Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 15 of 15 for “"Scatter imaging"”.

  1. X-ray Coherent Scatter Imaging for Intra-operative Margin Detection in Breast Conserving Surgeries

    … this dissertation, we describe an x-ray coherent scatter imaging technique for intra-operative margin detection with greater accuracy and speed than currently available techniques. The method is based on cross-sectional imaging of the differential coherent scatter cross section in the sample. We …

    duke Repository record for X-ray Coherent Scatter Imaging for Intra-operative Margin Detection in Breast Conserving Surgeries (opens in a new tab)

  2. Identifying Humans by the Shape of Their Heartbeats and Materials by Their X-Ray Scattering Profiles

    … identification involves matching their x-ray scattering profiles with a database of known materials. Classical biometric traits such as fingerprints, facial images, speech, iris and retinal scans are plagued by potential circumvention they could be copied and later used by an impostor. To …

    wustl Repository record for Identifying Humans by the Shape of Their Heartbeats and Materials by Their X-Ray Scattering Profiles (opens in a new tab)

  3. Evaluation Of Nozzle Geometry On High Pressure Gasoline Direct Injection Spray Atomization

    … results with near-field shadowgraph and Mie scatter imaging as well as phase-contrast x-ray imaging is provided. When near-field experimental imaging validated the simulation results further investigation of the fundamental flow mechanism internal to the injector was studied using VOF-LES to …

    wayne-thes Repository record for Evaluation Of Nozzle Geometry On High Pressure Gasoline Direct Injection Spray Atomization (opens in a new tab)

  4. Flow Independent Fuel Injection for More Consistent Liquid Combustion Using Pintile Injectors

    … parameters on flow independence, using Mie scatter imaging and phase Doppler particle analysis. The results of that investigation yielded an optimal overarching geometry for pintiles. This knowledge was then refined by looking at specific face characteristics of the obstructions, primarily …

    ucf Repository record for Flow Independent Fuel Injection for More Consistent Liquid Combustion Using Pintile Injectors (opens in a new tab)

  5. MOBILE, HYBRID COMPTON/CODED APERTURE IMAGING FOR DETECTION, IDENTIFICATION AND LOCALIZATION OF GAMMA-RAY SOURCES AT STAND-OFF DISTANCES

    … truck-based, hybrid gamma-ray spectroscopic and imaging system able to quickly detect, identify and localize, radiation sources at standoff distances through improved sensitivity provided by multiple detection modes while minimizing the false alarm rate. Reconstruction of gamma-ray sources is …

    unm Repository record for MOBILE, HYBRID COMPTON/CODED APERTURE IMAGING FOR DETECTION, IDENTIFICATION AND LOCALIZATION OF GAMMA-RAY SOURCES AT STAND-OFF DISTANCES (opens in a new tab)

  6. Physics-Based Modeling for Advanced Optical Imaging Systems

    This dissertation investigates advanced optical imaging systems through a physics-based modeling framework spanning geometric optics, wave propagation, and coherence theory. Rather than treating imaging architectures in isolation, this work examines how distinct physical descriptions of light …

    arizona-thes Repository record for Physics-Based Modeling for Advanced Optical Imaging Systems (opens in a new tab)

  7. Improving Object Classification in X-ray Luggage Inspection

    … for using x-ray dual-energy transmission and scatter imaging technologies more effectively. Followed by an introduction and brief overview of x-ray detection technologies, a model for a prototype x-ray scanning system, which was built at Virginia Tech, is given. This model has primarily been …

    vt Repository record for Improving Object Classification in X-ray Luggage Inspection (opens in a new tab)

  8. Development and Characterization of a Fast Neutron Imaging Telescope (FNIT) for 1--20 MeV Neutrons From the Sun and Nuclear Material

    … and complete characterization of a double scatter telescope for 1--20 MeV neutrons intended for applications in solar physics and nuclear security. In high-energy solar physics, detecting the presence of low energy accelerated ions in the low corona is recognized as an important goal. The …

    unh-thes Repository record for Development and Characterization of a Fast Neutron Imaging Telescope (FNIT) for 1--20 MeV Neutrons From the Sun and Nuclear Material (opens in a new tab)

  9. Diesel spray mixing limited vaporization with non-ideal and multi-component fuel thermophysical property effects

    … tests, with sprays characterized using Mie back scatter imaging diagnostics. Liquid phase spray parameter trends agree with literature. Fluctuations in liquid length about a quasi-steady value are quantified, along with plume to plume variations. Hypotheses are developed for their causes …

    mtu Repository record for Diesel spray mixing limited vaporization with non-ideal and multi-component fuel thermophysical property effects (opens in a new tab)

  10. Coded Aperture X-ray Tomographic Imaging with Energy Sensitive Detectors

    <p>Coherent scatter imaging techniques have experienced a renaissance in the past two decades from an evolution of detector technology and computational imaging techniques. X-ray diffraction requires a precise knowledge of object location and is time consuming; transforming diffractometry into a …

    duke Repository record for Coded Aperture X-ray Tomographic Imaging with Energy Sensitive Detectors (opens in a new tab)

  11. A spectroscopic Compton scattering reconstruction algorithm for 2D cross-sectional view of breast CT geometry

    X-ray imaging exams are widely used procedures in medical diagnosis. Whenever an x-ray imaging procedure is performed, it is accompanied by scattered radiation. Scatter is a significant contributor to the degradation of image quality in breast CT. This work uses our understanding of the physics of …

    manitoba Repository record for A spectroscopic Compton scattering reconstruction algorithm for 2D cross-sectional view of breast CT geometry (opens in a new tab)

  12. Characterisation of imperfections in hollow core photonic bandgap fibres

    … of characterisation methods, such as IR side-scatter imaging, X-ray tomographic analysis and optical side scattering radiometry, aimed at identifying defects and imperfections that arise in HC-PBGFs. Through these<br/>techniques, I studied the morphology and longitudinal evolution (e.g. …

    soton Download PDF for Characterisation of imperfections in hollow core photonic bandgap fibres (opens in a new tab)

  13. Joint Estimation of Attenuation and Scatter for Tomographic Imaging with the Broken Ray Transform

    The single-scatter approximation is fundamental for many tomographic imaging problems. This class broadly includes x-ray scattering imaging and optical scatter imaging for certain media. In all cases, noisy measurements are affected by both local events and nonlocal attenuation. Related …

    wustl Repository record for Joint Estimation of Attenuation and Scatter for Tomographic Imaging with the Broken Ray Transform (opens in a new tab)

  14. The Development and Validation of a First Generation X-Ray Scatter Computed Tomography Algorithm for the Reconstruction of Electron Density Breast Images Using Monte Carlo Simulation

    Breast CT is a promising modality whose inherent scatter could be used to reconstruct electron density (rho_e) images. This has led us to investigate the benefits of reconstructing linear attenuation coefficient (mu) and (rho_e) images of the breast. First generation CT provides a cost-effective …

    manitoba Repository record for The Development and Validation of a First Generation X-Ray Scatter Computed Tomography Algorithm for the Reconstruction of Electron Density Breast Images Using Monte Carlo Simulation (opens in a new tab)