Results 1 to 20 of 144 for “"Secondary Side"”

  1. Secondary-Side Impedance Control Strategies for Inductive Charging of Electric Vehicles

    … challenging design and control due to the dual-side operation. In response, this thesis proposes a number of novel secondary (vehicle-side) solutions to address the aforementioned issues. The first of which is known as active impedance control, whereby the impedance compression network and …

    auckland-ms Repository record for Secondary-Side Impedance Control Strategies for Inductive Charging of Electric Vehicles (opens in a new tab)

  2. Single-Stage Wireless Power Transfer System with Single-Switch Secondary Side Modulation

    … the loose coupling nature and separated primary/secondary side, achieving tight load regulation or implementing closed-loop control of output voltage/current is nontrivial in a wireless power transfer (WPT) system. Previously presented methods for regulating or controlling the output of a WPT …

    vt Repository record for Single-Stage Wireless Power Transfer System with Single-Switch Secondary Side Modulation (opens in a new tab)

  3. Secondary-Side Control in Dynamic Wireless Power Transfer Systems for Double-Sided Inductor-Capacitor-Capacitor and Series-Series Compensation Topologies

    … strategy. It proposes the integration of a secondary-side-only control under double-sided inductor-capacitor-capacitor (LCC) and series-series compensation topologies. A synchronous buck converter is used to step down the voltage to the maximum power transfer efficiency (MPTE) conditions and …

    durham Repository record for Secondary-Side Control in Dynamic Wireless Power Transfer Systems for Double-Sided Inductor-Capacitor-Capacitor and Series-Series Compensation Topologies (opens in a new tab)

  4. A THEORETICAL INVESTIGATION OF AEROSOL RETENTION WITHIN THE SECONDARY SIDE OF A STEAM GENERATOR UNDER A SGTR SEVERE ACCIDENT SEQUENCE IN A PWR NUCLEAR POWER PLANT

    … el generador de vapor (secuencias SGTR) están consideradas como contribuyentes del riesgo en reactores de agua a presión. Su relevancia radica en la potencial liberación de aerosoles radioactivos al medio ambiente en caso de accidente severo. Sin embargo, dichas partículas podrían quedar retenidas …

    upv Repository record for A THEORETICAL INVESTIGATION OF AEROSOL RETENTION WITHIN THE SECONDARY SIDE OF A STEAM GENERATOR UNDER A SGTR SEVERE ACCIDENT SEQUENCE IN A PWR NUCLEAR POWER PLANT (opens in a new tab)

  5. An Experimental Rig and Investigation of Steam Generator Tube Loading during Main Steam Line Break

    … vibrate when subjected to cross-flow of secondary side coolant, particularly in the U-bend region. Such tube vibrations result in fretting wear at tube supports, reducing the margin of safety against failure. In the event of a main steam-line- break, the superheated water In the steam …

    mcmaster Repository record for An Experimental Rig and Investigation of Steam Generator Tube Loading during Main Steam Line Break (opens in a new tab)

  6. Formation and Quantification of Corrosion Deposits in the Power Industry

    The presence of deposits on the secondary side of pressurized water reactor (PWR) steam generator systems is one of the main contributors to the high maintenance costs of these generators. Formation and transport of corrosion products formed due to the presence of impurities, metals and metallic …

    unt Repository record for Formation and Quantification of Corrosion Deposits in the Power Industry (opens in a new tab)

  7. Design resonant component for 380V/760V CLLC resonant converter

    … it can change the voltage value between primary side and secondary side. Nowadays, there are many applications from this converter, such as electrical vehicles, battery chargers and quality regulation. In this thesis, a 380V to 760V bidirectional CLLC resonant converter which is symmetric between …

    nanyang Repository record for Design resonant component for 380V/760V CLLC resonant converter (opens in a new tab)

  8. Single Stage Grid-Connected Micro-Inverter for Photovoltaic Systems

    … by allowing negative current from the grid-side through bidirectional switches placed on the secondary side of the transformer. Basically, the negative current discharges the MOSFET’s output capacitor thereby allowing turn-on of the primary switch under zero voltage. In order to optimize the …

    queens Repository record for Single Stage Grid-Connected Micro-Inverter for Photovoltaic Systems (opens in a new tab)

  9. Characterization of Iron Oxide Deposits Formed at Comanche Peak Steam Electric Station

    … impurities, metallic oxides and cations in the secondary side of the SG units result in formation of deposits. This research deals with the characterization of deposit samples collected from the two SG units (unit 1 and unit 2) at Comanche Peak Steam Electric Station (CPSES). X-ray diffraction …

    unt Repository record for Characterization of Iron Oxide Deposits Formed at Comanche Peak Steam Electric Station (opens in a new tab)

