Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 121 for “"Scleral"”.

  1. Ageing of Human Corneal and Scleral Collagen

    It is commonly accepted that, on ageing, the body’s proteins become structurally altered. One such protein predominating throughout the body is collagen. This long-lived protein forms a major part of the human cornea and sclera and it is within these tissues that the work of this thesis has …

    the-open-u Download PDF for Ageing of Human Corneal and Scleral Collagen (opens in a new tab)

  2. Multispectral scleral patterns for ocular biometric recognition

    … in the best recognition performance for the scleral patterns. Finally, the possibility of utilizing the scleral patterns in conjunction with the iris for recognizing ocular images exhibiting non-frontal gaze directions was established.

    wvu Repository record for Multispectral scleral patterns for ocular biometric recognition (opens in a new tab)

  3. Scleral Ultrastructure and Ocular Biomechanics in Experimental Myopia

    … Although axial elongation is a result of scleral remodeling, limited studies have characterized scleral ultrastructure and in vivo biomechanical properties. This dissertation evaluated scleral ultrastructure and ocular rigidity in infant rhesus monkeys during emmetropization and with …

    houston Repository record for Scleral Ultrastructure and Ocular Biomechanics in Experimental Myopia (opens in a new tab) Embargoed until 2028-08-01

  4. The Impact of a Scleral Lens on the Eye

    … gaps in understanding ocular effects of a scleral lens (SL), particularly in the composition of the fluid reservoir (FR) that bathes the cornea and the impact of the landing zone radius (LZR) on the eye. The purpose of this dissertation is to (1) identify and compare molecules in the FR to …

    houston Repository record for The Impact of a Scleral Lens on the Eye (opens in a new tab)

  5. The Human Limbal Shape and Scleral Lens Limbal Designs

    scleral lens scleral lens fitting limbus empirical fitting corneoscleral topography

    waterloo Repository record for The Human Limbal Shape and Scleral Lens Limbal Designs (opens in a new tab)

  6. Characterization and role of lumican in scleral extracellular matrix.

    Changes in scleral extracellular matrix, which is composed of proteins including glycoproteins, proteoglycans, and collagen, allow axial elongation of the eye resulting in myopia. Theoretically, changes in any scleral component could result in changes leading to increased axial length. The purpose …

    nodak Repository record for Characterization and role of lumican in scleral extracellular matrix. (opens in a new tab)

  7. Induced myopia in the guinea pig: scleral myofibroblasts and biomechanics

    … the effect of induced myopia on the in vivo scleral biomechanical properties and scleral cell populations in the guinea pig. Methods: One week old guinea pigs were monocularly deprived of form vision (MD) for 14 days. Cycloplegic refractive error was measured with an IR Optometer, and the …

    auckland-ms Repository record for Induced myopia in the guinea pig: scleral myofibroblasts and biomechanics (opens in a new tab)

  8. Ocular Effects of Scleral Lens Wear on Dry Eye Patients

    … the factors assessed. Keywords: dry eye disease. scleral contact lens, hydra-PEG, osmolarity, inflammadry, cornea

    waterloo Repository record for Ocular Effects of Scleral Lens Wear on Dry Eye Patients (opens in a new tab)

  9. Clinical performance and biological interactions during scleral contact lens wear

    Scleral lenses are among one of the best visual correction options nowadays. Despite the great augment on the peer-review literature related to scleral lenses in last few years, the impact of these lenses on the anterior ocular surface, as well as the comfort and visual enhancements over the …

    minho-thes Repository record for Clinical performance and biological interactions during scleral contact lens wear (opens in a new tab)

  10. An Investigation of Scleral Biomechanics and Myopia in the Mouse

    … is thought to be driven by remodeling of the scleral microstructure and altered biomechanics. Certain types of visual cues drive or protect against myopigenic axial elongation, coupling retinal signaling to scleral remodeling via a complex ”retinoscleral” signaling cascade. However, the key …

    gatech Repository record for An Investigation of Scleral Biomechanics and Myopia in the Mouse (opens in a new tab)

  11. Adding Personalized Wavefront Correction to a Scleral Lens After Lens Manufacture

    PURPOSE: To date, wavefront-guided scleral lenses have relied on the full-surface method (FSM) of manufacture, which requires the wavefront correction to be integrated into the design of a traditional scleral lens prior to lens manufacture. A novel patch-cutting method (PCM) of manufacture would …

    houston Repository record for Adding Personalized Wavefront Correction to a Scleral Lens After Lens Manufacture (opens in a new tab) Embargoed until 2028-05-01

  12. Comparing Scleral Lenses with Different Oxygen Permeabilities in a Keratoconus Population

    … in irregular astigmatism and visual distortion. Scleral lenses (SL) correct vision by vaulting the cornea with a thick lens (~300 μm) and fluid reservoir (FR, 100–200 μm). These lenses are typically made from high oxygen permeability (Dk ~100) materials; however, it is unclear whether hyper-Dk …

    houston Repository record for Comparing Scleral Lenses with Different Oxygen Permeabilities in a Keratoconus Population (opens in a new tab) Embargoed until 2028-05-01

  13. IN-VIVO SCLERAL AND CORNEAL BIOMECHANICS AS BIOMARKERS IN OPHTHALMIC PRACTICE

    As the relationship between biomechanical properties and abnormal tissue mechanics become more and more apparent in the field of ophthalmology, demand for in-vivo determination of biomechanical properties have also increased. While devices like the Ocular Response Analyser (ORA) have made the …

    nus Repository record for IN-VIVO SCLERAL AND CORNEAL BIOMECHANICS AS BIOMARKERS IN OPHTHALMIC PRACTICE (opens in a new tab) Download file for IN-VIVO SCLERAL AND CORNEAL BIOMECHANICS AS BIOMARKERS IN OPHTHALMIC PRACTICE (opens in a new tab)

  14. Scleral Shell Prostheses in New Zealand: Investigations to inform best practice

    … information to guide the clinical use of scleral shell prostheses (SSs) for the prosthetic rehabilitation of non-functional disfigured eyes (NFDEs) is sparse. Aim: This doctoral research integrated studies spanning epidemiology, practice patterns, lived experience, and clinical variables …

    auckland-ms Repository record for Scleral Shell Prostheses in New Zealand: Investigations to inform best practice (opens in a new tab)

  15. Tissue engineering a human conjunctiva-scleral model for in vitro testing

    … was to tissue engineer a human conjunctiva-scleral equivalent with very basic inflammatory components, using a combinatorial approach. The complete model would comprise an innervated, vascularised stroma, overlaid by a stratified epithelium within a bio-synthetic matrix. Matrices fabricated …

    ottawa-retro Repository record for Tissue engineering a human conjunctiva-scleral model for in vitro testing (opens in a new tab)

  16. Effects of Scleral Stiffness on Biomechanics of the Optic Nerve Head in Glaucoma

    … biomechanical properties of sclera, particularly scleral stiffness. However there is significant variability in reported stiffness data for human sclera. Therefore, our research goal was to measure the stiffness of human sclera and incorporate this information into finite element models of the …

    toronto-retro Repository record for Effects of Scleral Stiffness on Biomechanics of the Optic Nerve Head in Glaucoma (opens in a new tab)

Page 1 of 7