Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 21 for “"Screw-Loosening"”.

  1. A Comparison of Dynamic Compression Plates and Locking Compression Plates Using Cantilever Bending in a Canine Ilial Fracture Model

    … being implant failure usually due to screw loosening from the cranial ilial segment. The high incidence of screw loosening has been attributed to poor quality bone in the cranial ilial segment. Ten pelves were harvested from healthy dogs euthanized for reasons unrelated to this study …

    guelph Repository record for A Comparison of Dynamic Compression Plates and Locking Compression Plates Using Cantilever Bending in a Canine Ilial Fracture Model (opens in a new tab)

  2. Evaluating toggle-out testing for pedicle screw failure prediction

    Pedicle screw loosening is a common failure mode in spinal instrumentation, particularly in osteoporotic bone, where cancellous strength averages 0.944 MPa compared to 1.5-7.8 MPa in healthy bone. This study evaluated toggle-out testing for predicting pedicle screw failure and examined how material …

    louisville Repository record for Evaluating toggle-out testing for pedicle screw failure prediction (opens in a new tab)

  3. A patient-specific approach for enhanced spinal fixation using a novel flexible pedicle screw

    Pedicle screw fixation has become the gold standard for spinal fixation surgery; however, current rigid pedicle screws are forced to fixate within a limited area. This limitation is driven by current rigid drilling instruments only being capable of drilling linear trajectories. This limited area of …

    texas Repository record for A patient-specific approach for enhanced spinal fixation using a novel flexible pedicle screw (opens in a new tab)

  4. Biomechanical investigation of the factors related to pedicle screw fixation strength

    … internal fixation devices. Fixation with pedicle screws is a well-established method providing spinal stability and deformity correction. However, reported rates of fixation failure because of screw loosening have become a major concern, especially with the appearance of new and more powerful …

    ets-quebec Download PDF for Biomechanical investigation of the factors related to pedicle screw fixation strength (opens in a new tab)

  5. Η θεραπευτική συμβολή των περιορισμένων αρθροδέσεων των οστών του καρπού

    … in 16% of our cases. Only one patient with screw loosening was revised. Partial wrist fusions affect wrist kinematics. The intracarpal fusions, gave the better results regarding pain, grip strength and range of motion, compared with midcarpal and radiocarpal fusions. Also we could not detect …

    greece Repository record for Η θεραπευτική συμβολή των περιορισμένων αρθροδέσεων των οστών του καρπού (opens in a new tab)

  6. Evaluating the Effect of the Protector Cap Technique for Castable Implant Abutments on Reverse Torque Values

    … reported regarding the implant abutment is screw loosening attributed to masticatory forces and insufficient preload torque. Purpose: The purpose of this study is to evaluate the differences in reverse torque value between UCLA abutments with no casting performed, UCLA abutments cast using a …

    loma-linda Repository record for Evaluating the Effect of the Protector Cap Technique for Castable Implant Abutments on Reverse Torque Values (opens in a new tab)

  7. The Effect of Different Screw Angulations on the Fracture Resistance of Implant Zirconia Single Crowns Made on Two Different Implant Platforms

    … to investigate the effect of different implant screw channel angulation and implant platform on the fracture resistance of zirconia abutments without artificial aging. Materials and Methods: ten implant replicas were mounted in printed resin block at 30 degrees angulation to vertical axis for …

    tamu Repository record for The Effect of Different Screw Angulations on the Fracture Resistance of Implant Zirconia Single Crowns Made on Two Different Implant Platforms (opens in a new tab)

  8. Integrated Investigations of Lumbar Spine Biomechanics, Implant Fixation, and Design for Additive Manufacturing under Physiologic Loading

    Spinal implant loosening and migration are significant concerns following the surgical treatment of musculoskeletal spinal disorders because of the complex and highly variable loading experienced in the spine. During post-operative rehabilitation, the mechanical interface between the vertebral bone …

    waterloo Repository record for Integrated Investigations of Lumbar Spine Biomechanics, Implant Fixation, and Design for Additive Manufacturing under Physiologic Loading (opens in a new tab)

  9. Complications associated with mandibular fixed complete arch prostheses based on implant distribution

    … groups on MISFCPs. Complications like screw loosening, prosthetic teeth fracture, prostheses fracture, pain etc. associated with MISFCPs were documented and then compared between implant distribution groups. Different variables like age, gender, opposing arch, cantilever occluding units …

    loma-linda Repository record for Complications associated with mandibular fixed complete arch prostheses based on implant distribution (opens in a new tab)

  10. Retrospective Study on the Influence of Splinted Crowns of Multiple Adjacent Implants

    … (20.8/13.0%), peri-implantitis (12.2/13.1%), and screw loosening (5.9/12.8%), while 3 failure causes (5-year estimates) were peri-implantits (1.8/1.3%), implant fracture/metal collar flowering (0.3/1.1%), and soft tissue encapsulation (0.1/0.2%). When 380 Lifecore implants were excluded, the …

    umn Repository record for Retrospective Study on the Influence of Splinted Crowns of Multiple Adjacent Implants (opens in a new tab)

  11. Miniplatten aus Titan zur Fixation von Gelenkfortsatzfrakturen des Unterkiefers: Evaluation des biomechanischen Verhaltens mittels der Finite-Elemente-Analyse

