    alberta Repository record for Unsteady Modeling of Air Flow and Pollutant Transport in Sanitary Sewer Systems (opens in a new tab)

  10. Hydraulic Performance and Vulnerability on Sanitary Sewer Overflow in Southern Pinellas County, FL

    Rain-induced sanitary sewer overflow due to high infiltration is a significant challenge for many utilities, including Pinellas County utilities. The main aim of this study is to develop a hydraulic model to analyze the performance of the existing sanitary sewer system, especially during intense …

    usf Repository record for Hydraulic Performance and Vulnerability on Sanitary Sewer Overflow in Southern Pinellas County, FL (opens in a new tab)

  11. Sanitary Sewer Overflows in Columbia, South Carolina and their Impact on Mercury and Metal Cycling

    … to human health have been the primary concern of sanitary sewer overflows (SSO); however, SSOs may also be a source of metals, including methylmercury, to local waterways. We hypothesized that SSOs had elevated concentrations of metals compared to nearby reference creeks. Methods. Unfiltered and …

    south-carolina Repository record for Sanitary Sewer Overflows in Columbia, South Carolina and their Impact on Mercury and Metal Cycling (opens in a new tab)

  12. Predicting and Preventing Hydraulic Blow-Outs during High Velocity Jet Cleaning of Sanitary Sewer Lines

    … wastewater collection organizations to clean sewer lines clogged with roots and debris in order to restore or maintain full capacity. In rare cases, the cleaning operation expels air and water from the sewer into private laterals, even out of drains, water closets, and other fixtures in nearby …

    ohiolink Repository record for Predicting and Preventing Hydraulic Blow-Outs during High Velocity Jet Cleaning of Sanitary Sewer Lines (opens in a new tab)

  13. Development and Application of Method to Project Groundwater Infiltration in Sanitary Sewer Systems Affected by Sea Level Rise

    Coastal sanitary sewer networks are increasingly at risk of groundwater infiltration (GWI) into pipes due to sea level rise (SLR). As sea level increases, so does the groundwater table, causing sanitary sewer pipes to become submerged. If structural defects or deterioration, such as cracks, are …

    hawaii Repository record for Development and Application of Method to Project Groundwater Infiltration in Sanitary Sewer Systems Affected by Sea Level Rise (opens in a new tab)

  14. Water Sensitive Urban Design (WSUD) Strategies to Mitigate the Impacts of Intense Rainfall on the Sanitary Sewer Network Performance

    … derived infiltration and inflow (RDII) in aging sewer networks, which leads to Sanitary Sewer Overflows (SSOs). This, in turn, causes various detrimental impacts, both on human health and the environment. This research aims to quantify the benefits of Water Sensitive Urban Design (WSUD) …

    vu-aus Repository record for Water Sensitive Urban Design (WSUD) Strategies to Mitigate the Impacts of Intense Rainfall on the Sanitary Sewer Network Performance (opens in a new tab)

  15. Evaluation of Management Alternatives for Truck Wash Water Generated During Winter Maintenance Activities

    … during the winter months. In locations where sanitary sewer is available, truck wash water is treated with an oil/water separator and discharged directly to the sanitary sewer system. However, at facilities that do not have access to sanitary sewer, truck wash water must be collected and …

    ohiolink Repository record for Evaluation of Management Alternatives for Truck Wash Water Generated During Winter Maintenance Activities (opens in a new tab)