Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 21 for “"Seismocardiogram"”.

  1. Noncontact Seismocardiogram Signal Detection Using Microwave Doppler Radar

    … research is to achieve non-contact detection of seismocardiogram (SCG), a representation of mechanical heart motion, using microwave Doppler radar system. The increase in demand for health monitoring requires robust, reliable, and accurate remote detection of cardiac signals. Due to its ability …

    gatech Repository record for Noncontact Seismocardiogram Signal Detection Using Microwave Doppler Radar (opens in a new tab)

  2. A Morphological Approach To Identify Respiratory Phases Of Seismocardiogram

    … been demonstrated that the signal morphology for seismocardiogram, the lower frequency band of chest accelerations, is different between inhale and exhale. For instance, systolic time intervals (STI), which provide a quantitative estimation of left ventricular performance, vary between inhale and …

    nodak Repository record for A Morphological Approach To Identify Respiratory Phases Of Seismocardiogram (opens in a new tab)

  3. Signal Processing Methods for Heart Rate Detection Using the Seismocardiogram

    … to use EMD and EWT for heart rate detection from Seismocardiogram (SCG) signal. Obtained result from applying SET to ECG signal is selected as our ground truth. Then, all three methods are used for heart rate detection from the SCG signal. The average error of SET method, EWT and EMD respectively …

    sask Repository record for Signal Processing Methods for Heart Rate Detection Using the Seismocardiogram (opens in a new tab)

  4. Signal Processing Methods for Heart Rate Detection Using the Seismocardiogram

    … to use EMD and EWT for heart rate detection from Seismocardiogram (SCG) signal. Obtained result from applying SET to ECG signal is selected as our ground truth. Then, all three methods are used for heart rate detection from the SCG signal. The average error of SET method, EWT and EMD respectively …

    sask Repository record for Signal Processing Methods for Heart Rate Detection Using the Seismocardiogram (opens in a new tab)

  5. Robust estimation of systolic time intervals using ballistocardiogram and seismocardiogram signals

    … obtained from the ballistocardiogram (BCG) and seismocardiogram (SCG) signals. New hardware to measure BCG was explored using a high bandwidth force plate and signal processing techniques which allowed for significant improvement in absolute measurements of pre-ejection period (PEP), and …

    gatech Repository record for Robust estimation of systolic time intervals using ballistocardiogram and seismocardiogram signals (opens in a new tab)

  6. Multilabel Classification of Valvular Heart Diseases from Seismocardiogram Signals Using Machine Learning

    Valvular heart disease (VHD) is one of the most prevalent diseases of the circulatory system. These conditions can seriously affect life and health, so early detection and treatment are important. Current techniques such as echocardiography, cardiac catheterization, and magnetic resonance imaging …

    qucosa-diss

  7. Artifact Noise Removal Techniques and Automatic Annotation on Seismocardiogram Using Two Tri-axial Accelerometers

    … to detect cardiac phases and events on Seismocardiogram (SCG) based on acceleration sensors. A Wi-Fi based data acquisition system and a framework on Matlab are developed to collect and process data while the subjects are in motion. The tests include eight volunteers who have no record …

    sask Repository record for Artifact Noise Removal Techniques and Automatic Annotation on Seismocardiogram Using Two Tri-axial Accelerometers (opens in a new tab)

  8. Analysis of seismocardiogram signals from healthy and unhealthy subjects using an accelerometer contact microphone

    … signatures can be captured accurately from the seismocardiogram (SCG) signals of a sensitive wearable accelerometer contact microphone (ACM) and validated by comparing with digital stethoscope phonocardiogram (PCG) signals. The ACM was placed on the pulmonic region of 18 subjects, 10 with no …

    gatech Repository record for Analysis of seismocardiogram signals from healthy and unhealthy subjects using an accelerometer contact microphone (opens in a new tab)

  9. Processing and Analysis of the Seismocardiogram to Enable Estimations of Blood Volume Decompensation Status

    … resuscitation. The features derived from the seismocardiogram were determined to be key in estimating hypovolemic status. The processing of this signal is still in the early stages, subject to many types of noise and requiring human oversight. The remainder of this work presents three …

    gatech Repository record for Processing and Analysis of the Seismocardiogram to Enable Estimations of Blood Volume Decompensation Status (opens in a new tab)

  10. Batteryless Membrane Sensors and Electronics for Monitoring of Cardiovascular Signals

    … monitor cardiovascular signals, such as pulse, seismocardiogram (SCG), and arterial strain. LC resonators are simple and easy-to-manufacture devices that can be monitored wirelessly without batteries. This technology allows for the creation of wearable and implantable devices usually used to …

    gatech Repository record for Batteryless Membrane Sensors and Electronics for Monitoring of Cardiovascular Signals (opens in a new tab)

