Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 154 for “"Scan rate"”.

  1. Programmed Temperature Electrospray Ionization (ptESI) for Thermal Cycling of Proteins

    … both unfolding and refolding. ptESI uses fast scan rates, allowing for short experiment times, and results in data dense experiments. As mass spectra are acquired continuously while temperature is scanned. Both ubiquitin and lysozyme exhibited highly reversible unfolding and refolding at …

    washington Repository record for Programmed Temperature Electrospray Ionization (ptESI) for Thermal Cycling of Proteins (opens in a new tab)

  2. Electrochemical Quartz Crystal Microbalance Study Of Bismuth Underpotential Deposition On Ruthenium And On Electrochemically Formed Ruthenium Oxide

    … UPD shifts slightly to positive potential as the scan rate increases. The peak current ratio (IAnode/ICathode) of Bi UPD and Bi bulk increases as the scan rate increases. Bi monolayer coverage calculated from mass (MLMass) and from charge (MLCharge) with scan rates dependent are compared both in …

    unt Repository record for Electrochemical Quartz Crystal Microbalance Study Of Bismuth Underpotential Deposition On Ruthenium And On Electrochemically Formed Ruthenium Oxide (opens in a new tab)

  3. Effect of Fuel Cell Operating Potential Window on Pt/C Catalyst Durability

    … load cycling. It is further investi gated how scan rate affects catalyst durability. Based on previous research, possible causes and pathways of Pt degradation are discussed. Three catalysts from different producers with varying support surface area are examined with accelerated stress tests …

    chalmers Repository record for Effect of Fuel Cell Operating Potential Window on Pt/C Catalyst Durability (opens in a new tab)

  4. ADVANCED MATERIALS AND METHODS FOR THE FABRICATION OF ELECTROCHEMICAL SUPERCAPACITORS

    … by transmission electron microscopy (TEM), scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), X-ray diffraction (XRD), thermogravimetric analysis (TGA) and differential thermal analysis (DTA). The capacitive behavior of electrodes was investigated by cyclic voltammetry …

    mcmaster Repository record for ADVANCED MATERIALS AND METHODS FOR THE FABRICATION OF ELECTROCHEMICAL SUPERCAPACITORS (opens in a new tab)

  5. An Analysis of Helicopter Pilot Scan Techniques While Flying at Low Altitudes and High Speed

    … and experienced pilots reacted in terms of their scan patterns during a simulated high speed low level flight. The focus of this study was specifically on the flight regimes encountered by helicopter pilots. Information obtained from this research may aid training effectiveness specific to …

    nps Repository record for An Analysis of Helicopter Pilot Scan Techniques While Flying at Low Altitudes and High Speed (opens in a new tab)

  6. Anodic Oxidation of Pentaphenylcyclopentadienes

    … irreversible when tetra-n-butylammonium perchlorate (TBA^+ClO4^-) or tetra-n-butylammonium trifluoromethane sulfonate (TBA^+OTf^-) are used, and partially reversible when tetra-n-butylammonium tetrafluoroborate (TBA^+BF4^-) is used. Oxidation of 1,2,3,4,5-pentaphenyl-1-methylcyclopentadiene, …

    mcmaster Repository record for Anodic Oxidation of Pentaphenylcyclopentadienes (opens in a new tab)

  7. Interfacial Characterization of Chemical Vapor Deposition (Cvd) Grown Graphene and Electrodeposited Bismuth on Ruthenium Surface

    … and transferring graphene to different substrates have been investigated. The graphene growing on the copper substrate has an advantage of low solubility of carbon on the copper which allow us to grow mostly monolayer graphene. Graphene sheet of few centimeters can be transferred to 300nm …

    unt Repository record for Interfacial Characterization of Chemical Vapor Deposition (Cvd) Grown Graphene and Electrodeposited Bismuth on Ruthenium Surface (opens in a new tab)

  8. Development and comparison of algorithms for generating a scan sequence for a random access scanner

    <p>Many data acquisition systems incorporate high speed scanners to convert analog signals into digital format for further processing. Some systems multiplex many channels into a single scanner. A random access scanner whose scan sequence is specified by a table in random access memory will permit …

    ut-knoxville Repository record for Development and comparison of algorithms for generating a scan sequence for a random access scanner (opens in a new tab)

  9. Electrocatalytic-Frustrated Lewis pair hydrogen oxidation using novel benzothiazolium salts

    … 4). However, problems arose with the frustrated Lewis pair activation of the cycle with adduct formation. This is discussed further in Chapter 5. In chapter 1, several different ways of hydrogen production are discussed, from steam reformation to hydrogenases. Also included is the …

    east-anglia Download PDF for Electrocatalytic-Frustrated Lewis pair hydrogen oxidation using novel benzothiazolium salts (opens in a new tab)

  10. The development of advanced materials for electrodes and electrolytes in supercapacitors

    … provides capacitance around 177 F/g at the scan rate of 1 A/g current density which is highly improved compared to pure unaligned CNTs electrodes. On the other hand, supercapacitor electrodes can also achieve high energy and power by utilizing the composite materials of graphene, MoS2 and …

    rice Repository record for The development of advanced materials for electrodes and electrolytes in supercapacitors (opens in a new tab)

