Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 10 of 10 for “"Schmidt-Boelter"”.

  1. Convection Calibration of Schmidt-Boelter Heat Flux Gages in Shear and Stagnation Air Flow

    This work reports the convection calibration of Schmidt-Boelter heat flux gages in shear and stagnation air flow. The gages were provided by Sandia National Laboratories and included two one-inch diameter and two one-and-one-half-inch diameter Schmidt-Boelter heat flux gages. In order to calibrate …

    vt Repository record for Convection Calibration of Schmidt-Boelter Heat Flux Gages in Shear and Stagnation Air Flow (opens in a new tab)

  2. Convective Heat Flux Sensor Validation, Qualification and Integration in Test Articles

    … flux on a hemisphere. A 1/8 in. fast response Schmidt-Boelter gage and a 1/16 in. Coaxial thermocouple mounted in ¾ in. diameter stainless steel, MACOR, and Graphite hemispheres were chosen as the test articles for this study. An inverse heat flux calculation was performed using the coaxial …

    vt Repository record for Convective Heat Flux Sensor Validation, Qualification and Integration in Test Articles (opens in a new tab)

  3. Coupling of Fluid & Solid Thermal Models to Correct Heat Flux Measurements Taken on Launch Vehicles

    … layers as well as thermal radiation. Typically, Schmidt-Boelter gauges measure the incident heat flux based on the one-Dimensional Fourier's law. This instrumentation, when surrounded by low-conductivity insulation, has an exposed surface temperature significantly lower than the insulation. A …

    embry-riddle Repository record for Coupling of Fluid & Solid Thermal Models to Correct Heat Flux Measurements Taken on Launch Vehicles (opens in a new tab)

  4. Integration and Evaluation of Unsteady Temperature Gages for Heat Flux Determination in High Speed Flows

    … of time. In both tests, reference Medtherm Schmidt-Boelter gages ensure consistent heat fluxes are applied across all runs. The time response of the entire electrical system was determined by subjecting the gage to a nanosecond scale laser pulse. Two experimental campaigns were conducted in …

    vt Repository record for Integration and Evaluation of Unsteady Temperature Gages for Heat Flux Determination in High Speed Flows (opens in a new tab)

  5. Quantification of the Fire Thermal Boundary Condition

    … were then compared to results obtained with a Schmidt-Boelter gage and a plate thermometer. The hybrid heat flux gage predicted a cold surface heat flux within 5% of cold surface heat fluxes measured with a Schmidt-Boelter gage. Adiabatic surface temperature measurements compared well with the …

    vt Repository record for Quantification of the Fire Thermal Boundary Condition (opens in a new tab)

  6. A Method for Measurement of Spatially Resolved Radiation Intensity and Radiative Fraction of Laminar Flames of Gaseous and Solid Fuels

    … to collect monochromatic (900 nm) images and a Schmidt-Boelter heat flux gauge. The high spatial resolution provided by the images of the camera allows for a multi-emitter treatment of the 2-6 cm flames. The flame’s radius and intensity are extracted from the images and presented as two curves …

    maryland Repository record for A Method for Measurement of Spatially Resolved Radiation Intensity and Radiative Fraction of Laminar Flames of Gaseous and Solid Fuels (opens in a new tab)

  7. The Physical Mechanism of Heat Transfer Augmentation in Stagnating Flows Subject to Freestream Turbulence and Related Studies

    … and torch firing. Finally, the performance of Schmidt-Boelter heat flux sensors were examined in both shear and stagnation flow using two custom designed convection calibration facilities. Calibration results were evaluated using an analytical sensitivity model based on an overall sensor …

    vt Repository record for The Physical Mechanism of Heat Transfer Augmentation in Stagnating Flows Subject to Freestream Turbulence and Related Studies (opens in a new tab)

  8. Thermal Characterization of a Pool Fire in Crosswind With and Without a Large Downwind Blocking Object

    … simulating those found in wind-blown fires. Schmidt-Boelter, Gardon and Hemispherical Heat Flux gauges and a Directional Flame Thermometer were exposed to a convective flow and to radiation from a cone calorimeter heater. Measurements were influenced by differences between the calibration and …

    waterloo Repository record for Thermal Characterization of a Pool Fire in Crosswind With and Without a Large Downwind Blocking Object (opens in a new tab)

  9. Enhanced directional flame thermometer modeling and experiments

    … flux measurements using conventional gauges like Schmidt Boelter (SB) and Gardon gauges. Also, both the SB and Gardon gauges typically require cooling, which is difficult to provide at every location that one would want to measure heat flux in a standard fire testing compartment with dimensions 3 …

    texas Repository record for Enhanced directional flame thermometer modeling and experiments (opens in a new tab)

  10. Development of a Non-Intrusive Radiative Heat Flux Diagnostic for Reacting Boundary Layer Combustion

    … with intrusive measurements using water-cooled Schmidt-Boelter heat flux gauge (SBG) and thin-skin calorimeters (TSC). The influence of oxygen concentration in oxidizer blends on soot formation and RHF are studied experimentally and numerically using 1D steady-state diffusion flamelets coupled …

    buffalo Repository record for Development of a Non-Intrusive Radiative Heat Flux Diagnostic for Reacting Boundary Layer Combustion (opens in a new tab)