Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 6 of 6 for “"Second harmonic detection"”

  1. Study of Radiocarbon Detection By laser spectroscopy

    … of C¹⁴O₂, and it is shown that interference-free detection can be attained provided the gas sample is cooled to dry ice temperature. To achieve sufficient sensitivity we have developed a second harmonic detection scheme. As part of out optimisation procedure, the experimental and theoretical …

    mcmaster Repository record for Study of Radiocarbon Detection By laser spectroscopy (opens in a new tab)

  2. Spectroscopy of methane using a vertical cavity surface-emitting laser system with emphasis on development for portable applications

    … lasers are often used for atmospheric detection, the development of the vertical cavity surface-emitting laser (VCSEL) has allowed for an alternative source. The VCSEL exhibits several advantages over distributed feedback (DFB), edge-emitting lasers, especially in terms of power …

    alberta Repository record for Spectroscopy of methane using a vertical cavity surface-emitting laser system with emphasis on development for portable applications (opens in a new tab)

  3. Atmospheric Pollution Measurements with Tunable Lasers Employing Resonance Absorption

    … reported are based on either direct or second harmonic absorption techniques.</p> <p>A commercial CO/CO₂ line-tunable laser has been used to obtain useful criteria for air pollution monitoring via the direct absorption scheme. CO₂ laser absorption measurements on ozone at reduced …

    mcmaster Repository record for Atmospheric Pollution Measurements with Tunable Lasers Employing Resonance Absorption (opens in a new tab)

  4. Tomographic imaging of combustion zones using tunable diode laser absorption spectroscopy (TDLAS)

    … used here is known as wavelength modulation with second harmonic detection (abbr. WMS-2f) which uses the wavelength dependent absorbance information of two different spectroscopic transitions to determine temperature and concentration values. Traditionally, WMS-2f has generally been applied to …

    lsu-thes Repository record for Tomographic imaging of combustion zones using tunable diode laser absorption spectroscopy (TDLAS) (opens in a new tab) Restricted access

  5. Suitability of a short-external-cavity laser system within an open- path tunable diode laser absorption spectrometer (OP-tdlas)

    … employed Wavelength Modulation Spectroscopy with second harmonic detection. For the 1.60 µm system, the detection sensitivity over twelve hours, achieved from an indoor measurement equivalent to 355 ppm of CO2 over 475 m was 24x10-6 with a 1 second integration period. This corresponds to a CO2 …

    uvic Repository record for Suitability of a short-external-cavity laser system within an open- path tunable diode laser absorption spectrometer (OP-tdlas) (opens in a new tab)

  6. Studies of substituted hydrocarbon monolayers on platinum by means of auger electron spectroscopy with electrochemical calibration

    … by the conventional potential modulation/ second harmonic detection scheme of operation. The interface has been calibrated and an expression, for the collection efficiency of the retarding field analyzer, based on a layer model for the emitter, has been derived. In this way, absolute Auger …

    hawaii Repository record for Studies of substituted hydrocarbon monolayers on platinum by means of auger electron spectroscopy with electrochemical calibration (opens in a new tab)