Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 66 for “"Seismic Force Resisting System"”
-
Buckling restrained braced frames as a seismic force resisting system
The hazards of seismic activity on building structures require that engineers continually look for new and better methods of resisting seismic forces. Buckling restrained braced frames (BRBF) are a relatively new lateral force resisting system developed to resist highly unpredictable seismic forces …
-
Eccentrically braced steel frames as a seismic force resisting system
Braced frames are a common seismic lateral force resisting system used in steel structure. Eccentrically braced frames (EBFs) are a relatively new lateral force resisting system developed to resist seismic events in a predictable manner. Properly designed and detailed EBFs behave in a ductile …
-
Clt infill panels in steel moment resisting frames as a hybrid seismic force resisting system
This paper examines CLT-steel hybrid systems at three, six, and nine storey heights to increase seismic force resistance compared to a plain wood system. CLT panels are used as infill in a steel moment frame combining the ductility of a steel moment frame system with a stiffness and light weight of …
-
DEVELOPMENT OF A NOVEL SEISMIC FORCE RESISTING SYSTEM: CONTROLLED ROCKING MASONRY WALLS WITH ENERGY DISSIPATION ACCESSIBLE CONSTRUCTED ATOP A STEEL BASE
Conventional seismic design practices for reinforced masonry shear walls rely on ductility within the system, typically in the form of yielding of bonded reinforcement within the wall. While this is effective at dissipating energy, it comes at the expense of signi ficant damage in the plastic hinge …
-
Seismic mitigation technique for existing single storey steel CBF structures
… This thesis documents an evaluation of the seismic vulnerabilities of existing single storey concentrically braced frame steel structures. Focusing on the brace and brace connections, brittle failure of the connection was identified as a key concern. Use of a structural fuse element to input …
-
A State of the Art Review of Special Plate Shear Walls
… Plate Shear Walls (SPSW) are a relatively new Seismic Force Resisting System (SFRS). They were added to the AISC Seismic Provisions in 2005 and expanded on in the 2010 Provisions, but there is still research needed to fully flesh out the knowledge on SPSWs. This State of the Art Report …
-
Analysis of Brick Veneer on Concrete Masonry Wall Subjected to In-plane Loads
… factors such as tie spacing, tie stiffness, reinforcement, etc. Results indicate that some degrees of composite action exist; around 12 % to 37 % of the applied shear load is transferred to the brick veneer. Veneers should be isolated in their own plane from the seismic-force-resisting system. An …
-
Evaluation of New Seismic Performance Factors for Special Hybrid Coupled Core Wall Systems with Steel Coupling Beams
There are many seismic force-resisting systems in the structural world, and the Coupled Core Wall System has always been considered as one of the most effective systems to be used in structural seismic design, especially for mid- to high-rise buildings. Steel coupling beams are often used in the …
-
Δυναμική ανάλυση τρισδιάστατων μεταλλικών κατασκευών με χρήση του συστήματος Seesaw
The efficiency of the seesaw system when applied to low-rise 3-D steel structures is presented in this PhD Thesis. This efficiency is judged by several seismic response results coming from inelastic seismic time-history analyses of 2-, 5and 8-storey steel structures. These response results involve …
-
Kinematics and Preliminary FEMA P-695 Evaluation of the NewZ-BREAKSS Steel Boundary Frame with Buckling Restrained Brace Structural Fuses
… Braced Frames (BRBFs) have become a popular seismic force resisting system (SFRS) due to their high ductility and energy dissipation. However, BRBFs are also susceptible to large residual drifts, which can make repair difficult. Efforts to reduce the residual drift of BRBFs typically involve …
-
Developing a Plastic Hinge Model for RC Beams Prone to Progressive Collapse
… is to assess the modeling parameters for reinforced concrete (RC) beams specified in the GSA 2013. Three types of RC buildings located in high, moderate and low seismic zones in Canada are designed according to the 2010 edition of the National Building Code of Canada. They were designed to …
-
Seismic design and evaluation of self-centering modular rocking composite sandwich wall (SC-MRCSW) system
… and resilience. In order to enhance the seismic resilience and constructability, this thesis introduces a novel self-centering modular rocking composite sandwich wall (SC-MRCSW) system. SC-MRCSW system consists of steel plates in-filled with concrete, where the steel plates are tied using …
-
Design of gravity-load frames for seismic deformation demands in highrise concrete buildings with shear walls in Canada
… can be divided into two main components: the seismic-force resisting system (SFRS), responsible for withstanding seismic forces, and the remaining structure, often referred to as the gravity-load resisting frame (GLRF). Although the GLRF is not designed to resist seismic forces directly, it …
-
A Hybrid Mechanics-evolutionary Algorithm-derived Backbone Model for Unbonded Post-tensioned Concrete Block Shear Walls
… block (UPCB) shear walls are an effective seismic force resisting system due to their ability to contain expected damage attributed to their self-centering capabilities. A few design procedures were proposed to predict the in-plane flexural response of UPCB walls, albeit following only …
-
Seismic performance of controlled outrigger rocking wall system with different types of energy dissipation devices
Controlled Outrigger Rocking Wall (CORW) system is a novel earthquake resilient system which combines reinforced concrete wall with controlled rocking base hinge and outrigger system. At the end of the rocking base and the outrigger, different dampers are used to provide the supplemental energy …
-
Design and Experimental Evaluation of a Small-Scale Buckling Restrained Brace Analog
… Strongback braced frames (SBF) are a type of seismic force resisting system that aim to evenly distribute horizontal loads up the height of the building to mitigate this failure mechanism. Previous research shows that SBFs are a promising way to better design for seismic demands, but these …
-
Shake table Seismic Performance Assessment and Fragility Analysis of Lightly Reinforced Concrete Block Shear Walls
… on shake table tests on fully-grouted reinforced masonry (RM) shear walls. The test walls covers a range of design parameters to facilitate benchmarking, a thorough performance investigation, and calibration of numerical models as well as development of fragility curves within the context …
-
Combined gravity and lateral loading of light gauge steel framewood panel shear walls
… of steel frame/wood panel shear walls used as a seismic force resisting system have been developed. These methods, which can be used in conjunction with the 2005 NBCC, were based on the results of shear wall tests carried out using lateral loads alone. The research program was extended to …
-
Seismic analysis of steel frame wood panel shear walls
… use of steel frame/wood panel shear walls as a seismic force resisting system (SFRS) in residential and/or commercial buildings is expected to increase in the future. At the moment, in Canada, however, no specific guidelines in line with the seismic provisions of the National Building Code of …
-
Experimental and numerical investigations of Frameless cold form steel corrugated wall panels subjected to in-plane monotonic and cyclic loads
… novel application of CFSCWs, named as Frameless system, has been developed by BEHLEN Industries LP. The Frameless systems have been used as load bearing elements. However, no investigation has been conducted to assess the seismic performance of Frameless panels under axial and shear loads. Within …