Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 9 of 9 for “"Scintillating crystal"”

  1. Implementation of crystal mapping and energy calibration procedures for PET block detectors with pixelated scintillators

    … (PET) block detector architecture uses pixelated scintillating crystals coupled to a position sensitive photomultiplier tube (PS-PMTs) or a silicon photomultiplier (SiPM) array. In such detector designs a light guide layer between the finely segmented scintillating crystal array and coarsely …

    regina Repository record for Implementation of crystal mapping and energy calibration procedures for PET block detectors with pixelated scintillators (opens in a new tab)

  2. Measurement of sm electro-weak parameters in reactor antineutrino-electron scattering in texono experiment

    … at KS Nuclear Power Station with 200 kg CsI(Tl) scintillating crystal detector located at a distance of 28 m from the 2.9 GW reactor core giving total flux of 6:52X10^12 cm^-2s^-1 in average at the experimental site. New analysis techniques and background suppression methods were developed. In …

    metu Repository record for Measurement of sm electro-weak parameters in reactor antineutrino-electron scattering in texono experiment (opens in a new tab)

  3. TOWARDS AN IMPROVED MEASUREMENT OF THE CEVNS PROCESS WITH THE CENNS-10 LIQUID ARGON DETECTOR

    … observation of CEvNS using a 14.6-kg CsI[Na] scintillating crystal in 2017, and again in 2020 using a 24-kg single-phase liquid argon detector. Following the 2020 result, the liquid argon detector continued to operate, tripling the amount of data collected in the previous analysis. For this …

    iu Repository record for TOWARDS AN IMPROVED MEASUREMENT OF THE CEVNS PROCESS WITH THE CENNS-10 LIQUID ARGON DETECTOR (opens in a new tab)

  4. Linearly polarised pion photoproduction on the deuteron

    … deuterium target using the Mainzer Microtron and Crystal Ball detector at the Johannes Gutenberg Universität in Mainz. These results, particularly the π 0 n channel, provide current models attempting to describe the nucleon resonance spectrum and properties with essential constraints. Measurements …

    glasgow Repository record for Linearly polarised pion photoproduction on the deuteron (opens in a new tab)

  5. Studies of the responses of liquid and solid targets for direct dark matter searches.

    … factor for sodium recoils in a 2-inch Nal(Tl) scintillating crystal has been measured at room temperature. The crystal has been exposed to 2.45 MeV mono-energetic neutrons generated by a deuterium-deuterium fixed target accelerator in the energy range 10 to 100 keV nuclear recoil energy. A …

    whiterose Repository record for Studies of the responses of liquid and solid targets for direct dark matter searches. (opens in a new tab)

  6. Dark Matter Search with Cryogenic Phonon-Light Detectors

    … search. CRESST detectors consist of a 300g CaWO4 scintillating crystal operated as a cryogenic calorimeter in close proximity to a second much smaller cryogenic calorimeter used to detect the scintillation light produced in the target crystal. The lower light yield of nuclear recoils, caused by …

    lmu-germany Repository record for Dark Matter Search with Cryogenic Phonon-Light Detectors (opens in a new tab)

  7. Cryogenic phonon-scintillation detectors with PMT readout for rare event search experiments and characterisation of a PMT at milli-Kelvin temperatures

    … thesis demonstrates a cryogenic detector with a scintillating crystal as the absorber, equipped with a Neutron Transmutation Doped Germanium (NTD-Ge) phonon sensor and a Hamamatsu R8520-06 photomultiplier tube (PMT) with platinum underlay as the light detector. The PMT is powered by a …

    oxford Repository record for Cryogenic phonon-scintillation detectors with PMT readout for rare event search experiments and characterisation of a PMT at milli-Kelvin temperatures (opens in a new tab)

  8. Étude et développement d'un imageur TEP ambulatoire pour le suivi thérapeutique individualisé en cancérologie

    L'imagerie médicale remonte à la fin du XIXe siècle avec la découverte des rayons X par Röntgen. Depuis, de nombreuses modalités d'imagerie ont été développées, et sont aujourd'hui utilisées dans une large gamme d'indications cliniques. L'imagerie TEP (Tomographie par Émission de Positron) est une …

    star-france Repository record for Étude et développement d'un imageur TEP ambulatoire pour le suivi thérapeutique individualisé en cancérologie (opens in a new tab)

  9. A novel phonon-scintillation cryogenic detector and cabling solution for dark matter direct detection

    … consists of a phonon detector based on a CaMoO4 scintillating crystal as the target with an attached NTD-Ge sensor as the thermometer, and a light detector based on a low-temperature PMT. To provide the high voltage necessary for PMT operation while ensuring the detector module can be cooled down …

    oxford Repository record for A novel phonon-scintillation cryogenic detector and cabling solution for dark matter direct detection (opens in a new tab)