Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 92 for “"Scattered radiation"”

  1. Correction of scattered radiation in multi-energy radiography and tomography

    L’imagerie à rayons X couplée aux détecteurs résolus en énergie permet de différencier les matériaux présents et d’estimer leurs contributions respectives. Cependant, ces techniques nécessitent des images très précises. La présence du rayonnement diffusé conduit à une perte du contraste spatial et …

    star-france Repository record for Correction of scattered radiation in multi-energy radiography and tomography (opens in a new tab)

  2. Spectra of scattered radiation at points off the beam axis

    … a knowledge of the spectral distribution or radiation reaching a point is very important. Although the dose gives the amount of radiation at the point, it is the spectral distribution which determines the effects, for instance, the energy absorbed by the irradiated medium. In an irradiated …

    sask Repository record for Spectra of scattered radiation at points off the beam axis (opens in a new tab)

  3. Investigation of a Two Detector Method for Separating Primary and Scattered Radiation

    Made available in DSpace on 2017-07-06T18:55:03Z (GMT). No. of bitstreams: 3 Laughton_Craig_A_MS.pdf: 63869291 bytes, checksum: 22c042a44349f01a9318b0eb29bbd847 (MD5) Laughton_Craig_A_MS_ABS.pdf: 595141 bytes, checksum: fdfeba60c34ca0ee2de9fc68436a5e06 (MD5) license.txt: 4813 bytes, checksum: …

    uiuc Repository record for Investigation of a Two Detector Method for Separating Primary and Scattered Radiation (opens in a new tab)

  4. Evaluation of Scattered Radiation in a Calibration Range Using Exposure Rate Energy Spectra

    … for calibrating protection level dosimeters, scattered radiation should contribute less than 5 percent of the exposure. In previous work, we reported the results of an MCNP analysis of the shadow shield technique that was performed for a calibration range with a Cs-137 irradiator. This thesis …

    ohiolink Repository record for Evaluation of Scattered Radiation in a Calibration Range Using Exposure Rate Energy Spectra (opens in a new tab)

  5. Monte Carlo analysis of scattered radiation in time-of-flight positron emission tomography

    … vivo radiotracer distribution. The presence of scattered coincidences, caused by deflection of one or both of the detected annihilation photons, manifests itself as a degradation in image quality and quantitative accuracy, thus compromising the diagnostic value of the image. The purpose of this …

    ohiolink Repository record for Monte Carlo analysis of scattered radiation in time-of-flight positron emission tomography (opens in a new tab)

  6. Spectral Signature and Correction of Scattered Radiation in Energy-Resolved X-ray Imaging

    … Exploiting spectral information of the incident radiation promises revolutionary approaches to material identification and characterization. However, radiation that scatters from the object and reaches the detector is a long-standing problem that reduces image quality and quantitative accuracy. …

    houston Repository record for Spectral Signature and Correction of Scattered Radiation in Energy-Resolved X-ray Imaging (opens in a new tab)

  7. Full-wave approach to the scattered radiation fields by rough surfaces: Numerical and iterative solutions

    … equations have been solved for the radiation fields scattered from rough surfaces using iterative approaches for the single scatter and the double-scatter. A numerical method is developed in this dissertation to solve the generalized telegraphist's equations for the diffuse scattered …

    nebraska Repository record for Full-wave approach to the scattered radiation fields by rough surfaces: Numerical and iterative solutions (opens in a new tab)

  8. Measurement of the spectra of multiply-scattered radiation in a medium irradiated with Co60 gamma rays

    A knowledge of the spectral distribution of scattered radiation at a point is of value in planning effective radiation therapy and adequate personnel protection. Some spectra have been calculated theoretically or measured experimentally for a few particular irradiation conditions. In this …

    sask Repository record for Measurement of the spectra of multiply-scattered radiation in a medium irradiated with Co60 gamma rays (opens in a new tab)

  9. Evaluation of ISO 4037-1:1996 and the Shadow Shield Technique for the Measurement of Scattered Radiation

    … methods of X-Ray and Gamma-Ray reference radiation for calibrating protection level dosimeters and rate dosimeters. The standard limits scattered radiation to 5% and provides a test that one may use to check conformity with the scatter specification. Through the use of an MCNP model built …

    ohiolink Repository record for Evaluation of ISO 4037-1:1996 and the Shadow Shield Technique for the Measurement of Scattered Radiation (opens in a new tab)

  10. Enhancement of the Scattered Radiation Display System Dose Management Module for Occupational Eye-Lens Dose in Fluoroscopic Interventional Procedures

    … exposure that makes staff members susceptible to radiation-induced health hazards including eye-lens cataract formation. Our group has previously developed the Dose Tracking System (DTS) to monitor the patient’s skin dose during long FGI procedures; however, the radiation dose is a concern not …

    buffalo Repository record for Enhancement of the Scattered Radiation Display System Dose Management Module for Occupational Eye-Lens Dose in Fluoroscopic Interventional Procedures (opens in a new tab)

