Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 53 for “"Screen-printed electrode"”
-
Graphene Screen-Printed Electrode for Wound-Related Biosensing
… data. This study seeks to explore a graphene screen-printed electrode (SPE) electrochemical biosensor that is non-invasive and efficient to constantly monitor wound healing in real time. This research study focuses specifically on the electrochemical detection of the Human Neutrophil Elastase …
-
Development of a microfluidic device with a screen printed electrode for studies on phase II metabolism
… in vitro and in vivo methodologies. Herein, screen printed electrodes (SPEs) were investigated as potent electrochemical tools with the aim of developing a microfluidic device with a SPE. The proposed chip could be used as a primary screening tool for phase II glutathione (GSH) adducts.The …
-
Development of a NiOxHy/chitosan-MWCNTs modified screen-printed electrode for dual detection of glucose and insulin
… in a chitosan matrix and deposited onto gold screen printed electrodes (SPEs) for the separate detection of glucose and insulin. The NiOxHy @MWCNTs composite was synthesized via hydrothermal treatment using nickel nitrate hexahydrate as the precursor and characterized by Raman spectroscopy, …
-
DNA based biosensors for environmental and medical applications
… DNA based biosensors were developed using screen printed electrode as transducers. Biosensors are defined as a self-containing integrated devices, capable of providing specific quantitative or semi-quantitative analytical information using a biological recognition element which is in …
-
Development of an Inhibition Based Biosensor for Arsenic (III)
… was determined to operate well with a screen printed electrode mediated with Cobalt- Phthalocyanine. Several different methods were considered when immobilizing the enzyme to the electrode surface. The preferred method was using glutaraldehyde with bovine serum albumin. It was then …
-
Desenvolvimento de biossensores eletroquímicos utilizando acetilcolinesterase visando identificar extratos e substâncias para o controle de formigas cortadeiras
… the enzyme acetylcholinesterase (AChE) in SPEs (screen printed electrode), using the layer-by-layer technique, using AuNPs-GSH (glutathione-decorated gold nanoparticles) and EDC reagents ( 1-ethyl-3- (3-dimethylaminopropyl) carbodiimide) and HOBt (Hydroxybenzotriazole) which establish the …
-
Label-free electrochemical aptasensor based on gold nanoparticles-modified screen-printed electrodes for detection of cytokines
… The aptasensor was fabricated based on a gold screen-printed electrode (GSPE) which was modified by electrochemically-deposited gold nanoparticles (AuNPs). The thiolatedaptamers were anchored on the surface of the aptasensor using gold-sulfur chemistry. Cyclic voltammetry (CV) and differential …
-
Development of an affinity sensor for the detection of Aflatoxin M1 in milk
… was successfully employed as the receptor for a screen printed HRP/TMB based immunosensor. Upon the analysis of milk it was observed that milk caused extensive interference and through a series of chemical extractions the interference was attributed to whey proteins in the milk with suspicion …
-
Photosystem II-based biosensor for the detection of explosive compounds
… methods, employing PS II immobilized on a screen-printed electrode as a part of electrical circuit; optical spectroscopy was used as a supplementary method. We have demonstrated that this electrochemical biosensor is capable of detecting explosives such as picric acid, TNT and tetryl. The …
-
Mimicking Human Drug Metabolic Reactions using Microfluidic Platforms
… of a microfluidic platform integrated with a screen-printed electrode and immobilised with drug metabolism enzymes for this purpose. To develop a methodology for mimicry of metabolic enzyme reactions in microfluidics, a well-understood enzyme transketolase (TK) was used as a model enzyme. A …
-
Electroanalytical sensors using lipophilic cyclodextrins
… size and charge caused some perturbation of the electrode response at a concentration of 10 mmol dm(^-3). An electrode comprising a plasticized biocompatible membrane matrix, TECOFLEX, with 2,6 didodecyl-β-cyclodextrin was incorporated in a flow injection analysis system and the response to …
-
Aminoxyl Catalyzed Electrochemical Ethanol Detection: Development of a New Breathalyzer Using Molecular Catalysis
… Our functional sensing element consists of a screen-printed electrode in which the graphene oxide-based working electrode is modified with aminoxyl derivatives, of which 4-hydroxy-2,2,6,6-tetramethylpiperidine 1-oxyl benzoate (TMB) was the most efficient derivative. Exposing this modified …
-
Electrochemical aptasensor for the detection of mycotoxins in food samples by experimental and computational methods
… constituents present in real samples, the carbon screen printed electrode (C-SPE) and carbon felt electrode (CFE) surfaces were modified with different nanomaterials such as silver nanoparticle (AgNPs), palladium nanoparticles (PdNPs), palladium doped boron nitride (PdNPs-BN) and titanium …
-
Portable electrochemical screening of drugs
… is the development of effective and accurate screening methodologies for the detection of illicit drugs. This is particularly true for new psychoactive substances (NPS), a group of compounds that mimic the effects of traditional drugs of abuse but with increased potency. Synthetic cannabinoids …
-
Biossegurança no controle da infecção hospitalar: desenvolvimento de imunossensor impedimétrico para detecção de Staphylococcus aureus em áreas críticas hospitalares
… on the surface of the transducer or the working electrode (screen-printed electrode - SPE), immobilization of protein A on SPEs modified with self-assembled monolayers (SAMs) of cystamine (CYS) and glutaraldehyde (GA); different incubation times and dilutions were used for both modifiers as for …
-
Detection of urinary extracellular vesicles using piezoelectric and electrochemical biosensors for point-of-care diagnosis of acute kidney diseases
… detection limit of 1600 particles/ml. Meanwhile, screen-printed electrode-based EIS sensors were also functionalised with anti-CD63 antibodies for detecting urinary exosomes. The sensors had a concentration-dependent signal response, achieving a detection limit of 1 × 104 particles/ml. After that, …
-
Characterization of carbon electrode surfaces development of biosensors for forensic DNA applications
… Electrochemistry-based biosensors that utilize screen-printed electrodes may provide a method to determine the number of DNA molecules and the length of those molecules in a single assay. This work aimed to create a biosensor by electrostatically loading TPOX oligonucleotides onto a carbon …
-
Desenvolvimento de imunossensor eletroquímico nanoestruturado descartável para detecção de SARS-CoV-2 em amostras ambientais
… immunosensors based on disposable screen-printed electrodes (SPEs) are a cheap, portable, sensitive and versatile option for clinical applications outside the laboratory environment and without the use of external reagents. In this context, in the present project a portable and …
-
Luminescent markers and labels in authentication and novel bioaffinity assays
… alternatives for expensive oxide-coated silicon electrodes for electrochemiluminoimmunoassays. Composite electrodes made of insulating cellulose derivatives or polystyrene with different conductive carbon materials are studied, and these materials are used to make screen-printed electrode chips. …
Page 1 of 3