Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 67 for “"Scintillator detector"”.

  1. Neutron-Gamma Discrimination in Elpasolite Scintillator Detector

    … be detected and analyzed, in particular, using scintillator detectors. Various electronic data acquisition systems and data analysis methods have been employed to record and characterize neutron and photon signatures. The goal of this thesis is to develop a new method of discrimination between …

    unlv Repository record for Neutron-Gamma Discrimination in Elpasolite Scintillator Detector (opens in a new tab) Download PDF for Neutron-Gamma Discrimination in Elpasolite Scintillator Detector (opens in a new tab)

  2. 3D Scintillator Detector Quenching Characterization For Scanning Proton Beams

    … assurance measurements leading to sophisticated detector setups and time consuming measurements. Fast 3D measurements are therefore desirable to verify the complex dose distribution and to enable the utilization of the full potential of proton therapy. The overall objective of this project is to …

    uthsc Repository record for 3D Scintillator Detector Quenching Characterization For Scanning Proton Beams (opens in a new tab)

  3. A Prompt D-D Neutron Calibration Of A Plastic Scintillator Detector

    … of the stable neutron generator used in the scintillator calibration was performed using a silver activation detector (PT-502) designed by LASL. The data obtained for the distance curve in this work was least squares fit to with the corresponding LASL data and matched with a maximum error of …

    unm Repository record for A Prompt D-D Neutron Calibration Of A Plastic Scintillator Detector (opens in a new tab)

  4. Development and testing of an organic scintillator detector for fast neutron spectrometry

    The use of organic scintillators is an established method for the measurement of neutron spectra above several hundred keV. Fast neutrons are detected largely by proton recoils in the scintillator resulting from neutron elastic scattering with hydrogen. This leads to a smeared rectangular …

    gatech Repository record for Development and testing of an organic scintillator detector for fast neutron spectrometry (opens in a new tab)

  5. TOTAL NEUTRON CROSS SECTION MEASUREMENT ON HYDROCARBON WITH A NOVEL 3D-PROJECTION SCINTILLATOR DETECTOR

    … electromagnetic process and thus can escape detectors without visible energy deposition. As such, neutrons present a challenge in anti(neutrino) reconstruction when they're part of the outgoing particles from the (anti)neutrino interaction. To address this challenge, the main target in T2K's …

    penn Repository record for TOTAL NEUTRON CROSS SECTION MEASUREMENT ON HYDROCARBON WITH A NOVEL 3D-PROJECTION SCINTILLATOR DETECTOR (opens in a new tab)

  6. Measurements of neutrino interactions on water using a fine-grained scintillator detector with water targets

    … For the T2K experiment, which has a near detector with a primarily carbon target and a far detector with an oxygen target, the cross-section difference is important for correctly comparing the neutrino fluxes at the two detectors. This dissertation presents a first measurement of the ratio …

    ubc Repository record for Measurements of neutrino interactions on water using a fine-grained scintillator detector with water targets (opens in a new tab) Download PDF for Measurements of neutrino interactions on water using a fine-grained scintillator detector with water targets (opens in a new tab)

  7. The Diffuse Supernova Neutrino Background and Pre-Supernova Neutrinos in the SNO+ Liquid Scintillator Detector

    … could potentially be detectable by neutrino detectors on Earth. A pre-supernova monitor performs a continuous search for events above background levels, in order to provide a potential alert that a supernova event is imminent before any optical signals have been detected. This thesis presents …

    queens Repository record for The Diffuse Supernova Neutrino Background and Pre-Supernova Neutrinos in the SNO+ Liquid Scintillator Detector (opens in a new tab)

  8. A measurement of the mean life of the positive muon to a precision of 11 parts per million

    … ferromagnetic target, which was surrounded by a scintillator detector array. The result, τμ = 2.197 013 (24) μs, is in excellent agreement with the previous world average. The new world average τμ = 2.197019(21) μs determines the Fermi constant GF = 1.166371(6) × 10^-5 GeV^-2 (5 ppm). Described …

    uiuc Repository record for A measurement of the mean life of the positive muon to a precision of 11 parts per million (opens in a new tab)

  9. Characterization and analysis development for the ALPHA-g barrel scintillator

    … principle for antimatter. It includes a scintillator detector called the Barrel Veto which will measure particle time of flight in an effort to distinguish antihydrogen annihilation products from cosmic ray background. A new analysis framework for BV data is presented. A small-scale …

    ubc Repository record for Characterization and analysis development for the ALPHA-g barrel scintillator (opens in a new tab) Download PDF for Characterization and analysis development for the ALPHA-g barrel scintillator (opens in a new tab)

  10. 222Rn measurements within the water phase of the SNO+ experiment

    The SNO+ experiment is a large multipurpose scintillator detector. In the first phase of the experiment, close monitoring is done to determine radioactivity background levels, in particular the monitoring of 222Rn as its presence can obscure or mimic physics data. This thesis focuses on a cryogenic …

    laurentian Repository record for 222Rn measurements within the water phase of the SNO+ experiment (opens in a new tab)

