Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 43 for “"Secondary Systems"”.

  1. Dynamic Response of Tuned Secondary Systems

    Light, flexible, "secondary" systems such as piping, penthouses and antenna towers are often attached to major structures. The purpose of this study is to investigate the dynamic response of secondary systems that are tuned to a natural frequency of the primary system.

    uiuc Repository record for Dynamic Response of Tuned Secondary Systems (opens in a new tab)

  2. Approximate Dynamic Response of Light Secondary Systems

    Made available in DSpace on 2014-12-10T22:22:02Z (GMT). No. of bitstreams: 1 7405645.pdf: 4574585 bytes, checksum: bbd0b042e0f154f5d2606031666b9e73 (MD5) Previous issue date: 1973

    uiuc Repository record for Approximate Dynamic Response of Light Secondary Systems (opens in a new tab)

  3. Seismic response analysis of multiply connected secondary systems

    … for seismic analysis of multiply supported secondary systems is developed. The formulation is based on the random vibration theory of structural systems subjected to correlated inputs at several points. The response of the secondary systems is expressed as a combination of the dynamic, …

    vt Repository record for Seismic response analysis of multiply connected secondary systems (opens in a new tab)

  4. Seismic analysis of multiply-supported MDOF secondary systems

    … analysis of Multi-Degree-Of-Freedom (MDOF) secondary system subjected to multiple-support excitations overestimates its response. It is recognized that the analysis overestimates the secondary system response because the dynamic characteristics of the combined Primary-Secondary (P-S) system …

    mcmaster Repository record for Seismic analysis of multiply-supported MDOF secondary systems (opens in a new tab)

  5. Nonnormality in the seismic response of primary-secondary systems

    … for a yielding primary structure and a linear secondary system (P-S) subjected to a normally distributed ground acceleration. The nonlinearity considered is bilinear hysteretic (BLH) yielding in the primary structure. The coefficient of excess (COE), which is a normalized fourth cumulant …

    rice Repository record for Nonnormality in the seismic response of primary-secondary systems (opens in a new tab)

  6. Seismic analysis of a class of secondary systems by generalized modes

    … study of the response of a class of linear secondary systems to earthquake excitations is made. The combined dynamical system studied consists of a single-degree-of-freedom oscillator attached to a continuous cantilever beam. The generalized differential equation governing free vibration is …

    rice Repository record for Seismic analysis of a class of secondary systems by generalized modes (opens in a new tab)

  7. A study of errors involved in seismic analysis of secondary systems.

    … of error in seismic modal analysis of primary-secondary coupled systems using the 'combination of modal properties' approach. Four sources of error are studied: non-classical damping, evaluation of modal properties of the combined system, combination of modal responses and response contribution …

    ottawa-retro Repository record for A study of errors involved in seismic analysis of secondary systems. (opens in a new tab)

  8. A Stochastic Model for Predicting Maximum Seismic Response of Light Secondary Systems

    Made available in DSpace on 2014-12-10T22:21:57Z (GMT). No. of bitstreams: 1 7317417.pdf: 4600683 bytes, checksum: 4f145921816fa8d334a308fe056afbe7 (MD5) Previous issue date: 1972

    uiuc Repository record for A Stochastic Model for Predicting Maximum Seismic Response of Light Secondary Systems (opens in a new tab)

  9. Exact modal synthesis methods for seismic analysis of primary and multiply supported secondary systems

    … . For seismic analysis of combined primary and secondary structures, such as a main structure supporting piping or other auxiliary system, the combined structure is divided into two substructures. The eigenproperties of these two substructures are then synthesized to obtain the eigenproperties …

    vt Repository record for Exact modal synthesis methods for seismic analysis of primary and multiply supported secondary systems (opens in a new tab)

  10. Ecological Interface Design for Turbine Secondary Systems in a Nuclear Power Plant: Effects on Operator Situation Awareness

    … on operator situation awareness (SA) for turbine secondary systems based on the Swedish Forsmark 3 boiling-water reactor nuclear power plant. A work domain analysis was performed on the turbine secondary systems yielding part-whole decomposition and abstraction hierarchy models. Information …

    waterloo Repository record for Ecological Interface Design for Turbine Secondary Systems in a Nuclear Power Plant: Effects on Operator Situation Awareness (opens in a new tab)