  11. Enabling Wearable Hemodynamic Monitoring Using Multimodal Cardiomechanical Sensing Systems

    … To address this burden, in this work, we explore seismocardiogram-based wearable multimodal sensing techniques to estimate blood pressure and stroke volume. First, the performance of a multimodal, wrist-worn device capable of obtaining noninvasive pulse transit time measurements is used to …

    gatech Repository record for Enabling Wearable Hemodynamic Monitoring Using Multimodal Cardiomechanical Sensing Systems (opens in a new tab)

  12. ELECTRO-MECHANICAL DATA FUSION FOR HEART HEALTH MONITORING

    … (ECG), phonocardiogram (PCG), and seismocardiogram (SCG) signals, integrated with a microcontroller module with Bluetooth wireless connectivity. We also created a custom printed circuit board (PCB) to integrate all the sensors into a compact design. Then, flexible housing for the …

    rowan Repository record for ELECTRO-MECHANICAL DATA FUSION FOR HEART HEALTH MONITORING (opens in a new tab)

  13. Enabling Robust Online Processing of Physiological Signals Corrupted by External Vibrations

    … treatment. Previous research has shown that the seismocardiogram (SCG), which monitors cardiomechanical function noninvasively, can estimate hypovolemia progression more effectively than traditional vital signs. However, SCG signals are highly susceptible to vibration artifacts, which limits …

    gatech Repository record for Enabling Robust Online Processing of Physiological Signals Corrupted by External Vibrations (opens in a new tab)

  14. High precision accelerometer contact microphones for detection of mechano-acoustic cardiopulmonary signals

    … and processed to extract the phonocardiogram, seismocardiogram, lung sounds, and chest wall motion using data processing techniques, demonstrating the possibility of accurately capturing multiple types of acoustic and vibrational data from the body simultaneously using a single sensor. The …

    gatech Repository record for High precision accelerometer contact microphones for detection of mechano-acoustic cardiopulmonary signals (opens in a new tab)

  15. Machine Learning Across the Critical Care Continuum: Sensing, Prediction, Treatment, and Faithful Explanation

    … single-lead electrocardiogram and tri-axial seismocardiogram signals from a wearable chest patch. By combining amplitude, frequency, and baseline-wander respiratory surrogates with random forest regression, the model achieved an RMSE of 181.45 mL and Pearson correlation of 0.61 without …

    gatech Repository record for Machine Learning Across the Critical Care Continuum: Sensing, Prediction, Treatment, and Faithful Explanation (opens in a new tab)

  16. Modular and reconfigurable wireless e-tattoo platform for mobile physiological sensing

    … (SpO₂), heart rate, electrocardiogram (ECG), seismocardiogram (SCG) and body motion, also estimating continuous real-time blood pressure (BP). Moreover, I report a novel magnetic field repeater (feeding coil) on clothes by leveraging embroidery method and wireless capability. Utilizing this …

    texas Repository record for Modular and reconfigurable wireless e-tattoo platform for mobile physiological sensing (opens in a new tab)

  17. Digital Biomarker Discovery for Non-Invasive Health Monitoring with Acoustic and Vibration Signals

    … estimation of stroke volume based on wearable seismocardiogram and phonocardiogram measurements taken from the sternum. Overall, this dissertation presents novel frameworks leveraging wearable vibration and acoustic measurements for knee joint and cardiovascular health assessment. Once verified …

    gatech Repository record for Digital Biomarker Discovery for Non-Invasive Health Monitoring with Acoustic and Vibration Signals (opens in a new tab)

  18. Flexible and stretchable piezoelectric bio-integrated sensors and energy harvesters based on polyvinylidene fluoride (PVDF)

    Piezoelectricity is a phenomenon that electric energy is generated in a certain material when the material is subjected to mechanical load, and vice versa. Piezoelectric devices with high stretchability and flexibility for bio-integrated applications, including skin-conformal strain sensors and …

    texas Repository record for Flexible and stretchable piezoelectric bio-integrated sensors and energy harvesters based on polyvinylidene fluoride (PVDF) (opens in a new tab)

  19. Multi-sensor signal processing methods for home monitoring of cardiovascular and respiratory diseases

    Cardiovascular and respiratory diseases are leading contributors of health problems in the world. The existing home monitoring devices for cardio-respiratory health are obtrusive and incapable of measuring a broad range of physiological parameters. In this context, this research investigated …

    gatech Repository record for Multi-sensor signal processing methods for home monitoring of cardiovascular and respiratory diseases (opens in a new tab)

  20. Cuffless blood pressure monitoring technologies based on pulse transit time

    Cuffless sensing techniques for monitoring pulse transit time (PTT) to estimate blood pressure was proposed. Developing such techniques is imperative to providing an at-home solution that is more convenient than current monitoring systems. PTT, or the time interval for an arterial pulse wave to …

    gatech Repository record for Cuffless blood pressure monitoring technologies based on pulse transit time (opens in a new tab)

Page 1 of 2