  11. A search for slow, lightly ionizing particles in cosmic rays

    … search was made using a small-area four-layer scintillator detector. Slow lightly ionizing particles created in cosmic ray interactions in the atmosphere which arrived within 13 ms of the shower front were searched for. In a live time of 2.55 x 10⁵ s 394,608 showers of two or more muons and …

    vt Repository record for A search for slow, lightly ionizing particles in cosmic rays (opens in a new tab)

  12. Development of a Scintillator Cluster Detector and Microcontroller Integrated Detector Circuit

    … on the development of a prototype cluster scintillator detector hermetically sealed in an aluminium housing for use in the HYPATIA array. The HYPATIA array will consist of GaGG and CeBr3(Ce) scintillators, however, this prototype uses four NaI(Tl) crystals to optimise the design and …

    whiterose Download PDF for Development of a Scintillator Cluster Detector and Microcontroller Integrated Detector Circuit (opens in a new tab)

  13. A radiotracer technique for in situ adsorbate measurements on smooth electrode surfaces

    … by pressing the electrode against a glass scintillator detector at the bottom of an electrochemical cell. Equations which account for the backscattering factor have been developed to calculate the surface packing density, $\Gamma$, of the adsorbate. Under current optimum conditions (when …

    uiuc Repository record for A radiotracer technique for in situ adsorbate measurements on smooth electrode surfaces (opens in a new tab)

  14. Charge Form Factor of the Neutron Through d vector(e vector, e'n) at Q(2) = 1.0(GeV/c)2

    … neutrons were detected in a segmented plastic scintillator detector in coincidence with the scattered electrons, which were tracked in High Momentum Spectrometer of the Hall C. The form factor was extracted by comparing the experimental beam--target asymmetry with full theoretical calculations …

    maryland Repository record for Charge Form Factor of the Neutron Through d vector(e vector, e'n) at Q(2) = 1.0(GeV/c)2 (opens in a new tab)

  15. Study of LaBr3 (Ce) detector response to high energy helium ions

    … radiation detection devices. Lanthanum Bromide scintillator detector (LaBe3: Ce) has been successfully used as a gamma spectrometer inside space crafts. However, data on its response to other particles such as charged particles remains limited. From a radiation protection perspective, it is …

    uoit Repository record for Study of LaBr3 (Ce) detector response to high energy helium ions (opens in a new tab)

  16. Low radon permeable gloves and laserball simulations for SNO+

    The SNO+ experiment is a multipurpose liquid scintillator detector whose rst goal is to measure neutrinoless double beta decay. This thesis describes two important components: simulations to optimize the time window for the prompt peak of an optical calibration source, the \laserball" and the …

    laurentian Repository record for Low radon permeable gloves and laserball simulations for SNO+ (opens in a new tab)

  17. Physical properties of liquid scintillators

    … studies at KamLAND in Japan using a liquid scintillator detector concluded the "Solar Neutrino Problem" by observing that the electron anti-neutrinos from the reactors around Japan were oscillating. The parameters of the oscillation matched those deduced from solar neutrinos, so additionally …

    hawaii Repository record for Physical properties of liquid scintillators (opens in a new tab)

  18. Calibration Hardware Research and Development for SNO+

    The SNO+ experiment is a kilo-tonne scale liquid scintillator detector located at SNOLAB in Sudbury, Ontario, Canada. As the successor to the Sudbury Neutrino Observatory, SNO+ will use linear alkylbenzene (LAB) as the scintillator to study neutrinos. During the solar phase, ux measurements will be …

    queens Repository record for Calibration Hardware Research and Development for SNO+ (opens in a new tab)

  19. A rapid, reliable methodology for radionuclide characterization of wet or dry stored used nuclear fuel via the application of algorithm-enhanced scintillator survey spectra

    … incorporated into an algorithm to post process scintillator detector data gathered from used nuclear fuel in a spent fuel pool or in air. An existing, novel post processing algorithm, SmartID, has been updated to extract and identify unique photopeaks represented in the underwater environment …

    gatech Repository record for A rapid, reliable methodology for radionuclide characterization of wet or dry stored used nuclear fuel via the application of algorithm-enhanced scintillator survey spectra (opens in a new tab)

  20. Measuring the ⁷Be Neutrino Flux From the Sun: Calibration of the Borexino Solar Neutrino Detector

    The Borexino solar neutrino detector is a real-time liquid scintillator detector designed to measure sub-MeV neutrinos. With its unprecedented level of radio-purity, Borexino is poised to provide the most precise measurements to-date of solar neutrino and geo-antineutrino fluxes. However, in order …

    vt Repository record for Measuring the ⁷Be Neutrino Flux From the Sun: Calibration of the Borexino Solar Neutrino Detector (opens in a new tab)

Page 1 of 4