  1. Development of methods for in situ testing of response times of resistance temperature detectors in commercial pressurized water reactors

    … and evaluate suitable methods for in situ testing of the response time of RTD's.</p><p>Three testing procedures were used in laboratory experiments: (1) loop current step response (LCSR) test, (2) self-heating test, and (3) plunge test. The LCSR test involved a step change in the internal …

    ut-knoxville Repository record for Development of methods for in situ testing of response times of resistance temperature detectors in commercial pressurized water reactors (opens in a new tab)

  2. Sulphide self-heating: moisture content and sulphur formation

    Spontaneous or self-heating of sulphides can occur under certain conditions of moisture, temperature and oxygen concentration. This can lead to emission of toxic gases such as SO2 and if uncontrolled, to ignition. Research has established that self-heating divides into three stages: A (below 100 …

    mcgill Repository record for Sulphide self-heating: moisture content and sulphur formation (opens in a new tab)

  3. Fatigue and self-heating study of NiTi-based alloys fabricated with laser powder bed fusion

    … material is very costly in terms of material and testing time. Thus, a rapid prediction method for fatigue properties has recently beendeveloped, known as the self-heating method, with the aim of providing a solution to reduce characterization costs. This experimental self-heating test associated …

    ohiolink Repository record for Fatigue and self-heating study of NiTi-based alloys fabricated with laser powder bed fusion (opens in a new tab)

  4. In-situ response time testing of platinum resistance thermometers in nuclear power plants

    … A method called the loop current step response test was employed for quantitative evaluation of the response time of temperature sensors after installation in a plant. The application of this method on resistance thermometers is based on monitoring a temperature transient that results from a …

    ut-knoxville Repository record for In-situ response time testing of platinum resistance thermometers in nuclear power plants (opens in a new tab)

  5. Experimental and Theoretical Studies of Kinetics and Quality Parameters to Determine Spontaneous Combustion Propensity of U.S. Coals

    … and techniques have been developed for studying self-heating of coal. Each of the methods has its unique characteristics and index for assessing the propensity of self-ignition. However, all the reasonable candidate factors causing spontaneous combustion could not be examined thoroughly by any …

    wvu Repository record for Experimental and Theoretical Studies of Kinetics and Quality Parameters to Determine Spontaneous Combustion Propensity of U.S. Coals (opens in a new tab)

  6. Phenomenological Studies of Fires on Recycling Materials

    … m high in line with the UK regulations. The fire tests ranged in masses between 3 tonnes and 18 tonnes of material. The piles were tested in both a fully open condition and within a bunker. The material was ignited on the surface and measures using a bespoke thermocouple array. A series if deep …

    cent-lancashire Repository record for Phenomenological Studies of Fires on Recycling Materials (opens in a new tab)

  7. De l’apport des mesures de champs de température sous sollicitations cycliques pour la caractérisation et la modélisation des propriétés en fatigue des assemblages soudés

    Le dimensionnement en fatigue à grand nombre de cycles de joints soudés nécessite la caractérisation expérimentale des paramètres d'influences liés au chargement mais également aux spécificités du joint soudé (géométrie, contraintes résiduelles, défauts liés au procédé, parachèvement). Face au …

    star-france Repository record for De l’apport des mesures de champs de température sous sollicitations cycliques pour la caractérisation et la modélisation des propriétés en fatigue des assemblages soudés (opens in a new tab)