Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 17 of 17 for “"Semi-rigid joints"”.
-
Behaviour of columns in sub-frames with semi-rigid joints.
… limited subassemblages with flexible beans and semi-rigid beam to column connections was studied using a computer program in which the finite element method was employed in a non-linear analysis which accounts for the presence of semi-rigid connections and the inelastic behaviour of frames. The …
-
Experimental analysis of king-post truss with semi-rigid joints
… strong and stiff, but it is not perfectly rigid. The effect of non-rigidity of joints in resisting bending and thrust are investigated in this paper. The purpose of this study is to determine the rotation and slip of truss members relative to plywood gussets which influence the moment, …
-
Semi-rigid joints for moment-resisting steel framed seismic-resisting systems
This thesis describes the development of new semi-rigid joints for moment-resisting steel framed (MRSF) seismic-resisting systems. Intended as the weak link in the seismic-resisting system, in accordance with a strong column, weak joint philosophy, the joints and systems were designed and detailed …
-
Advanced Analysis of Cold-Formed Steel Portal Frames Having Semi-rigid Joints
… members. For CFS portal frames, eaves and apex joints are semi-rigid, as they are formed through brackets with folded edge stiffeners, fastened to the webs of channel sections. This type of construction is still not being fully exploited due to the practical difficulties in evaluating the …
-
Υπολογισμός μεταλλικών φορέων με ημιάκαμπτες συνδέσεις
This dissertation examines the behaviour of semi-rigid joints and its purpose is twofold: it intends to provide a reason for their existence, and examine their effects on the structural response of steel structures of which these joints form part. The chosen approach is hinged on six chapters. The …
-
Modelling and analysis of composite structures with semi-rigid connections
… are either designed as pinned or designed as rigid. Recent research has shown that semi-rigid joint behaviour may be achieved in composite joints by considering only a small amount of reinforcement over the connections. However due to the lack of design provisions and a simple and effective …
-
Non-linear analysis of infilled frames.
… columns, the aspect ratio for the infill, the semi-rigid joints and the condition of the frame-infill interfaces (co-efficient of friction and lack of fit). It is concluded that simple and economical design approaches can be established for frames with infilling walls.
-
Load-support conditions and computerized test apparatus for wood pallets
… that a pallet functions as a frame with semi-rigid joints whose function differs with the width of the support. A 53 percent reduction in centerline deflection was observed if support width was increased from 1 to 4 inches.
-
The behaviour of composite beam-to-column flush end plate connections using blind bolts
… of cruciform composite beam-to-column joints connected using blind bolts were tested under static and cyclic loading. The test results were used to obtain the load-displacement characteristics of the connection, failure modes and strain development. The test results demonstrated …
-
Frame behaviour with semi-rigid connections.
… been conducted on the behaviour of fully and semi-rigidly connected multistorey steel frames. Many topics have been addressed, current design approaches examined and new design methods proposed to allow for such effects based upon a first order linear elastic analysis, which is the most …
-
Giunti semirigidi con barre incollate per strutture lignee = Ductile moment-resistant steel-timber connections with glued-in bars
… chiave (modalità di rottura, resistenza ultima, rigidezza e capacità rotazionale) à ̈ stato proposto e validato attraverso unâ€TMampia campagna sperimentale. A tale scopo il metodo per componenti, originariamente proposto per giunti semi-rigidi in acciaio, à ̈ stato adattato per modellare i …
-
Semi-rigid behaviour of plane timber structures
… of structural frames, to either assume that the joints are pinned or rigid. In fact the real behaviour of a joint is neither pinned nor rigid, and lies somewhere between the pinned and rigid assumption. This is referred to as the semi-rigid behaviour. Semi-rigidity not only refers to the …
-
Simulation of the structural behaviour of steel-framed buildings in fire.
… zero length, have been introduced to represent semi-rigid joints. These degrade in stiffness and strength with rise in temperature and are represented by any specified moment-rotation-temperature relationship. Unloading from an inelastic state has been modelled for both the steel members and …
-
Extended end-plate connections for lnk-column joints of eccentrically braced frames
… for designing EEP connections for link-column joints are proposed.</p> <p>Because of the severe inelastic behaviour of the shear links, their proper modelling is important for the accurate analysis of an EBF. In the second phase of this research, a simple yet effective link element model is …
-
Průmyslová hala
Cílem bakalářské práce je návrh a posouzení ocelové nosné kontrukce průmyslové haly. Příčná vazba je tvořena rámem s náběhy o rozpětí 30 m a půdorysné délce 72 m. Výška ve středu vazby je 10,3 m a osová vzdálenost těchto vazeb je 6 m. Použítým materiálem je ocel S355. Součástí je posouzení …
-
SEMI-RIGID BEAM-TO-BEAM COMPOSITE JOINT FOR LONG SPAN COMPOSITE FLOOR BEAM
… investigation on beam-to-beam composite joints (BBCJs) to evaluate their structural properties such as the rotational stiffness and moment resistance, and the test results were compared with the analytical predictions based on the component method in Eurocode 4. According to these …
-
Sportovní - tenisová hala
Cílem bakalářské práce by návrh a posouzení ocelové nosné konstrukce sportovní -tenisové haly v Litovli. Příčná vazba je tvořena dvakrát lomeným rámem ve tvaru mansardy o rozpětí 24 m a půdorysné délce 50 m. Výška ve středu vazby je 12 m a osová vzdálenost těchto vazeb je 5 m. Použitým materiálem …