Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 13 of 13 for “"Semi-rigid connection"”.
-
A study of semi-rigid connections between longspan joists and columns
… on the restraint values of beam-column connections, the beam is often over designed by failing to take advantage of partial continuity. If the degree of restraint of a beam-column connection can be determined, the optimum beam moment can be derived and then an optimum or economic beam …
-
Analysis of Semi-Rigid Connections Subject to Fire Loads in a Steel Framework
… analysis of a 2-bay by 2-storey structure when a semi-rigid connection is exposed to thermal loads typical of those that might be encountered during a real fire. The structural fire analysis is principally based on incorporating moment-rotation-temperature data for the connection, as found in …
-
The behaviour of composite beams with partial interaction at elevated temperatures.
… influence of slip at the interface. The shear connection is modelled as a linking medium characterised by an assumed force-slip relationship. Semi-rigid connection characteristics are also incorporated as zero length spring elements connected to the steel beam and reinforced concrete slab. A …
-
Efficient Progressive Collapse Analysis for Robustness Evaluation and Enhancement of Steel-Concrete Composite Buildings
… is proposed, accounting for column buckling, semi-rigid connection and membrane action of slab. The accuracy of ePCA is validated by comparing with experimental results from the literature, at both on component level and system level. Application of ePCA on a three-dimensional building system …
-
Serviceability Design of Long-Span Timber Beams Considering Semi-Rigid Beam-Column Connections
… restraint provided by real beam-column connections. This simplification often results in overly conservative designs, inefficient material use, and underutilisation of structural capacity. Addressing this gap, this thesis investigates the influence of semi-rigid connection stiffness on …
-
Numerical analysis and investigation of composite semi-rigid connections
<p>Semi-rigid connections possessing a certain degree of moment resistance and stiffness provide versatility for the construction of a building frame. In particular, composite connections can be used in frames to improve efficiency in design with minimal additional detailing. In order for …
-
The strength of biaxially loaded beam-columns in flexibly connected steel frames.
… were connected using 'simple' bolted steelwork connections. The aim was to investigate the effect of the inherent rotational stiffness (semi-rigid characteristics) of such connections on the behaviour of steel frames in which the columns were loaded biaxially and were not restricted to in-plane …
-
The response of non-sway steel framed structures with semi-rigid connections.
… The findings have been used to develop improved semi-rigid design methods. Details of the experimental results of five frames are discussed and reported. A variety of joint types were tested, each type of joint exhibited some degree of moment and rota- tional stiffness, leading to frame responses …
-
NONLINEAR ANALYSIS OF STEEL BUILDINGS WITH RC SHEAR WALLS USING IMPROVED APPLIED ELEMENT METHOD
… without considering initial imperfections and semi-rigid connection behavior. These two features should not be ignored as they have considerable implications on the accuracy in simulating the resistance and stability of real steel structures. In addition, there is no application of iAEM for …
-
Progressive-Failure Analysis of Steel Building Structures under Abnormal Loads
… of members. The stiffness degradation of semirigid connections is modeled by a moment-rotation relationship with four parameters. Having the proposed nonlinear model, a generic member stiffness matrix is derived taking into account elastic-plastic bending, shearing and axial deformations. …
-
LOWER LIMB ASYMMETRY AND LOADING IN INDIVIDUALS WITH UNILATERAL TRANSFEMORAL AMPUTATIONS WITH A LIFETIME OF OSSEOINTEGRATED PROSTHESIS USE
… by the prosthesis. In addition, the indirect and semi-rigid connection of the socket to the body may increase interlimb asymmetries, as well as lead to pain and discomfort on the residual limb. Recent innovations have introduced a bone-anchored or osseointegrated (OI) implant which connects the …
-
Bracing Requirements for Multi-column Systems with Nonuniform Stiffness and Semi-rigid Connections
… simulates the column as two perfectly-straight rigid members pin-connected at ends, it neglects the column's flexibility and initial curvature as well as the stiffness of end connections. As a consequence, the pertinent research and standards are limited to multiple columns with pin ends and may …
-
Redução da resposta dinâmica de torres metálicas treliçadas autoportantes submetidas à ação do vento através de amortecedores de ligação
… do sistema. A inserção destes elementos reduz a rigidez e aumenta o amortecimento da ligação e, por consequência, reduz a frequência natural de vibração da estrutura. Assim, é necessário determinar a rigidez e o amortecimento ótimos que diminuam os efeitos da ação do vento na torre. Portanto, …