Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 37 for “"Secondary ions"”
-
SECONDARY IONS EMISSION FROM SI(100)
The secondary ion intensity of sputtered Si ions has been measured as a function or the emission energy using a calibrated mass analyzer. By assuming lhe Sigmund-Thompson energy distribution for neutrals, lhe ionisation probability R' is inferred. The transmission function or the secondary ion mass …
-
Secondary ions sputtered by low energy ion bombardment of copper and aluminum surfaces
We have bombarded Cu and Al surfaces with O2+ ions and measured the relative yields of secondary ions in the energy range from 50 to 500 eV. We have determined both the relative yield as a function of incident ion energy and the kinetic energy distributions of the ejected ions for selected incident …
-
Energy dispersed ion signatures at auroral and subauroral latitudes
… zone creates a significant population of thermal secondary ions. Acceleration mechanisms exist that are capable of energizing the thermal population to suprathermal energies (1 eV to 1 keV). Suprathermal ions escape into the magnetosphere and undergo "bounce" motion along magnetic field lines. …
-
Characterization of Nano-Environments by Hypervelocity Projectile Secondary Ion Mass Spectrometry
… this study was to explore the performance of a secondary ion mass spectrometry (SIMS) technique for probing nanovolumes. The variant of SIMS used involves bombardment with individual massive projectiles (Au400 and C60) at ∼ 1 keV/atom energy coupled with separate recording of the ionized ejecta …
-
Secondary ion emission from “super-efficient” events: prospects for surface mass spectrometry
… projectiles, result in the emission of multiple secondary ions. Such co-emissions imply that the ejecta originate from molecules co-located within the nano-volume perturbed by a single projectile impact. The relevance for the chemical analysis of nano-domains depends on the effectiveness of the …
-
Secondary ion emission under keV carbon cluster bombardment
Secondary ion mass spectrometry (SIMS) is a surface analysis technique capable of providing isotopic and molecular information. SIMS uses keV projectiles to impinge upon a sample resulting in secondary ion emission from nanometric dimensions. It is well documented that secondary ion emission is …
-
Nanoscale Properties of Block Copolymers, Perovskites and Boron Nitride Obtained by Near-field Scanning Optical Microscopy in the Infrared
… by PFIR, x-ray diffraction and time-of-flight secondary ions mass spectrometry. Lastly, phonon polaritons in hexagonal boron nitride were studied using SNOM. It was found that structures in the boron nitride can self-launch phonon polaritons. In addition, the effect of the adjacent layer of …
-
Secondary ion emission from single massive gold cluster impacts
Secondary ion mass spectrometry, SIMS, is one of the most versatile surface analytical techniques. The significant parameter determining the performance of SIMS is the secondary ion yield. Atomic projectiles, traditionally used in SIMS, are an inefficient method to desorb and generate secondary …
-
Application of coincidence ion mass spectrometry for chemical and structural analysis at the sub-micron scale
Surfaces can be probed with a variant of secondary ion mass spectrometry (SIMS) where the bombardment is with a sequence of single keV projectiles, each resolved in time and space, coupled with the separate record of the secondary ions (SIs) ejected from each projectile impact. The goal of this …
-
Mass spectrometry methods for imaging cellular lipids, organelles, and proteins
Lipids and their secondary metabolites function as energy storage molecules, structural components in cellular membranes, and messengers that can alter cellular function. Imaging the distributions of various lipid species within tissues and cells can yield insight into the mechanism by which lipids …
-
Secondary ion mass spectrometry of aromatic compounds in acidic mixtures
<p>Secondary ion mass spectrometry (SIMS) is an analytical method that can be used to obtain mass spectra of involatile/thermally labile compounds. The sensitivity of SIMS for organic compounds is enhanced if samples are first dissolved in an appropriate involatile liquid (or so-called matrix).</p> …
-
Short-time interdiffusion at polymer interfaces: A probe to study polymer motion
… labeling was reversed, i.e., the two end fractions were deuterated. Since, the total deuteration was equal in both the polymers, initially, the concentration of H and D segments was 0.5 at all depths in the HDH/DHD bilayer. Upon interdiffusion, if the polymer chains reptate, i.e., move ends …
-
The Self-Sustaining Processes in a Hollow Cathode to Produce a Steady Electron Emission
… our lives (i.e., manufacturing, communications, health care, energy). Performance improvements of the hollow cathode seem to have plateaued, though. The two major characteristics are that the electron emission of the cathode reaches a self-sustaining mode, ion bombardment of the low …
-
Caractérisation de la matière organique contenue dans les particules de la comète 67P/Churyumov-Gerasimenko par spectrométrie de masse avec l’instrument COSIMA de la sonde Rosetta
… Philae. Le spectromètre de masse d’ions secondaires à temps de vol, COSIMA (COmetary Secondary Ions Mass Analyzer), était l’un des instruments de l’orbiteur et a été conçu pour analyser in situ la composition chimique des particules solides éjectées de la comète 67P/C-G. L’objectif …
-
Characterization and Quantification of Biological Surfaces Using Cluster ToF-SIMS with the Event-By-Event Bombardment/Detection Mode
Cluster ToF-SIMS (time-of-flight secondary ion mass spectrometry) operated in the event-by-event bombardment/detection mode has been applied to: 1) evaluate and screen the manufacturing quality of step-wise prepared micropatterned biointerfaces; 2) quantify the binding density of Au nanoparticles …
-
Chemical Analysis of Cells and Tissues with Time-of-Flight Secondary Ion Mass Spectrometry
… biological cells and tissues with time-of-flight secondary ion mass spectrometry (ToF-SIMS) was explored. ToF-SIMS has the ability to obtain a mass spectrum with submicron spatial resolution for imaging and is extremely surface sensitive. ToF-SIMS for biological sample analysis is still an …
-
Low energy collisions of molecular ions with hydrogen, methane, and freon
Measurements of total cross sections for collision induced dissociation (CID), proton abstraction, and charge transfer have been made for the reactants H+3+H 2, He, and Ar CH+4+CD 4,H2 , and Ar, and CF+3 F++CF4,H2 and Ar for laboratory collision energies ranging from a few to 400 eV. Isotopic …
-
Characterization of Nanoscale Objects and Domains with Massive Cluster SIMS
Secondary ion mass spectrometry (SIMS) with a massive cluster projectile and run in the event-by-event bombardment/detection mode has been applied to perform nanoscale analysis. Massive clusters, specifically Au_(400)^(4+), at hypervelocity feature efficient production of multiple secondary ions …
-
Étude des interfaces électrode/électrolyte des batteries lithium-ion : cas de l'électrode à base de Li4Ti5O12
… sont privilégiées dans de nombreuses applications comme solution de stockage de l’énergie. Le composé Li4Ti5O12 (LTO) est une alternative au graphite qui demeure majoritairement utilisé comme matériau d’électrode négative dans les batteries Li-ion. Pour de potentielles applications à haute …
-
Application of imaging TOF-SIMS in cell and tissue research
… at extending the use of TOF-SIMS (time of flight secondary ion mass spectrometry) as an analytical tool in cell and tissue research. TOF-SIMS is a relatively new method that allows analysis of the chemical composition of sample surfaces. Originally, it was used for imaging the distribution of …
Page 1 of 2