  11. Electrochemical detection of bromate in food at MCWNT/Ni/Pc and MWCNT/Co/Pc modified electrode

    … transmission electron microscopy (TEM), and scanning electron microscopy (SEM). The synthesized nanoparticles and nanocomposites were used to modify the glassy carbon electrode (GCE). The electrochemical characterization of the bare GCE and the modified electrodes (GCE-Co, GCE-Ni, GCE-MWCNTs, …

    nwu-za Repository record for Electrochemical detection of bromate in food at MCWNT/Ni/Pc and MWCNT/Co/Pc modified electrode (opens in a new tab)

  12. HIGH-SPEED ENDOSCOPIC OPTICAL COHERENCE TOMOGRAPHY AND ITS APPLICATIONS

    … to reach an axial resolution of 9.7 µm and an A-scan rate of 220 kHz. A Mach-Zehnder interferometer setup is used to achieve shot-noise limited detection. A generic OCT software platform is developed for data acquisition, processing, display, storage, and 3D visualization. Miniature OCT imaging …

    jhu Repository record for HIGH-SPEED ENDOSCOPIC OPTICAL COHERENCE TOMOGRAPHY AND ITS APPLICATIONS (opens in a new tab)

  13. Processing and properties of nanostructured thin film energy storage devices

    … (< 1.8 Ω). Specific capacitance of 110 F/g at a scan rate of 100 mV/s in 1 M H<sub>2</sub>SO<sub>4</sub> was achieved.</p> <p>The high rate performance of activated carbon-based electrodes ( ~2 <em>µ</em>m thickness) has been enhanced by reducing the contact resistance of electrode/current …

    oxford Repository record for Processing and properties of nanostructured thin film energy storage devices (opens in a new tab)

  14. Investigation of the Hydrogen Evolution Reaction and Hydrogen Oxidation Reaction on Nickel Single Crystal Electrodes in Alkaline Media

    … measurements in 0.10 M aqueous NaOH solution saturated with N2 gas at a scan rate of 50 mV sec1. After characterizing the electrodes, the activity of the HER on the Ni(hkl) electrodes was analyzed by linear sweep voltammetry (LSV) measurements at a potential scan rate of s = 0.10 V s–1 ensuring …

    queens Repository record for Investigation of the Hydrogen Evolution Reaction and Hydrogen Oxidation Reaction on Nickel Single Crystal Electrodes in Alkaline Media (opens in a new tab)

  15. Design and development of an endoscopic optical coherence tomography (OCT) imaging system

    … using a fibre-cantilever piezotube (PZT) scanner has been developed with a linear field-of-view of 0.5 mm and axial resolution of 10 μm at 1300 nm. The achieved A-scan rate is 200 kHz as defined by the swept source, and a B-scan rate of 1.4 kHz given by the fibre resonance frequency. The …

    cork Repository record for Design and development of an endoscopic optical coherence tomography (OCT) imaging system (opens in a new tab)

  16. Volume change associated with the low- to physiological-temperature conformational change in Thermomyces lanuginosus xylanase

    … change in heat capacity as detected by slow-scan-rate differential scanning calorimetry and occurs at a temperature between that where crystals are formed for x-ray structure determination (4°C) and the physiological temperature (55°C). A volume change ΔV ≈-190 L/mol was calculated associated …

    twu Repository record for Volume change associated with the low- to physiological-temperature conformational change in Thermomyces lanuginosus xylanase (opens in a new tab)

  17. Electrochemical evaluation of zinc electrolyte

    … temperature, H₂SO₄ and Zn concentration, and scan rate. The solution temperature was found to be the most significant factor followed by scan rate and zinc concentration. Based on the screening design data, mathematical equations were developed to predict the nucleation potential of the …

    must-thes Repository record for Electrochemical evaluation of zinc electrolyte (opens in a new tab)

  18. Design and prototype of a trimodal, wireless, neural interface device with electrical and electrochemical neural recording

    … an FSCV waveform generator with a 400V/s scan rate and a voltage sweep range of -0.25V to 1.36V. The optogenetic stimulation unit is a wirelessly controlled LED configurable for frequencies between 1Hz to 10Hz and an on-pulse time between 1 ms and 10 ms. The data acquisition rate for …

    texas Repository record for Design and prototype of a trimodal, wireless, neural interface device with electrical and electrochemical neural recording (opens in a new tab)

  19. Electrochemical Depostion of Bismuth on Ruthenium and Ruthenium Oxide Surfaces

    … and 0.55V (vs. KCl sat. Ag/AgCl) and a 20mV/s scan rate. Grazing incidence x-ray diffraction (GIXRD) determined the freshly prepared thin film electrode was hexagonally close-packed. After thermally oxidizing at 600°C for 20 minutes, the thin film adopts the tetragonal structure consistent with …

    unt Repository record for Electrochemical Depostion of Bismuth on Ruthenium and Ruthenium Oxide Surfaces (opens in a new tab)

Page 1 of 8