Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 29 for “"Sawbones"”.

  1. Evaluating the ability of a synthetic model knee to mimic varying degrees of anterior cruciate ligament integrity

    … and certified athletic trainers using the Sawbones® M.I.S. Knee model. The second purpose of this study was to determine if a correlation existed between profession and number of correct responses, as well as years of experience and correct responses. The third purpose of this study was to …

    northern-iowa Repository record for Evaluating the ability of a synthetic model knee to mimic varying degrees of anterior cruciate ligament integrity (opens in a new tab)

  2. In Search of An Improved Methodology for Measuring Dental Implant Stability: Combining Experimental Model Analysis (EMA) and Finite Element Analysis (FEA) to Achieve Maximum Reliability

    … models of dental implants of various lengths in Sawbones® of different densities. The theoretical mechanics used to operate the three devices were analyzed to understand their assumptions and limitations. To estimate angular stiffness, we employed implant models of various lengths and widths in …

    washington Repository record for In Search of An Improved Methodology for Measuring Dental Implant Stability: Combining Experimental Model Analysis (EMA) and Finite Element Analysis (FEA) to Achieve Maximum Reliability (opens in a new tab)

  3. The Effect of Central Screw and Post Vault Containment on Reverse Total Shoulder Arthroplasty (RSTA) Baseplate Stability

    … This study examined 36, 12 PCF composite Sawbones® scapulae. The specimens were split equally into 6 study groups, each having different implant configurations with varying baseplate lateralization and central screws or posts. Each specimen was subjected to cyclic shear loading and failure …

    clemson Repository record for The Effect of Central Screw and Post Vault Containment on Reverse Total Shoulder Arthroplasty (RSTA) Baseplate Stability (opens in a new tab)

  4. Morphological and mechanical analysis of the glenoid trabecular bone

    … and initial fixation strength. In this study Sawbones (open cell foam) were used to represent cancellous bone and these enabled the cement to flow within the surrogate bone structure and provide a more suitable morphological model. From this study, it was clear that open cell Sawbones are not …

    whiterose Download PDF for Morphological and mechanical analysis of the glenoid trabecular bone (opens in a new tab)

  5. Comparison of Milling Cutting Forces in Synthetic and Biological Cancellous Bone

    … machinability of bovine bone is compared to a Sawbones #18 polyurethane cancellous bone surrogate. The cutting force between these two materials was compared by measuring the cutting torque at a specified radius. The median cutting force of biological bone under the testing conditions was found …

    gvsu Repository record for Comparison of Milling Cutting Forces in Synthetic and Biological Cancellous Bone (opens in a new tab)

  6. Optimizing the Surgical Treatment of Large Orthopaedic Injuries

    … bending model was constructed by securing sawbones blocks with different orthopaedic fixation device constructs. Stress strain curves derived from a fundamental mechanics model were used to assess the effect of bone density, type of hardware (staple vs intramedullary beam), the use of …

    duke Repository record for Optimizing the Surgical Treatment of Large Orthopaedic Injuries (opens in a new tab)

  7. Space, Self and Place in the Novels of Sinclair Ross

    … House (AMMH), The Well (TW), Whir of Gold (WaG), Sawbones Memorial (SM), The Lamp at Noon and Other Stories (LN), and The Race and Other Stories by Sinclair Ross (TR).</p>

    mcmaster Repository record for Space, Self and Place in the Novels of Sinclair Ross (opens in a new tab)

  8. Development and system integration of a computer-asisted total knee replacement technique

    … the use of an ellipse-fit algorithm on a Sawbones and cadaveric model, and found, upon further verification, that this method could be implemented in computer-assisted systems as it better represents a tibial knee centre than the centre of the tibial eminences currently used in other …

    ubc Repository record for Development and system integration of a computer-asisted total knee replacement technique (opens in a new tab) Download PDF for Development and system integration of a computer-asisted total knee replacement technique (opens in a new tab)

  9. A Biomechanical Evaluation of a Novel Surgical Reconstruction Technique of the Ulnar Collateral Ligament of the Elbow Joint

    … applied a cyclic valgus load to white cortical Sawbones elbow complex models while a 3D electromagnetic motion tracking system recorded the valgus displacement of the UCL reconstructions. The valgus stability, gap formation, and ultimate strength were measured at 50, 100, 200 and 600 cycles or …

    usf Repository record for A Biomechanical Evaluation of a Novel Surgical Reconstruction Technique of the Ulnar Collateral Ligament of the Elbow Joint (opens in a new tab)

  10. Influencia de diferentes protocolos de fresado y densidad ósea en el torque de inserción de implantes dentales

    … en bloques de poliuretano estandarizados (Sawbones Europe AB) de cuatro densidades, de implantes dentales M12 Oxtein (Oxtein, España) con diámetros de 3,5, 4,0, 4,5 y 5mm, y longitudes de 8,5mm, 11,5mm y 14,5mm. Para ello se siguieron cuatro protocolos de fresado, un fresado estándar, otro …

    sevilla Repository record for Influencia de diferentes protocolos de fresado y densidad ósea en el torque de inserción de implantes dentales (opens in a new tab)