  11. An experimental and theoretical approach to correct for the scattered radiation in an X-ray computer tomography system for industrial applications

    … 450 kV X-ray tubes is the high amount of scattered radiation which is added to the primary radiation (signal). This stray radiation leads to a significant degradation of the image quality. A better understanding of the scattering and methods to reduce its effects are therefore necessary to …

    bologna Repository record for An experimental and theoretical approach to correct for the scattered radiation in an X-ray computer tomography system for industrial applications (opens in a new tab)

  12. Vibrational cooling of a trapped atom : its evolution to electromagnetically induced transparency, the development of the scattered radiation field and signatures of correlation and entanglement

    … To explore the origin of cooling, we study the scattered field spectrum from the trapped atom. The spectrum based on the mean of two-time correlation function is computed by the quantum regression theory. The spectrum in the frequency range is the Fourier transform of the multitime correlation …

    freiburg-diss Repository record for Vibrational cooling of a trapped atom : its evolution to electromagnetically induced transparency, the development of the scattered radiation field and signatures of correlation and entanglement (opens in a new tab)

  13. The Scattered Radiation Display System: A New Paradigm for Staff Member Dose Management and Training for Fluoroscopically-Guided Interventional Procedures Using Virtual Reality, Monte Carlo Simulations, and Artificial Intelligence

    … (ALARA) principle maintains that absorbed radiation dose for both the patient and staff members should be minimized while concurrently ensuring proper treatment outcome. Standard methods exist for monitoring staff dose levels either during or after procedures in the form of real-time …

    buffalo Repository record for The Scattered Radiation Display System: A New Paradigm for Staff Member Dose Management and Training for Fluoroscopically-Guided Interventional Procedures Using Virtual Reality, Monte Carlo Simulations, and Artificial Intelligence (opens in a new tab)

  14. Surface enhanced Raman scattering from silver electrodes

    … the enhancement,^the angular dependence of the scattered radiation was measured^from pyridine adsorbed on an evaporated silver electrode. Both^polycrystalline and single crystalline silver films were used. The^angular dependence of the scattered radiation from these films^showed that the metal …

    iastate Repository record for Surface enhanced Raman scattering from silver electrodes (opens in a new tab)

  15. Monte-Carlo Calculations for Patient and Staff Dose Management during Fluoroscopically-Guided Procedures

    … during long interventional procedures; however, radiation dose is a concern not only for the patient but also for the personnel in the procedure room. In recent years, the number and types of fluoroscopically-guided procedures have increased dramatically. The NCRP has estimated that 17 million …

    buffalo Repository record for Monte-Carlo Calculations for Patient and Staff Dose Management during Fluoroscopically-Guided Procedures (opens in a new tab)

  16. Modeling x-ray scattering process and applications of the scattering model

    … model has been improved to account for scattered radiation effects. The second technique is "Inspection with Compton backscattering", where a new simulation model has been developed;The effect of scattered radiation on a simulated radiographic image can be insignificant, equally …

    iastate Repository record for Modeling x-ray scattering process and applications of the scattering model (opens in a new tab)

  17. ΠΟΣΟΤΙΚΟΣ ΥΠΟΛΟΓΙΣΜΟΣ ΜΕΓΕΘΩΝ ΟΡΓΑΝΩΝ ΚΑΤΑ ΤΗΝ ΣΠΙΝΘΗΡΟΓΡΑΦΗΣΗ

    … TRACER UPTAKE. IN THIS WORK, THE PRINCIPLE OF SCATTERED RADIATION PRODUCTION WAS USED IN ORDER TO DEVELOP A MATHEMATICAL MODEL WHICH PERMITTED THE CALCULATION OF ORGAN DEPTH. THIS MODEL WAS USED FOR THE CALCULATION OFKIDNEY SIZE AND UPTAKE DURING DMSA SCINTIGRAPHY. COMPARISON OF RESULTS WITH …

    greece Repository record for ΠΟΣΟΤΙΚΟΣ ΥΠΟΛΟΓΙΣΜΟΣ ΜΕΓΕΘΩΝ ΟΡΓΑΝΩΝ ΚΑΤΑ ΤΗΝ ΣΠΙΝΘΗΡΟΓΡΑΦΗΣΗ (opens in a new tab)

  18. The influence of scatter and beam hardening in X-ray computed tomography for dimensional metrology

    … (CT) for making dimensional measurements. Scattered radiation and beam hardening are two phenomena that are well-known to severely degrade the quality of cone-beam CT data; however, the impact they have on dimensional measurements is not well understood. The aim of this work is to better …

    soton Repository record for The influence of scatter and beam hardening in X-ray computed tomography for dimensional metrology (opens in a new tab)

Page 1 of 5