  10. High Slew Rate High-efficiency Dc-dc Converter

    … current compensator with nonlinear control in secondary side is proposed to eliminate the effect of opotocoupler, which reduces response times and simplifies the linear controller design in isolated DC-DC converters. A novel control method has been carried out in two-stage isolated DC-DC …

    ucf Repository record for High Slew Rate High-efficiency Dc-dc Converter (opens in a new tab)

  11. Design and Analysis of High Voltage to 48V DC-DC Converter Topologies for Automotive Applications

    … applications, below 60V DC operation is considered a low-voltage system, meeting safety protection requirements easily. Compared to current 12V systems, 48V systems increase efficiency by reducing currents, which allows for smaller wire sizes and higher power capability. Though 48V systems …

    chalmers Repository record for Design and Analysis of High Voltage to 48V DC-DC Converter Topologies for Automotive Applications (opens in a new tab)

  12. High Current Density Low Voltage Isolated Dc-dc Converterswith Fast Transient Response

    … the thermal management is challenging. Since the secondary-side conduction loss dominates the overall power loss in low-voltage high-current isolated dc-dc converters, a novel current tripler rectification topology is proposed. Theoretical analysis, comparison and experimental results verify that …

    ucf Repository record for High Current Density Low Voltage Isolated Dc-dc Converterswith Fast Transient Response (opens in a new tab)

  13. Topology Investigation and System Optimization of Resonant Converters

    … achieve zero-voltage-switching (ZVS) for primary side devices and zero-current-switching (ZCS) for the secondary side rectifiers. The switching loss is minimized. LLC is very attractive to overcome the issues of conventional circuits. However, challenges still remain. First of all, for low-voltage …

    vt Repository record for Topology Investigation and System Optimization of Resonant Converters (opens in a new tab)

  14. High power inductive wireless charger for PHEV and EV

    … is that the coupling coefficient of the primary side and secondary side windings is usually less than 0.1. Compensation networks are needed on both primary and secondary side to cancel the huge leakage inductances. Series resonant converter (SRC), with simply compensation networks, is widely …

    msu Repository record for High power inductive wireless charger for PHEV and EV (opens in a new tab)

  15. Matrix converter fed power electronic transformer with enhanced features.

    … HF transformer, the matrix converters on primary side of the transformer are switched such that natural commutation takes place in the leakage inductances. The overall efficiency of the PET is significantly improved. The commutation time is dependent on the value of leakage inductance. So, higher …

    umn Repository record for Matrix converter fed power electronic transformer with enhanced features. (opens in a new tab)

  16. The effect of steam generator tube plugging on its overall thermal performance - A Systems CFD-Based Study

    … as a fission product barrier between primary and secondary system. Material failure of the tube bundle barrier could therefore lead to a release of radioactive product into the secondary side. Several repair methods have been used to address tube leakage, with the most popular being tube plugging. …

    cape-town Repository record for The effect of steam generator tube plugging on its overall thermal performance - A Systems CFD-Based Study (opens in a new tab)

  17. High-Efficiency and High-Power Density DC-DC Power Conversion Using Wide Bandgap Devices for Modular Photovoltaic Applications

    … PV applications. The circuit configuration of secondary side is a proposed active-boost-rectifier, which merges a Boost circuit and a voltage-doubler rectifier. With implementation of the proposed double-pulse duty cycle modulation method, the active-boost-rectifier can not only serve for …

    vt Repository record for High-Efficiency and High-Power Density DC-DC Power Conversion Using Wide Bandgap Devices for Modular Photovoltaic Applications (opens in a new tab)

  18. Modeling strategy for EMI filter and flyback transformer

    … for common mode current flowing from the primary side to the secondary side. Different winding technologies have been invented and implemented to reduce the capacitance between the primary side and the secondary side. But the repeatability of the winding is still poor due to the fluctuations of …

    must-thes Repository record for Modeling strategy for EMI filter and flyback transformer (opens in a new tab)

  19. Magnetic Integration Techniques for Resonant Converters

    … shunt, unwanted high leakage inductance on the secondary side, and that integrated magnetics are not usually suitable for bidirectional converters such as CLLLC converters. Two new topologies (IT1 and IT2) for inserted-shunt integrated transformers are presented that do not need bespoke material …

    whiterose Repository record for Magnetic Integration Techniques for Resonant Converters (opens in a new tab)

  20. Design and Implementation of Overcurrent Protection Relays Test Bench

    … changeover switches installed on the primary and secondary side of the transformer. SEL-751A or three electromechanical CO-8 relays, one on each phase, can be selected as the main protection device on both sides of the transformer. There was only one industrial circuit breaker available in the …

    wvu Repository record for Design and Implementation of Overcurrent Protection Relays Test Bench (opens in a new tab)