  11. INVESTIGATING THE DYNAMICS OF VOLATILE SULFUR COMPOUNDS FROM PRIMARY AND SECONDARY SYSTEMS IN WASTEWATER RESOURCE RECOVERY FACILITIES

    … of sewer conditions. Our investigations in secondary reactors have shown that MM was 2 to 3 order of magnitude higher than dissolved MM in primary effluent, revealing that the production of MM took place in the activated sludge process itself, and the stripping of MM from the feed was very …

    maryland Repository record for INVESTIGATING THE DYNAMICS OF VOLATILE SULFUR COMPOUNDS FROM PRIMARY AND SECONDARY SYSTEMS IN WASTEWATER RESOURCE RECOVERY FACILITIES (opens in a new tab)

  12. Seismic Response of Light Attachments to Buildings

    … to compute the maximum response of light secondary systems attached to buildings subjected to earthquakes. The method is derived by considering that a secondary system and its supporting primary structure form a single assembled system, and by applying a modified version of the response …

    uiuc Repository record for Seismic Response of Light Attachments to Buildings (opens in a new tab)

  13. Metering Secondary Water in Residential Irrigation Systems

    The use of residential secondary or dual water systems for irrigation purposes is common in the western United States where water supplies are scarce. While the use of non-potable water in secondary systems has successfully curtailed demands on potable systems, experience has shown that overall …

    utahstate Repository record for Metering Secondary Water in Residential Irrigation Systems (opens in a new tab)

  14. DESIGN AND ANALYSIS OF COGNITIVE MASSIVE MIMO NETWORKS WITH UNDERLAY SPECTRUM SHARING

    … massive multiple-input multiple-output (MIMO) systems have gained significant attention as a new network architecture to not only achieving unprecedented spectral and energy efficiencies, but also to alleviating propagation losses and inter-user/inter-cell interference. Therefore, massive MIMO …

    siu-theses Repository record for DESIGN AND ANALYSIS OF COGNITIVE MASSIVE MIMO NETWORKS WITH UNDERLAY SPECTRUM SHARING (opens in a new tab)

  15. Direct Method of Generating Floor Response Spectra for Structures under Earthquake Excitations at Multiple Supports

    … as seismic input in the safety assessment for secondary systems in the nuclear power industry. Efficient and accurate determination of FRS is crucial in the design of nuclear power facilities. It has been demonstrated that time history analysis can lead to large variabilities in the generation …

    waterloo Repository record for Direct Method of Generating Floor Response Spectra for Structures under Earthquake Excitations at Multiple Supports (opens in a new tab)

  16. Seismic Response of Structures with Flexible Floor Slabs by a Dynamic Condensation Approach

    … the floor slabs on the response of primary and secondary systems subjected to vertical ground motions. The calculated results clearly show that inclusion of the floor flexibility in the analytical model increases the design response significantly, especially when computing acceleration floor …

    vt Repository record for Seismic Response of Structures with Flexible Floor Slabs by a Dynamic Condensation Approach (opens in a new tab)

  17. To analyse measurements is to know!

    … efficiency. Traditionally, district heating systems are divided in three parts: heat generation, distribution, and substations, but from a system point of view the system border has to be put in the climate shell of the connected buildings. Heat supply and distribution have been contentiously …

    lund Repository record for To analyse measurements is to know! (opens in a new tab) Download PDF for To analyse measurements is to know! (opens in a new tab)

  18. Issues of seismic response and retrofit for critical substation equipment

    … the seismic hazard for transformer-bushing systems and different issues of the response and rehabilitation of transformers. The primary means of seismic mitigation investigated is the use of the Friction Pendulum System (FPS) bearings to seismically isolate transformers. This is done by …

    njit Repository record for Issues of seismic response and retrofit for critical substation equipment (opens in a new tab)

  19. Seismic response of acceleration-sensitive non-structural components mounted on irregular multi-storey reinforced concrete buildings

    … nonlinear finite element analyses of the primary-secondary systems were conducted to provide insight into the seismic response of the NSCs and to evaluate the accuracy of Eurocode 8 (EC8) predictions when the NSCs are attached to the flexible sides along the heights of the primary structures …

    birmingham Download PDF for Seismic response of acceleration-sensitive non-structural components mounted on irregular multi-storey reinforced concrete buildings (opens in a new tab)

Page 1 of 3