  11. Biomechanische Testung zweier Verfahren zur Plattenosteosynthese bei Monteggia-Frakturen

    … wurden insgesamt 24 Kunstknochen (Sawbone 3426, Sawbones® Europa AG in Malmö, Schweden), 12 Knochen pro Gruppe, in einem biomechanischen Testmodell mittels der Materialprüfmaschine Zwick Roell Z020/TH2A (Fa. Zwick GmbH & Co. KG, Ulm) und einer Mikrobewegungsanalyse mit Hilfe des ARAMIS SRX 3D …

    wurz-thes Repository record for Biomechanische Testung zweier Verfahren zur Plattenosteosynthese bei Monteggia-Frakturen (opens in a new tab)

  12. STABILITY OF HAND VERSUS ELECTRICALLY DRIVEN TEMPORARY ANCHORAGE DEVICES

    … 20 PCF with a 1mm cortical plate of 40 PCF (Sawbones USA). TADs were inserted by two methods, hand-driven (n=10) and electric-driven (n=10; at 10 N•cm, 15 RPM) perpendicular to the surface of the bone blocks. All TADs were subjected to a tangential force using an Instron machine until their …

    temple Repository record for STABILITY OF HAND VERSUS ELECTRICALLY DRIVEN TEMPORARY ANCHORAGE DEVICES (opens in a new tab)

  13. Range of Motion and Impingement in Reverse Shoulder Arthroplasty

    … load cells. RSA components were implanted in Sawbones scapula and humerus bone models. The scapula was fixed in the frame of the simulator. Triads of optical tracking markers were attached to the humerus and simulator frame and used to track segment motion. A data analysis technique was …

    queens Repository record for Range of Motion and Impingement in Reverse Shoulder Arthroplasty (opens in a new tab)

  14. Central Fixation Element Type and Size Affect Glenoid Baseplate Micromotion in Reverse Shoulder Arthroplasty

    … baseplates (DePuy Synthes) were implanted into Sawbones™ polyurethane foam blocks (N = 40) and varied in terms of their method of central fixation (screw vs. peg), central length (13.5 vs. 23.5 mm), anterior-posterior peripheral screw type (nonlocking vs. locking), and bone density (10 vs. 25 …

    queens Repository record for Central Fixation Element Type and Size Affect Glenoid Baseplate Micromotion in Reverse Shoulder Arthroplasty (opens in a new tab)

  15. Biological and mechanical investigations into tibial fracture fixation and healing

    … The utility of the commissioned ovine tibial sawbones were instrumental during the investigation and testing processes for the new intramedullary nail design. The new cross-locking mechanism was shown to have potential and warrants further studies. This thesis has investigated, characterised …

    unsw Repository record for Biological and mechanical investigations into tibial fracture fixation and healing (opens in a new tab)

  16. Design and characterization of additively manufactured compliant features for spinal implants

    … apply compressive loading to the CIDs placed on Sawbones specimens. One set of CIDs was tested until failure resulting in an average ultimate compressive strength of 281 N in resin and 2569 N in Ti64 which varied considerably based on device geometry. Another set of implants was tested in …

    waterloo Repository record for Design and characterization of additively manufactured compliant features for spinal implants (opens in a new tab)

  17. An Augmented Reality Haptic Training Simulator for Spinal Needle Procedures

    … The system is composed of a torso mannequin from Sawbones Inc., a MicronTracker2 optical tracking system from Claron Technology, a Sensable PHANToM Premium 1.5A haptic device and a graphical user interface (GUI) to display relevant visual feedback. The GUI allows the user to view the AR overlaid …

    queens Repository record for An Augmented Reality Haptic Training Simulator for Spinal Needle Procedures (opens in a new tab)

  18. X-Ray Interrogated Implantable Chemical and Strain Sensors for Monitoring Implant Associated Infections And Fracture Healing

    … via plain radiography. The sensor was mounted on Sawbones tibia models (fractured and allograft repaired) and human cadaveric tibia and tested under cyclic loading. The sensor displayed reversible and repeatable behavior with a slope of 0.096 mm/kg and fluid level noise of 50 to 80 micrometer …

    clemson Repository record for X-Ray Interrogated Implantable Chemical and Strain Sensors for Monitoring Implant Associated Infections And Fracture Healing (opens in a new tab)

  19. Beeinflussung der Verankerungsstabilität von Press-fit Pfannen durch die Rückflächenkonfiguration

    … werden jeweils in Kunstschaumblöcke der Fa. Sawbones® eingepresst. Die Kunstschaumblöcke aus geschlossenporigem Polyurethanschaum stellen Knochenersatzmaterial dar, welches als alternatives Testmedium für menschlichen spongiösen Knochen verwendet wird. Es werden Pfannenlager in die …

    fu-berlin Repository record for Beeinflussung der Verankerungsstabilität von Press-fit Pfannen durch die Rückflächenkonfiguration (opens in a new tab)

Page 1 of 2