    … possible material failure in the plates and screws. In addition, the maximum principal strain in the bone was used to indicate potential bone areas that might be susceptible to bone resorption. All four plate designs (alpha, kappa, rhomboid, and trapezoidal) were tested under the same …

    lmu-germany Repository record for Miniplatten aus Titan zur Fixation von Gelenkfortsatzfrakturen des Unterkiefers: Evaluation des biomechanischen Verhaltens mittels der Finite-Elemente-Analyse (opens in a new tab)

  12. Factors Influencing Success of Zygomatic Implants Placed in an Institutional Setting: A Retrospective Study

    … fracture documented in 7 patients (31.8%), screw loosening in 2 patients (9.1%), and isolated prosthetic or multiunit abutment screw fractures in 2 patients (9.1%). Biologic complications included sinusitis in 4 patients (18.2%) and soft tissue complications in 4 patients (18.2%). Bivariate …

    tamu Repository record for Factors Influencing Success of Zygomatic Implants Placed in an Institutional Setting: A Retrospective Study (opens in a new tab) Embargoed until 2028-05-01

  13. Advancing Spine Surgery with Innovative Applications of Calcium Sulfate/Hydroxyapatite-Based Bone Substitutes

    Background Pseudarthrosis and pedicle screw loosening remain significant challenges in spinal surgery, often compromising clinical outcomes. Recombinant human bone morphogenetic protein-2 (rhBMP-2) is currently the primary FDA-approved osteoinductive factor for spinal fusion. However, its …

    qucosa-diss

  14. The effect of multiple tightening and untightening on abutment screw and driver head dimensions

    … and final prosthesis delivery, abutment screws often undergo repeated tightening and untightening cycles. These repeated manipulations may induce mechanical fatigue and dimensional alterations at the screw–driver interface, potentially affecting torque transmission, preload maintenance, …

    temple Repository record for The effect of multiple tightening and untightening on abutment screw and driver head dimensions (opens in a new tab)

  15. Fracture Strength of PEEK Hybrid Abutment Restored with Lithium Disilicate Crown

    … under a constant pressure. The abutments were screwed on their assigned implants at 35 Ncm twice with interval time of 10 minutes. The designed crown was used to mill and process 36 lithium disilicate crowns. Intaglio surface of crowns were etched using hydrofluoric acid; then, a coupling agent …

    buffalo Repository record for Fracture Strength of PEEK Hybrid Abutment Restored with Lithium Disilicate Crown (opens in a new tab)

  16. Verknöcherungsraten von Posterior Lumbar Interbody Fusion (PLIF) ohne Knochentransplantat bei degenerativ bedingter Instabilität der lumbalen Wirbelsäule

    … PEEK and 24% titanium). Complications such as screw loosening/adjacent-level disease were observed in 8%/8% in the PEEK group and in 0%/7% in the titanium group, respectively. Conclusion Transplantation of bone grafting material in PLIF-surgery using PEEK and titanium cages seems to have an …

    fu-berlin Repository record for Verknöcherungsraten von Posterior Lumbar Interbody Fusion (PLIF) ohne Knochentransplantat bei degenerativ bedingter Instabilität der lumbalen Wirbelsäule (opens in a new tab)

  17. Osteoporotic spine fixation : a biomechanical investigation

    … with osteoporosis) are loss of fixation due to loosening and adjacent segment effects. The objectives of this thesis were to compare existing techniques of osteoporotic spine fixation using in vitro biomechanical models and to investigate new surgical strategies, so as to provide information to …

    ubc Repository record for Osteoporotic spine fixation : a biomechanical investigation (opens in a new tab) Download PDF for Osteoporotic spine fixation : a biomechanical investigation (opens in a new tab)

  18. A review of clinical outcomes associated With dental implant treatment performed by residents in advanced training programs at the University of Minnesota School of Dentistry

    … luting cement fracture (SC 14%, FPD 47%), screw loosening (SC 12%, FPD 5%), screw fracture (SC 3%, FPD 2%), and porcelain fracture (SC 5%, FPD 1%). Complication and failure counts were provided for the remaining prosthetic types. Conclusions: Within the limitations of this review, and in …

    umn Repository record for A review of clinical outcomes associated With dental implant treatment performed by residents in advanced training programs at the University of Minnesota School of Dentistry (opens in a new tab)

  19. Influence of Morse taper angle and abutment material on preload development in dental implants

    … connection. Mechanical complications, such as screw loosening, component fracture, and micromovement, are influenced by factors including implant platform design, abutment geometry, and the efficiency of torque transfer into preload. Preload, the clamping force created by the elastic recovery …

    umn Repository record for Influence of Morse taper angle and abutment material on preload development in dental implants (opens in a new tab)

  20. CLINICAL AND PRECLINICAL STUDIES OF IMPLANTS WITH A MORSE-TAPER IMPLANT-ABUTMENT CONNECTION

    … implant fracture; abutment fracture; screw fracture; veneer fracture or chipping; metal framework fracture; abutment loosening; screw loosening; loss of access hole restoration. A total of 13 patients were treated with 41 implants. At the time of the last evaluation no implants failed, …

    milano Repository record for CLINICAL AND PRECLINICAL STUDIES OF IMPLANTS WITH A MORSE-TAPER IMPLANT-ABUTMENT CONNECTION (opens in a new tab)

Page 1 of 2