Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 610 for “"Scanning Microscopy"”.
-
Reducing Chatter in Knife-Edge Scanning Microscopy
The Knife-Edge Scanning Microscope (KESM) employs a novel form of physical sectioning microscopy: Imaging of tissue while sectioning. KESM was developed in the Brain Networks Lab (BNL) at Texas A&M University. The KESM has been used to section animal tissue embedded in a plastic block using a …
-
Nanopatterning of Ferroelectric Polymer and High-resolution Pyroelectric Scanning Microscopy
… have implemented a high-resolution Pyroelectric Scanning Microscopy (PSM) system that achieves high lateral resolution by means of a tightly focused violet laser beam for localized heating and high modulation frequency to minimize thermal diffusion. The system achieved a lateral resolution of …
-
Distinguishing Calliphorid Puparia Through Application of Confocal Laser Scanning Microscopy
… but are character conservative. Historically, scanning electron microscopy (SEM) has been used for characterization, a technique which is not only time consuming but often expensive, effectively making large numbers of specimens impossible to quantify. As an alternative, confocal laser scanning …
-
HYPERSPECTRAL LINE-SCANNING MICROSCOPY FOR HIGH-SPEED MULTICOLOR QUANTUM DOT TRACKING
… Here we introduce a high-speed laser line-scanning hyperspectral microscope that is designed to track quantum dot labeled proteins at 27 frames/sec over an area of 28 um2 using 128 spectral channels spanning the range from 500 to 750 nm. This instrument simultaneously excites 8 species of …
-
Acquisition and reconstruction of brain tissue using knife-edge scanning microscopy
… These data sets are retrieved using knife-edge scanning microscopy, a new technique developed in the Brain Networks Laboratory at Texas A&M University. This technique allows the imaging of tissue as it is cut by an ultramicrotome. In this thesis the development of a knife-edge scanner is …
-
Topics in living cell miultiphoton laser scanning microscopy (MPLSM) image analysis
Multiphoton laser scanning microscopy (MPLSM) is an advanced fluorescence imaging technology which can produce a less noisy microscope image and minimize the damage in living tissue. The MPLSM image in this research is the dehydroergosterol (DHE, a fluorescent sterol which closely mimics those of …
-
High Dynamic Range Image Processing of Confocal Laser Scanning Microscopy Data
… tube imaging sensor for a confocal laser scanning microscope has been developed. This method uses data from all the available images in order to generate images which simulate an imaging sensor having unlimited dynamic range and simultaneously reduces the noise in the pixel intensity …
-
Three-Dimensional Volume Reconstruction From Fluorescent Confocal Laser Scanning Microscopy Imagery
The broader impact of my work is in providing the algorithms in a form of web-enabled tools to the medical community so that medical researchers can minimize laborious and time intensive 3D volume reconstructions using the tools and computational resources at NCSA.
-
Investigating size, charge, and fluorescence of nanoparticles with laser-scanning microscopy
Nanodeeltjes zijn deeltjes die kleiner zijn dan de golflengte van licht en spelen een cruciale rol in de geneeskunde, elektronica en detectietechnologieën. Ze bestuderen is echter een uitdaging omdat ze te klein zijn om met gewone microscopen te zien. Dit onderzoek richt zich op het ontwikkelen van …
-
3D Characterization of Human Knee Cartilage affected by Osteoarthritis Using Laser Scanning Microscopy
… hydrated human cartilage samples using laser scanning confocal microscopy, and (b) to identify the numerical parameters that could effectively describe the distinct cartilage surface morphologies for each OA grade. Human knee cartilage samples with three different OA grades (OA I, II and III) …
-
Photon Event Distribution Sampling (PEDS): Image Formation & High Precision Particle Localization in Scanning Microscopy
At the limit of resolution of light microscopy, high magnification images are conventionally formed using relatively large pixels because acquiring images with smaller pixels results in lost signal too great to be beneficial. At resolution near the diffraction limit, the measured position of a …
-
COMPREHENSIVE PERFORMANCE EVALUATION AND OPTIMIZATION OF HIGH THROUGHPUT SCANNING MICROSCOPY FOR METAPHASE CHROMOSOME IMAGING
Specimen scanning is a critically important tool for diagnosing the genetic diseases in today’s hospital. In order to reduce the clinician’s work load, many investigations have been conducted on developing automatic sample screening techniques in the last twenty years. However, the currently …
-
Visualization of autoimmune processes in chronic neuroinflammation by means of two-photon laser scanning microscopy
… I applied time lapse two-photon laser scanning microscopy (TPLSM) to investigate the cellular migration of various T cell subsets in living brain tissue. First, T cells, isolated from atorvastatin treated mice or after pharmacological activation of the bradykinin receptor B1 revealed a …
-
Agglutination behavior of lactococci as determined by enzyme linked immunosorbent assay and laser scanning microscopy
Thesis (M.S.)--Michigan State University. Department of Food Service and Human Nutrition, 1998
-
Confocal Laser Scanning Microscopy As A Tool For The Investigation Of Tetracycline Fluorescence In Archaeologicalhuman Bone
… of remains postmortem. Standard epifluorescence microscopy is the most common tool employed in the analysis of these labels. Though valuable, this technique is limited by its inability to penetrate bone three-dimensionally and its inclusion of out-of-focus light, possibly disrupting accurate …
-
Acousto-optic multiphoton laser scanning microscopy and multiphoton photon counting spectroscopy: Applications and implications for optical neurobiology
… existing multiphoton microscope systems based on scanning mirrors do not allow optical recordings to be obtained from more than a handful of sites simultaneously at the high rates required to capture the fast physiological signals of interest (>100Hz for Ca2+ signals, >1kHz for membrane potential …
Page 1 of 31