Showing 1 to 20 of 21 for “"Seismocardiogram"”.
-
Noncontact Seismocardiogram Signal Detection Using Microwave Doppler Radar
… research is to achieve non-contact detection of seismocardiogram (SCG), a representation of mechanical heart motion, using microwave Doppler radar system. The increase in demand for health monitoring requires robust, reliable, and accurate remote detection of cardiac signals. Due to its ability …
-
A Morphological Approach To Identify Respiratory Phases Of Seismocardiogram
… been demonstrated that the signal morphology for seismocardiogram, the lower frequency band of chest accelerations, is different between inhale and exhale. For instance, systolic time intervals (STI), which provide a quantitative estimation of left ventricular performance, vary between inhale and …
-
Signal Processing Methods for Heart Rate Detection Using the Seismocardiogram
… to use EMD and EWT for heart rate detection from Seismocardiogram (SCG) signal. Obtained result from applying SET to ECG signal is selected as our ground truth. Then, all three methods are used for heart rate detection from the SCG signal. The average error of SET method, EWT and EMD respectively …
-
Signal Processing Methods for Heart Rate Detection Using the Seismocardiogram
… to use EMD and EWT for heart rate detection from Seismocardiogram (SCG) signal. Obtained result from applying SET to ECG signal is selected as our ground truth. Then, all three methods are used for heart rate detection from the SCG signal. The average error of SET method, EWT and EMD respectively …
-
Robust estimation of systolic time intervals using ballistocardiogram and seismocardiogram signals
… obtained from the ballistocardiogram (BCG) and seismocardiogram (SCG) signals. New hardware to measure BCG was explored using a high bandwidth force plate and signal processing techniques which allowed for significant improvement in absolute measurements of pre-ejection period (PEP), and …
-
Multilabel Classification of Valvular Heart Diseases from Seismocardiogram Signals Using Machine Learning
Valvular heart disease (VHD) is one of the most prevalent diseases of the circulatory system. These conditions can seriously affect life and health, so early detection and treatment are important. Current techniques such as echocardiography, cardiac catheterization, and magnetic resonance imaging …
-
Artifact Noise Removal Techniques and Automatic Annotation on Seismocardiogram Using Two Tri-axial Accelerometers
… to detect cardiac phases and events on Seismocardiogram (SCG) based on acceleration sensors. A Wi-Fi based data acquisition system and a framework on Matlab are developed to collect and process data while the subjects are in motion. The tests include eight volunteers who have no record …
-
Analysis of seismocardiogram signals from healthy and unhealthy subjects using an accelerometer contact microphone
… signatures can be captured accurately from the seismocardiogram (SCG) signals of a sensitive wearable accelerometer contact microphone (ACM) and validated by comparing with digital stethoscope phonocardiogram (PCG) signals. The ACM was placed on the pulmonic region of 18 subjects, 10 with no …
-
Processing and Analysis of the Seismocardiogram to Enable Estimations of Blood Volume Decompensation Status
… resuscitation. The features derived from the seismocardiogram were determined to be key in estimating hypovolemic status. The processing of this signal is still in the early stages, subject to many types of noise and requiring human oversight. The remainder of this work presents three …
-
Batteryless Membrane Sensors and Electronics for Monitoring of Cardiovascular Signals
… monitor cardiovascular signals, such as pulse, seismocardiogram (SCG), and arterial strain. LC resonators are simple and easy-to-manufacture devices that can be monitored wirelessly without batteries. This technology allows for the creation of wearable and implantable devices usually used to …
-
Enabling Wearable Hemodynamic Monitoring Using Multimodal Cardiomechanical Sensing Systems
… To address this burden, in this work, we explore seismocardiogram-based wearable multimodal sensing techniques to estimate blood pressure and stroke volume. First, the performance of a multimodal, wrist-worn device capable of obtaining noninvasive pulse transit time measurements is used to …
-
ELECTRO-MECHANICAL DATA FUSION FOR HEART HEALTH MONITORING
… (ECG), phonocardiogram (PCG), and seismocardiogram (SCG) signals, integrated with a microcontroller module with Bluetooth wireless connectivity. We also created a custom printed circuit board (PCB) to integrate all the sensors into a compact design. Then, flexible housing for the …
-
Enabling Robust Online Processing of Physiological Signals Corrupted by External Vibrations
… treatment. Previous research has shown that the seismocardiogram (SCG), which monitors cardiomechanical function noninvasively, can estimate hypovolemia progression more effectively than traditional vital signs. However, SCG signals are highly susceptible to vibration artifacts, which limits …
-
High precision accelerometer contact microphones for detection of mechano-acoustic cardiopulmonary signals
… and processed to extract the phonocardiogram, seismocardiogram, lung sounds, and chest wall motion using data processing techniques, demonstrating the possibility of accurately capturing multiple types of acoustic and vibrational data from the body simultaneously using a single sensor. The …
-
Machine Learning Across the Critical Care Continuum: Sensing, Prediction, Treatment, and Faithful Explanation
… single-lead electrocardiogram and tri-axial seismocardiogram signals from a wearable chest patch. By combining amplitude, frequency, and baseline-wander respiratory surrogates with random forest regression, the model achieved an RMSE of 181.45 mL and Pearson correlation of 0.61 without …
-
Modular and reconfigurable wireless e-tattoo platform for mobile physiological sensing
… (SpO₂), heart rate, electrocardiogram (ECG), seismocardiogram (SCG) and body motion, also estimating continuous real-time blood pressure (BP). Moreover, I report a novel magnetic field repeater (feeding coil) on clothes by leveraging embroidery method and wireless capability. Utilizing this …
-
Digital Biomarker Discovery for Non-Invasive Health Monitoring with Acoustic and Vibration Signals
… estimation of stroke volume based on wearable seismocardiogram and phonocardiogram measurements taken from the sternum. Overall, this dissertation presents novel frameworks leveraging wearable vibration and acoustic measurements for knee joint and cardiovascular health assessment. Once verified …
-
Flexible and stretchable piezoelectric bio-integrated sensors and energy harvesters based on polyvinylidene fluoride (PVDF)
Piezoelectricity is a phenomenon that electric energy is generated in a certain material when the material is subjected to mechanical load, and vice versa. Piezoelectric devices with high stretchability and flexibility for bio-integrated applications, including skin-conformal strain sensors and …
-
Multi-sensor signal processing methods for home monitoring of cardiovascular and respiratory diseases
Cardiovascular and respiratory diseases are leading contributors of health problems in the world. The existing home monitoring devices for cardio-respiratory health are obtrusive and incapable of measuring a broad range of physiological parameters. In this context, this research investigated …
-
Cuffless blood pressure monitoring technologies based on pulse transit time
Cuffless sensing techniques for monitoring pulse transit time (PTT) to estimate blood pressure was proposed. Developing such techniques is imperative to providing an at-home solution that is more convenient than current monitoring systems. PTT, or the time interval for an arterial pulse wave to …